Additional file 1 of The Tie-2 agonist PMC-403 inhibits endothelial damage induced by e-cigarette vapor or LPS
Authors/Creators
- 1. Hannover Medical School
-
2.
German Center for Lung Research
-
3.
Justus-Liebig-Universität Gießen
- 4. Berlin Institute of Health at Charité - Universitätsmedizin Berlin
- 5. Charité - University Medicine Berlin
-
6.
Medizinische Hochschule Hannover
- 7. University Hospital of Zurich
Description
Supplementary Material 1: Supplemental Data 1: E-cigarette vapor application in isolated ventilated and perfused mouse lungs. To isolate the lung/heart block, mice were deeply anesthetized with ketamine (100 mg/kg body weight, i.p.) and xylazine (20 mg/kg body weight, i.p.), following anticoagulation with heparin (2,500 U/kg body weight). A tracheostomy was performed for intubation, and the mice were ventilated with a normoxic gas mixture (21% O₂, 5.3% CO₂, balanced with N₂) using a piston pump (Minivent Type 845, Hugo Sachs Elektronik, March-Hugstetten, Germany). Ventilation settings included a tidal volume of 10 μl/g body weight, a respiratory rate of 90 breaths/min (60 breaths/min during direct e-cigarette vapor inhalation), and a positive end-expiratory pressure (PEEP) of 3 cm H₂O. While maintaining ventilation, the chest was opened, and the block of lung and heart was dissected. Perfusion was initiated via a catheter inserted into the pulmonary artery using a peristaltic pump (ISM834A V2.10, Ismatec, Wertheim, Germany). The perfusate consisted of Krebs-Henseleit buffer [120 mM NaCl, 4.3 mM KCl, 1.1 mM KH₂PO₄, 2.4 mM CaCl₂, 1.3 mM MgCl₂, 13.3 mM glucose, and 5% (w/v) hydroxyethyl amylopectin; molecular weight 200,000 Da]. Following removal of the lung-heart block from the thoracic cavity, the preparation was freely suspended from a scale to monitor weight changes. A catheter was inserted into the left atrium to collect the outflow perfusate. The outflow pressure was maintained at 2 cm H₂O. Pulmonary arterial pressure, venous pressure, ventilation pressure, and lung weight were continuously monitored throughout the experiment. Nicotine-containing e-cigarette vapor (ECVnic) was generated using the "eVic Primo Mini" battery pack (Joyetech®) and the "Eleaf Melo 3" clearomizer (0.5 Ω, 30 W; Riccardo®, Riccardo Retail GmbH, Neubrandenburg, Germany). Vapor was drawn into a perfusor syringe via a vacuum pump using normoxic air. The puffing protocol involved four 5-second puffs (20 seconds total). ECVnic was applied to the isolated lung via the inspiratory tube using a syringe driver, mimicking normal ventilation. During each application, the expiratory tube was closed until the target inspiratory volume was reached, then reopened to release the vapor. This process lasted approximately 2 seconds and was repeated 150 times over a 5-minute period. In total, seven ECVnic application cycles were performed at 10-minute intervals. Normoxic ventilation was maintained throughout. Control experiments followed the same protocol but used normoxic gas without ECVnic. 6 µg/ml LPS, 10 µg/ml of the Tie2-agonist PMC-403, or their combination was added to the perfusate 5 minutes before ECVnic inhalation. After ECVnic inhalation, transvascular fluid filtration (endothelial permeability) was assessed under hydrostatic stress by increasing venous pressure from 2 to 12 cm H₂O for 8 minutes ("pressure challenge"), using the capillary filtration coefficient (Kfc) as previously described [23]. Two pressure challenges were performed before the start of PMC-403 application to confirm the quality and stability of the lung preparation. The entire experiment lasted approximately 4 hours. To assess edema formation, net lung weight gain following a hydrostatic challenge was measured as an indicator of fluid retention. Lungs were suspended from a force transducer, and weight gain was calculated as the difference between the baseline and 5 minutes after each pressure challenge. Additionally, wet-to-dry lung weight ratios were determined using the left lungs. Wet weight was recorded immediately after the experiment, and dry weight was measured after a 48-hour drying period at 65°C.
Additional details
Identifiers
Related works
- Is supplement to
- 10.1186/s12931-026-03928-4 (DOI)
Dates
- Created
-
September 29, 2026
- Issued
-
September 26, 2026
- Updated
-
September 29, 2026