Implant impingement during internal rotation after reverse shoulder arthroplasty. The effect of implant configuration and scapula anatomy: A biomechanical study
Additional details
Identifiers
Funding
- DePuy Synthes
- 2012-0006
Dates
- Issued
-
March 2016
References
- Boileau, P., Watkinson, D. J., Hatzidakis, A. M., & Balg, F. (2005). Grammont reverse prosthesis: Design, rationale, and biomechanics. Journal of Shoulder and Elbow Surgery, 14(1), S147–S161. https://doi.org/10.1016/j.jse.2004.10.006
- Chou, J., Malak, S. F., Anderson, I. A., Astley, T., & Poon, P. C. (2009). Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: Range of motion and risk of scapular notching. Journal of Shoulder and Elbow Surgery, 18(3), 354–359. https://doi.org/10.1016/j.jse.2009.01.015
- de Wilde, L. F., Poncet, D., Middernacht, B., & Ekelund, A. (2010). Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis. Acta Orthopaedica, 81(6), 719–726. https://doi.org/10.3109/17453674.2010.538354
- The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency
- Guery, J., Favard, L., Sirveaux, F., Oudet, D., Mole, D., & Walch, G. (2006). Reverse Total Shoulder Arthroplasty. The Journal of Bone & Joint Surgery, 88(8), 1742–1747. https://doi.org/10.2106/jbjs.e.00851
- Gutiérrez, S., Levy, J. C., Frankle, M. A., Cuff, D., Keller, T. S., Pupello, D. R., & Lee, W. E. (2008). Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. Journal of Shoulder and Elbow Surgery, 17(4), 608–615. https://doi.org/10.1016/j.jse.2007.11.010
- Kontaxis, A., & Johnson, G. R. (2009). The biomechanics of reverse anatomy shoulder replacement – A modelling study. Clinical Biomechanics, 24(3), 254–260. https://doi.org/10.1016/j.clinbiomech.2008.12.004
- Langohr, G. D. G., Giles, J. W., Athwal, G. S., & Johnson, J. A. (2015). The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion. Journal of Shoulder and Elbow Surgery, 24(6), 972–979. https://doi.org/10.1016/j.jse.2014.10.018
- Lévigne, C., Boileau, P., Favard, L., Garaud, P., Molé, D., Sirveaux, F., & Walch, G. (2008). Scapular notching in reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 17(6), 925–935. https://doi.org/10.1016/j.jse.2008.02.010
- Levy, J. C., Virani, N., Pupello, D., & Frankle, M. (2007). Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. The Journal of Bone and Joint Surgery. British Volume, 89-B(2), 189–195. https://doi.org/10.1302/0301-620x.89b2.18161
- Levy, J., Frankle, M., Mighell, M., & Pupello, D. (2007). The Use of the Reverse Shoulder Prosthesis for the Treatment of Failed Hemiarthroplasty for Proximal Humeral Fracture. The Journal of Bone & Joint Surgery, 89(2), 292–300. https://doi.org/10.2106/jbjs.e.01310
- Levy, J. C., Everding, N. G., Gil, C. C., Stephens, S., & Giveans, M. R. (2014). Speed of recovery after shoulder arthroplasty: a comparison of reverse and anatomic total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 23(12), 1872–1881. https://doi.org/10.1016/j.jse.2014.04.014
- Middernacht, B., De Roo, P.-J., Van Maele, G., & De Wilde, L. F. (2008). Consequences of Scapular Anatomy for Reversed Total Shoulder Arthroplasty. Clinical Orthopaedics & Related Research, 466(6), 1410–1418. https://doi.org/10.1007/s11999-008-0187-6
- Nyffeler, R. W., Werner, C. M. L., Simmen, B. R., & Gerber, C. (2004). Analysis of a retrieved Delta III total shoulder prosthesis. The Journal of Bone and Joint Surgery. British Volume, 86-B(8), 1187–1191. https://doi.org/10.1302/0301-620x.86b8.15228
- Raiss, P., Rettig, O., Wolf, S., Loew, M., & Kasten, P. (2007). Das Bewegungsausmaß der Schulter und des Ellenbogens bei Alltagsbewegungen in der 3D-Bewegungsanalyse. Zeitschrift für Orthopädie und Unfallchirurgie, 145(04), 493–498. https://doi.org/10.1055/s-2007-965468
- Simovitch, R. W., Zumstein, M. A., Lohri, E., Helmy, N., & Gerber, C. (2007). Predictors of Scapular Notching in Patients Managed with the Delta III Reverse Total Shoulder Replacement. The Journal of Bone & Joint Surgery, 89(3), 588–600. https://doi.org/10.2106/jbjs.f.00226
- Failures of the reverse prosthesis: identifying the problems
- Sirveaux, F., Favard, L., Oudet, D., Huquet, D., Walch, G., & Mole, D. (2004). Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. The Journal of Bone and Joint Surgery. British Volume, 86-B(3), 388–395. https://doi.org/10.1302/0301-620x.86b3.14024
- Stevens, C. G., Struk, A. M., & Wright, T. W. (2014). The functional impact of bilateral reverse total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 23(9), 1341–1348. https://doi.org/10.1016/j.jse.2013.12.012
- Functional internal rotation after shoulder arthroplasty: a comparison of anatomic and reverse shoulder arthroplasty
- Grammont's reverse shoulder prosthesis for rotator cuff arthropathy. A retrospective study of 32 cases
- Virani, N. A., Cabezas, A., Gutiérrez, S., Santoni, B. G., Otto, R., & Frankle, M. (2013). Reverse shoulder arthroplasty components and surgical techniques that restore glenohumeral motion. Journal of Shoulder and Elbow Surgery, 22(2), 179–187. https://doi.org/10.1016/j.jse.2012.02.004
- Reverse total shoulder arthroplasty: a review of results according to etiology
- Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis
- Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., Werner, F. W., & Buchholz, B. (2005). ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and hand. Journal of Biomechanics, 38(5), 981–992. https://doi.org/10.1016/j.jbiomech.2004.05.042
Citations
- Gibian, J. T., Blum, E., Keener, J. D., & Zmistowski, B. M. (2026). Decreasing body mass index and surgery on the nondominant shoulder, not implant factors, are the only independent predictors of internal rotation following reverse shoulder arthroplasty. Seminars in Arthroplasty: JSES, 36(1), 151495. https://doi.org/10.1053/j.sart.2025.08.001
- Fleet, C. T., Carroll, P., Johnson, J. A., & Athwal, G. S. (2025). The effect of sequentially increased polyethylene constraint on impingement in reverse shoulder arthroplasty: a biomechanical investigation. Journal of Shoulder and Elbow Surgery, 34(10), 2466–2479. https://doi.org/10.1016/j.jse.2024.12.049
- Skrede, A., Fagerhaug Dalen, A., Inge Hellevik, A., Stavdahl, Ø., & Bye, R. T. (2025). Toward Generality of a Framework for Quantifying Biomechanical Stability: Demonstration on the Ankle. IEEE Access, 13, 21723–21733. https://doi.org/10.1109/access.2025.3535406
- Besnard, M., Samargandi, R., Abualross, O., & Berhouet, J. (2025). The Influence of the Joint Volume on the Prevention of Impingement and Elbow-at-Side Rotations: Could the 36 mm Sphere with an Inferior Offset of 2 mm Be the New Gold Standard?. Journal of Clinical Medicine, 14(7), 2324. https://doi.org/10.3390/jcm14072324
- Pastor, M.-F., Nebel, D., Becker, L. M., Hurschler, C., Karrer, A. A., & Smith, T. (2024). Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study. European Journal of Orthopaedic Surgery & Traumatology, 34(5), 2353–2364. https://doi.org/10.1007/s00590-024-03898-7
- Kim, H. M., Nguyen, M., & Groneck, A. (2024). Internal rotation limitation is prevalent following modern reverse shoulder arthroplasty and negatively affects patients' subjective rating of the procedure. Journal of Shoulder and Elbow Surgery, 33(12), 2646–2654. https://doi.org/10.1016/j.jse.2024.03.011
- Skrede, A., Dalen, A. F., Hellevik, A. I., Stavdahl, Ø., & Bye, R. T. (2024). Quantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework. IEEE Access, 12, 29397–29413. https://doi.org/10.1109/access.2024.3368390
- Hochberger, F., Siebler, J., Rupp, M.-C., Scheiderer, B., Siebenlist, S., & Geyer, S. (2024). Demographic-, Radiographic-, and Surgery-Related Factors Do Not Affect Functional Internal Rotation Following Reverse Total Shoulder Arthroplasty: A Retrospective Comparative Study. Healthcare, 12(17), 1695. https://doi.org/10.3390/healthcare12171695
- Sanchez-Urgelles, P., Kolakowski, L., Levin, J. M., & Frankle, M. A. (2024). Development, Evolution, and Outcomes of More Anatomical Reverse Shoulder Arthroplasty. Journal of Clinical Medicine, 13(21), 6513. https://doi.org/10.3390/jcm13216513
- Chelli, M., Walch, G., Azar, M., Neyton, L., Lévigne, C., Favard, L., & Boileau, P. (2023). Glenoid lateralization and subscapularis repair are independent predictive factors of improved internal rotation after reverse shoulder arthroplasty. International Orthopaedics, 48(1), 127–132. https://doi.org/10.1007/s00264-023-06048-6
- Hao, K. A., Kakalecik, J., Cueto, R. J., Janke, R. L., Wright, J. O., Wright, T. W., Farmer, K. W., Struk, A. M., Schoch, B. S., & King, J. J. (2023). Discordance between patient-reported and objectively measured internal rotation after reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 32(10), 2051–2058. https://doi.org/10.1016/j.jse.2023.03.033
- King, J. J., Hones, K. M., Wright, T. W., Roche, C., Zuckerman, J. D., Flurin, P. H., & Schoch, B. S. (2023). Does isolated glenosphere lateralization affect outcomes in reverse shoulder arthroplasty?. Orthopaedics & Traumatology: Surgery & Research, 109(4), Article 103401. https://doi.org/10.1016/j.otsr.2022.103401
- Candela, V., Preziosi Standoli, J., Scacchi, M., & Gumina, S. (2023). The impact of coracoid morphometry on internal rotation outcome in patients with cuff tear arthropathy treated with reverse shoulder arthroplasty. Seminars in Arthroplasty: JSES, 33(3), 584–590. https://doi.org/10.1053/j.sart.2023.05.003
- Xu, X., Sun, Q., Liu, Y., Wang, D., Diao, S., Wang, H., Gao, Y., Lu, T., & Zhou, J. (2023). Comparative Analysis of Eccentric Glenosphere in Reverse Total Shoulder Arthroplasty: A Computer Simulation Study. International Journal of General Medicine, Volume 16, 4691–4704. https://doi.org/10.2147/ijgm.s426191
- Holschen, M., Körting, M., Khourdaji, P., Bockmann, B., Schulte, T. L., Witt, K.-A., & Steinbeck, J. (2022). Treatment of proximal humerus fractures using reverse shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical outcome and tuberosity healing?. Archives of Orthopaedic and Trauma Surgery, 142(12), 3817–3826. https://doi.org/10.1007/s00402-021-04281-5
- Collin, P., Rol, M., Muniandy, M., Gain, S., Lädermann, A., & Ode, G. (2022). Relationship between postoperative integrity of subscapularis tendon and functional outcome in reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 31(1), 63–71. https://doi.org/10.1016/j.jse.2021.05.024
- Hochreiter, B., Wyss, S., & Gerber, C. (2022). Extension of the shoulder is essential for functional internal rotation after reverse total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 31(6), 1166–1174. https://doi.org/10.1016/j.jse.2021.11.006
- Rohman, E., King, J. J., Roche, C. P., Fan, W., Kilian, C. M., & Papandrea, R. F. (2022). Factors associated with improvement or loss of internal rotation after reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 31(7), e346–e358. https://doi.org/10.1016/j.jse.2022.01.124
- Lauria, M., Hastings, M., DiPaola, M. J., Duquin, T. R., & Ablove, R. H. (2022). Factors affecting internal rotation following total shoulder arthroplasty. JSES Reviews, Reports, and Techniques, 2(4), 431–436. https://doi.org/10.1016/j.xrrt.2022.08.003
- Nayak, A. N., Gabriel, S. M., Spenciner, D. B., Mason, C. E., & Jacofsky, M. C. (2022). Development and Multisite Assessment of a Novel Shoulder Motion Joint Simulator. Journal of Biomechanical Engineering, 144(7). https://doi.org/10.1115/1.4053362
- Holschen, M., Kiriazis, A., Bockmann, B., Schulte, T. L., Witt, K.-A., & Steinbeck, J. (2021). Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome?. European Journal of Orthopaedic Surgery & Traumatology, 32(2), 307–315. https://doi.org/10.1007/s00590-021-02976-4
- Werner, B. C., Lederman, E., Gobezie, R., & Denard, P. J. (2021). Glenoid lateralization influences active internal rotation after reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 30(11), 2498–2505. https://doi.org/10.1016/j.jse.2021.02.021
- Hochreiter, B., Hasler, A., Hasler, J., Kriechling, P., Borbas, P., & Gerber, C. (2021). Factors influencing functional internal rotation after reverse total shoulder arthroplasty. JSES International, 5(4), 679–687. https://doi.org/10.1016/j.jseint.2021.03.005
- Budge, M., Lewis, G., & Vanname, J. (2021). The effect of glenoid version on internal and external rotation in reverse total shoulder arthroplasty. Seminars in Arthroplasty: JSES, 31(3), 502–509. https://doi.org/10.1053/j.sart.2021.02.005
- Lädermann, A., Denard, P. J., Collin, P., Zbinden, O., Chiu, J. C.-H., Boileau, P., Olivier, F., & Walch, G. (2020). Effect of humeral stem and glenosphere designs on range of motion and muscle length in reverse shoulder arthroplasty. International Orthopaedics, 44(3), 519–530. https://doi.org/10.1007/s00264-019-04463-2
1–25 of 33