Automatic Bone Removal in CBCT Scans of the Body Trunk: Thorax, Abdomen, and Pelvis
Authors/Creators
Description
Abstract Purpose To evaluate a fully automated bone removal software for cone beam computed tomography (CBCT) of the thorax, abdomen, and pelvis, enhancing vascular visualization by eliminating bone interference and improving diagnostic quality. Material and Methods 1035 CBCT scans from adults age 66.5 ± 11.9 18–87 years (mean ± std min–max) across nine centers were retrospectively analyzed, divided into training ( n = 855, 515 abdomen, 229 pelvis, 111 thorax) and testing ( n = 180, 60 for each region, 114 male, 53 female, 13 unknown). Manual bone segmentation was performed using ITK-SNAP. A modified 3D U-Net was trained and clinically evaluated through multireader analysis using ordinal scales from 1 (perfect) to 4 (not usable) bone subtraction (B-rating) and erosion of non-target structures (V-rating) in addition to a vessel assessment (VA-rating), categorizing the subtracted image as "better" (1), "same" (2), or "worse" (3). Quantitative metrics include Sørensen–Dice coefficient and intersection over union (IoU). Results The software demonstrated high accuracy with a B-rating of 1.01 ± 0.07 and a V-rating of 1.02 ± 0.13, indicating minimal erosion of non-target structures. A VA-rating of 1.0 ± 0 suggests an improved vessel assessment and the depiction of contrast material deposition, enhancing the diagnostic quality of CBCT images. Quantitative analysis closely matched the manual expert delineation (Sørensen–Dice coefficient 0.95 ± 0.02, IoU of 0.9 ± 0.03). Conclusion The software provides robust, fully automated bone removal in CBCT scans. This technology may enhance vascular system visualization without compromising non-target structures, potentially improving the accuracy and efficiency of interventional and diagnostic radiology procedures. Graphical Abstract
Additional details
Identifiers
- OpenAlex
- W7118283644
- PMID
- 41495251
- URL
- https://link.springer.com/10.1007/s00270-025-04293-3
Funding
- Medizinische Hochschule Hannover (MHH)
Dates
- Issued
-
January 6, 2026
References
- Deng, K., Liu, C., Ma, R., Sun, C., Wang, X.-. m ., Ma, Z.-. t ., & Sun, X.-. l . (2009). Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography. Clinical Radiology, 64(5), 534–541. https://doi.org/10.1016/j.crad.2009.01.007
- Kumamaru, K. K., Hoppel, B. E., Mather, R. T., & Rybicki, F. J. (2010). CT Angiography: Current Technology and Clinical Use. Radiologic Clinics of North America, 48(2), 213–235. https://doi.org/10.1016/j.rcl.2010.02.006
- Sommer, W. H., Johnson, T. R., Becker, C. R., Arnoldi, E., Kramer, H., Reiser, M. F., & Nikolaou, K. (2009). The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography Angiography. Investigative Radiology, 44(5), 285–292. https://doi.org/10.1097/rli.0b013e31819b70ba
- Park, D. Y., Kim, H.-C., Chung, J. W., Hur, S., Kim, M., Lee, M., Jae, H. J., & Zhang, Q. (2017). Cone-beam computed tomography with automated bone subtraction in preoperative embolization for pelvic bone tumors. PLOS ONE, 12(4), e0175907. https://doi.org/10.1371/journal.pone.0175907
- Hinrichs, J. B., Renne, J., Hoeper, M. M., Olsson, K. M., Wacker, F. K., & Meyer, B. C. (2016). Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance. European Radiology, 26(11), 4064–4071. https://doi.org/10.1007/s00330-016-4280-z
- Tacher, V., Radaelli, A., Lin, M., & Geschwind, J.-F. (2015). How I Do It: Cone-Beam CT during Transarterial Chemoembolization for Liver Cancer. Radiology, 274(2), 320–334. https://doi.org/10.1148/radiol.14131925
- Wacker, F. K., Meissner, O. A., & Meyer, B. C. (2009). C-Arm-CT zur Planung und Steuerung extrahepatischer Embolisationen. Der Radiologe, 49(9), 842–847. https://doi.org/10.1007/s00117-009-1864-5
- Tacher, V., Lin, M., Bhagat, N., Abi Jaoudeh, N., Radaelli, A., Noordhoek, N., Carelsen, B., Wood, B. J., & Geschwind, J.-F. (2013). Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization. Journal of Visualized Experiments, (82). https://doi.org/10.3791/50795
- Miyayama, S., Yamashiro, M., Hashimoto, M., Hashimoto, N., Ikuno, M., Okumura, K., Yoshida, M., & Matsui, O. (2013). Identification of Small Hepatocellular Carcinoma and Tumor-feeding Branches with Cone-beam CT Guidance Technology during Transcatheter Arterial Chemoembolization. Journal of Vascular and Interventional Radiology, 24(4), 501–508. https://doi.org/10.1016/j.jvir.2012.12.022
- Wang, X., Shah, R. P., Maybody, M., Brown, K. T., Getrajdman, G. I., Stevenson, C., Petre, E. N., & Solomon, S. B. (2011). Cystic Artery Localization with a Three-dimensional Angiography Vessel Tracking System Compared with Conventional Two-dimensional Angiography. Journal of Vascular and Interventional Radiology, 22(10), 1414–1419. https://doi.org/10.1016/j.jvir.2011.02.022
- Maschke, S. K., Hinrichs, J. B., Renne, J., Werncke, T., Winther, H. M. B., Ringe, K. I., Olsson, K. M., Hoeper, M. M., Wacker, F. K., & Meyer, B. C. (2018). C-Arm computed tomography (CACT)-guided balloon pulmonary angioplasty (BPA): Evaluation of patient safety and peri- and post-procedural complications. European Radiology, 29(3), 1276–1284. https://doi.org/10.1007/s00330-018-5694-6
- Schulz, B., Kuehling, K., Kromen, W., Siebenhandl, P., Kerl, M. J., Vogl, T. J., & Bauer, R. (2012). Automatic Bone Removal Technique in Whole-Body Dual-Energy CT Angiography: Performance and Image Quality. American Journal of Roentgenology, 199(5), W646–W650. https://doi.org/10.2214/ajr.12.9176
- Lauric, A., Heller, R. S., Schimansky, S., & Malek, A. M. (2014). Benefit of Cone‐Beam CT Angiography in Visualizing Aneurysm Shape and Identification of Exact Rupture Site. Journal of Neuroimaging, 25(1), 56–61. https://doi.org/10.1111/jon.12120
- Becker, L. S., Gutberlet, M., Maschke, S. K., Werncke, T., Dewald, C. L. A., von Falck, C., Vogel, A., Kloeckner, R., Meyer, B. C., Wacker, F., & Hinrichs, J. B. (2020). Evaluation of a Motion Correction Algorithm for C-Arm Computed Tomography Acquired During Transarterial Chemoembolization. CardioVascular and Interventional Radiology, 44(4), 610–618. https://doi.org/10.1007/s00270-020-02729-6
- Wang, Z., Hansis, E., Chen, R., Duran, R., Chapiro, J., Sheu, Y. R., Kobeiter, H., Grass, M., Geschwind, J.-F., & Lin, M. (2016). Automatic bone removal for 3D TACE planning with C-arm CBCT: Evaluation of technical feasibility. Minimally Invasive Therapy & Allied Technologies, 25(3), 162–170. https://doi.org/10.3109/13645706.2015.1129970
- Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006). User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. NeuroImage, 31(3), 1116–1128. https://doi.org/10.1016/j.neuroimage.2006.01.015
- Ronneberger, O., Fischer, P., & Brox, T. (2015). U-Net: Convolutional Networks for Biomedical Image Segmentation. In Lecture Notes in Computer Science (pp. 234–241). Springer International Publishing. https://doi.org/10.1007/978-3-319-24574-4_28
- Çiçek Ö, Abdulkadir A, Lienkamp SS, Brox T, Ronneberger O. 3D U-Net: learning dense volumetric segmentation from sparse annotation. ArXiv160606650 Cs [Internet]. 2016 [cited 2017 May 27]; http://arxiv.org/abs/1606.06650. Accessed 27 May 2017.
- He K, Zhang X, Ren S, Sun J. Delving deep into rectifiers: surpassing human-level performance on ImageNet classification. ArXiv150201852 Cs [Internet]. 2015 [cited 2017 March 10]; http://arxiv.org/abs/1502.01852. Accessed 10 March 2017.
- Kingma DP, Ba J. Adam: a method for stochastic optimization. ArXiv14126980 Cs [Internet]. 2014 [cited 2017 Mar 21]; http://arxiv.org/abs/1412.6980. Accessed 21 March 2017
- de Baere, T., Ronot, M., Chung, J. W., Golfieri, R., Kloeckner, R., Park, J.-W., Gebauer, B., Kibriya, N., Ananthakrishnan, G., & Miyayama, S. (2022). Initiative on Superselective Conventional Transarterial Chemoembolization Results (INSPIRE). CardioVascular and Interventional Radiology, 45(10), 1430–1440. https://doi.org/10.1007/s00270-022-03233-9
- Desai, H., Yu, H., Ohana, E., Gunnell, E. T., Kim, J., & Isaacson, A. (2018). Comparative Analysis of Cone-Beam CT Angiogram and Conventional CT Angiogram for Prostatic Artery Identification Prior to Embolization. Journal of Vascular and Interventional Radiology, 29(2), 229–232. https://doi.org/10.1016/j.jvir.2017.09.020
- Maschke, S. K., Werncke, T., Becker, L. S., Dewald, C. L. A., Meine, T. C., Olsson, K. M., Fuge, J., Hoeper, M. M., Wacker, F. K., Meyer, B. C., & Hinrichs, J. B. (2022). The Value of C-Arm Computed Tomography in Addition to Conventional Digital Subtraction Angiography in the Diagnostic Work-up of Patients with Suspected Chronic Thromboembolic Pulmonary Hypertension: An Update of 300 Patients. Academic Radiology, 29, S1–S10. https://doi.org/10.1016/j.acra.2020.06.039
- Yan Kang, Engelke, K., & Kalender, W. A. (2003). A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data. IEEE Transactions on Medical Imaging, 22(5), 586–598. https://doi.org/10.1109/tmi.2003.812265
- Wang, L. I., Greenspan, M., & Ellis, R. (2006). Validation of bone segmentation and improved 3-D registration using contour coherency in CT data. IEEE Transactions on Medical Imaging, 25(3), 324–334. https://doi.org/10.1109/tmi.2005.863834