Published October 20, 2022 | Journal article | Version v1 | https://doi.org/10.3389/ti.2022.10712

Interleukin-18 and High-Mobility-Group-Protein B1 are Early and Sensitive Indicators for Cell Damage During Normothermic Machine Perfusion after Prolonged Cold Ischemic Storage of Porcine Liver Grafts

Description

In the era of organ machine perfusion, experimental models to optimize reconditioning of (marginal) liver grafts are needed. Although the relevance of cytokine signatures in liver transplantation has been analyzed previously, the significance of molecular monitoring during normothermic machine perfusion (NMP) remains elusive. Therefore, we developed a porcine model of cold ischemic liver graft injury after prolonged static cold storage (SCS) and subsequent NMP: Livers obtained from ten minipigs underwent NMP for 6 h directly after procurement (control group) or after 20 h of SCS. Grafts after prolonged SCS showed significantly elevated AST, ALT, GLDH and GGT perfusate concentrations, and reduced lactate clearance. Bile analyses revealed reduced bile production, reduced bicarbonate and elevated glucose concentrations after prolonged SCS. Cytokine analyses of graft perfusate simultaneously demonstrated an increase of pro-inflammatory cytokines such as Interleukin-1α, Interleukin-2, and particularly Interleukin-18. The latter was the only significantly elevated cytokine compared to controls, peaking as early as 2 h after reperfusion (11,012 ng/ml vs. 1,493 ng/ml; p = 0.029). Also, concentrations of High-Mobility-Group-Protein B1 were significantly elevated after 2 h of reperfusion (706.00 ng/ml vs. 148.20 ng/ml; p < 0.001) and showed positive correlations with AST (r2 = 0.846) and GLDH (r2 = 0.918) levels. Molecular analyses during reconditioning of liver grafts provide insights into the degree of inflammation and cell damage and could thereby facilitate future interventions during NMP reducing acute and chronic graft injury.

Additional details

Dates

Issued
October 20, 2022

References

  1. Resch, T., Cardini, B., Oberhuber, R., Weissenbacher, A., Dumfarth, J., Krapf, C., Boesmueller, C., Oefner, D., Grimm, M., & Schneeberger, S. (2020). Transplanting Marginal Organs in the Era of Modern Machine Perfusion and Advanced Organ Monitoring. Frontiers in Immunology, 11. https://doi.org/10.3389/fimmu.2020.00631
  2. Vodkin, I., & Kuo, A. (2017). Extended Criteria Donors in Liver Transplantation. Clinics in Liver Disease, 21(2), 289–301. https://doi.org/10.1016/j.cld.2016.12.004
  3. Muhammad, H., Zaffar, D., Tehreem, A., Ting, P.-S., Simsek, C., Turan, I., Alqahtani, S., Saberi, B., & Gurakar, A. (2021). An Update on Usage of High-Risk Donors in Liver Transplantation. Journal of Clinical Medicine, 11(1), 215. https://doi.org/10.3390/jcm11010215
  4. Oldhafer, F., Beetz, O., Cammann, S., Richter, N., Klempnauer, J., & Vondran, F. W. R. (2021). Maschinenperfusion in der Lebertransplantation – was ist möglich und wo stehen wir in Deutschland? Übersicht der Literatur und Ergebnisse einer nationalen Umfrage. Zentralblatt für Chirurgie - Zeitschrift für Allgemeine, Viszeral-, Thorax- und Gefäßchirurgie, 146(04), 382–391. https://doi.org/10.1055/a-1363-2520
  5. Bonaccorsi-Riani, E., Brüggenwirth, I. M. A., Buchwald, J. E., Iesari, S., & Martins, P. N. (2020). Machine Perfusion: Cold versus Warm, versus Neither. Update on Clinical Trials. Seminars in Liver Disease, 40(03), 264–281. https://doi.org/10.1055/s-0040-1713118
  6. Liu, Q., Nassar, A., Farias, K., Buccini, L., Mangino, M. J., Baldwin, W., Bennett, A., O'Rourke, C., Iuppa, G., Soliman, B. G., Urcuyo-Llanes, D., Okamoto, T., Uso, T. D., Fung, J., Abu-Elmagd, K., Miller, C., & Quintini, C. (2016). Comparing Normothermic Machine Perfusion Preservation With Different Perfusates on Porcine Livers From Donors After Circulatory Death. American Journal of Transplantation, 16(3), 794–807. https://doi.org/10.1111/ajt.13546
  7. Laing, R. W., Mergental, H., Yap, C., Kirkham, A., Whilku, M., Barton, D., Curbishley, S., Boteon, Y. L., Neil, D. A., Hübscher, S. G., Perera, M. T. P. R., Muiesan, P., Isaac, J., Roberts, K. J., Cilliers, H., Afford, S. C., & Mirza, D. F. (2017). Viability testing and transplantation of marginal livers (VITTAL) using normothermic machine perfusion: study protocol for an open-label, non-randomised, prospective, single-arm trial. BMJ Open, 7(11), e017733. https://doi.org/10.1136/bmjopen-2017-017733
  8. Sosa, R. A., Zarrinpar, A., Rossetti, M., Lassman, C. R., Naini, B. V., Datta, N., Rao, P., Harre, N., Zheng, Y., Spreafico, R., Hoffmann, A., Busuttil, R. W., Gjertson, D. W., Zhai, Y., Kupiec-Weglinski, J. W., & Reed, E. F. (2016). Early cytokine signatures of ischemia/reperfusion injury in human orthotopic liver transplantation. JCI Insight, 1(20). https://doi.org/10.1172/jci.insight.89679
  9. Nagakawa, K., Soyama, A., Hidaka, M., Adachi, T., Ono, S., Hara, T., Takatsuki, M., & Eguchi, S. (2020). Elevated Plasma Levels of Mitochondria-Derived Damage-Associated Molecular Patterns during Liver Transplantation: Predictors for Postoperative Multi-Organ Dysfunction Syndrome. The Tohoku Journal of Experimental Medicine, 250(2), 87–93. https://doi.org/10.1620/tjem.250.87
  10. Ferdinand, J. R., Hosgood, S. A., Moore, T., Ferro, A., Ward, C. J., Castro-Dopico, T., Nicholson, M. L., & Clatworthy, M. R. (2021). Cytokine absorption during human kidney perfusion reduces delayed graft function–associated inflammatory gene signature. American Journal of Transplantation, 21(6), 2188–2199. https://doi.org/10.1111/ajt.16371
  11. Oldhafer, F., Wittauer, E.-M., Beetz, O., & Vondran, F. W. R. (2020). Long-term Functional Maintenance of Exteriorized Portal Venous Catheters in a Porcine Animal Model. Journal of Surgical Research, 251, 187–194. https://doi.org/10.1016/j.jss.2020.02.003
  12. Oldhafer, F., Wittauer, E.-M., Beetz, O., Weigle, C. A., Sieg, L., Eismann, H., Braubach, P., Bock, M., Jonigk, D., Johanning, K., & Vondran, F. W. R. (2021). Supportive Hepatocyte Transplantation after Partial Hepatectomy Enhances Liver Regeneration in a Preclinical Pig Model. European Surgical Research, 62(4), 238–247. https://doi.org/10.1159/000516690
  13. Chui, A. K. K., Thompson, J. F., Lam, D., Koutalistras, N., Wang, L., Verran, D. J., & Sheil, A. G. R. (1998). CADAVERIC LIVER PROCUREMENT USING AORTIC PERFUSION ONLY. Australian and New Zealand Journal of Surgery, 68(4), 275–277. https://doi.org/10.1111/j.1445-2197.1998.tb02081.x
  14. Ali, J. M., Davies, S. E., Brais, R. J., Randle, L. V., Klinck, J. R., Allison, M. E. D., Chen, Y., Pasea, L., Harper, S. F. J., & Pettigrew, G. J. (2015). Analysis of ischemia/reperfusion injury in time‐zero biopsies predicts liver allograft outcomes. Liver Transplantation, 21(4), 487–499. https://doi.org/10.1002/lt.24072
  15. Hansen, T., Hollemann, D., Pitton, M. B., Heise, M., Hoppe-Lotichius, M., Schuchmann, M., Kirkpatrick, C. J., & Otto, G. (2012). Histological examination and evaluation of donor bile ducts received during orthotopic liver transplantation—a morphological clue to ischemic-type biliary lesion?. Virchows Archiv, 461(1), 41–48. https://doi.org/10.1007/s00428-012-1245-8
  16. op den Dries, S., Westerkamp, A. C., Karimian, N., Gouw, A. S. H., Bruinsma, B. G., Markmann, J. F., Lisman, T., Yeh, H., Uygun, K., Martins, P. N., & Porte, R. J. (2014). Injury to peribiliary glands and vascular plexus before liver transplantation predicts formation of non-anastomotic biliary strictures. Journal of Hepatology, 60(6), 1172–1179. https://doi.org/10.1016/j.jhep.2014.02.010
  17. Renne, J., Gutberlet, M., Voskrebenzev, A., Kern, A., Kaireit, T., Hinrichs, J. B., Braubach, P., Falk, C. S., Höffler, K., Warnecke, G., Zardo, P., Haverich, A., Wacker, F., Vogel-Claussen, J., & Zinne, N. (2019). Functional Pulmonary Magnetic Resonance Imaging for Detection of Ischemic Injury in a Porcine Ex-Vivo Lung Perfusion System Prior to Transplantation. Academic Radiology, 26(2), 170–178. https://doi.org/10.1016/j.acra.2018.05.006
  18. Dar, W. A., Sullivan, E., Bynon, J. S., Eltzschig, H., & Ju, C. (2019). Ischaemia reperfusion injury in liver transplantation: Cellular and molecular mechanisms. Liver International, 39(5), 788–801. https://doi.org/10.1111/liv.14091
  19. Oliveira, T. H. C. de ., Marques, P. E., Proost, P., & Teixeira, M. M. M. (2018). Neutrophils: a cornerstone of liver ischemia and reperfusion injury. Laboratory Investigation, 98(1), 51–62. https://doi.org/10.1038/labinvest.2017.90
  20. Czigany, Z., Lurje, I., Schmelzle, M., Schöning, W., Öllinger, R., Raschzok, N., Sauer, I. M., Tacke, F., Strnad, P., Trautwein, C., Neumann, U. P., Fronek, J., Mehrabi, A., Pratschke, J., Schlegel, A., & Lurje, G. (2020). Ischemia-Reperfusion Injury in Marginal Liver Grafts and the Role of Hypothermic Machine Perfusion: Molecular Mechanisms and Clinical Implications. Journal of Clinical Medicine, 9(3), 846. https://doi.org/10.3390/jcm9030846
  21. Clarke, G., Mergental, H., Hann, A., Perera, M. T. P. R., Afford, S. C., & Mirza, D. F. (2021). How Machine Perfusion Ameliorates Hepatic Ischaemia Reperfusion Injury. International Journal of Molecular Sciences, 22(14), 7523. https://doi.org/10.3390/ijms22147523
  22. Markmann, J. F., Abouljoud, M. S., Ghobrial, R. M., Bhati, C. S., Pelletier, S. J., Lu, A. D., Ottmann, S., Klair, T., Eymard, C., Roll, G. R., Magliocca, J., Pruett, T. L., Reyes, J., Black, S. M., Marsh, C. L., Schnickel, G., Kinkhabwala, M., Florman, S. S., Merani, S., … MacConmara, M. P. (2022). Impact of Portable Normothermic Blood-Based Machine Perfusion on Outcomes of Liver Transplant. JAMA Surgery, 157(3), 189. https://doi.org/10.1001/jamasurg.2021.6781
  23. Jassem, W., Xystrakis, E., Ghnewa, Y. G., Yuksel, M., Pop, O., Martinez‐Llordella, M., Jabri, Y., Huang, X., Lozano, J. J., Quaglia, A., Sanchez‐Fueyo, A., Coussios, C. C., Rela, M., Friend, P., Heaton, N., & Ma, Y. (2019). Normothermic Machine Perfusion (NMP) Inhibits Proinflammatory Responses in the Liver and Promotes Regeneration. Hepatology, 70(2), 682–695. https://doi.org/10.1002/hep.30475
  24. Europe, . for . the C. for O. P. in ., Nasralla, D., Coussios, C. C., Mergental, H., Akhtar, M. Z., Butler, A. J., Ceresa, C. D. L., Chiocchia, V., Dutton, S. J., García-Valdecasas, J. C., Heaton, N., Imber, C., Jassem, W., Jochmans, I., Karani, J., Knight, S. R., Kocabayoglu, P., Malagò, M., Mirza, D., … Friend, P. J. (2018). A randomized trial of normothermic preservation in liver transplantation. Nature, 557(7703), 50–56. https://doi.org/10.1038/s41586-018-0047-9
  25. Mergental, H., Laing, R. W., Kirkham, A. J., Perera, M. T. P. R., Boteon, Y. L., Attard, J., Barton, D., Curbishley, S., Wilkhu, M., Neil, D. A. H., Hübscher, S. G., Muiesan, P., Isaac, J. R., Roberts, K. J., Abradelo, M., Schlegel, A., Ferguson, J., Cilliers, H., Bion, J., … Mirza, D. F. (2020). Transplantation of discarded livers following viability testing with normothermic machine perfusion. Nature Communications, 11(1). https://doi.org/10.1038/s41467-020-16251-3
  26. Takeuchi, D., Yoshidome, H., Kato, A., Ito, H., Kimura, F., Shimizu, H., Ohtsuka, M., Morita, Y., & Miyazaki, M. (2004). Interleukin 18 causes hepatic ischemia/reperfusion injury by suppressing anti-inflammatory cytokine expression in mice. Hepatology, 39(3), 699–710. https://doi.org/10.1002/hep.20117
  27. Bal, A., Gonul, Y., Hazman, O., Kocak, A., Bozkurt, M. F., Yilmaz, S., Kokulu, S., Oruc, O., & Demir, K. (2016). Interleukin 18–binding protein ameliorates liver ischemia–reperfusion injury. Journal of Surgical Research, 201(1), 13–21. https://doi.org/10.1016/j.jss.2015.10.008
  28. Ilmakunnas, M., Tukiainen, E. M., Rouhiainen, A., Rauvala, H., Arola, J., Nordin, A., Mäkisalo, H., Höckerstedt, K., & Isoniemi, H. (2008). High Mobility Group Box 1 Protein as a Marker of Hepatocellular Injury in Human Liver Transplantation. Liver Transplantation, 14(10), 1517–1525. https://doi.org/10.1002/lt.21573
  29. Tsung, A., Sahai, R., Tanaka, H., Nakao, A., Fink, M. P., Lotze, M. T., Yang, H., Li, J., Tracey, K. J., Geller, D. A., & Billiar, T. R. (2005). The nuclear factor HMGB1 mediates hepatic injury after murine liver ischemia-reperfusion. The Journal of Experimental Medicine, 201(7), 1135–1143. https://doi.org/10.1084/jem.20042614
  30. Watanabe, T., Kubota, S., Nagaya, M., Ozaki, S., Nagafuchi, H., Akashi, K., Taira, Y., Tsukikawa, S., Oowada, S., & Nakano, S. (2005). The role of HMGB-1 on the development of necrosis during hepatic ischemia and hepatic ischemia/reperfusion injury in mice. Journal of Surgical Research, 124(1), 59–66. https://doi.org/10.1016/j.jss.2004.10.019
  31. Scheuermann, U., Zhu, M., Song, M., Yerxa, J., Gao, Q., Davis, R. P., Zhang, M., Parker, W., Hartwig, M. G., Kwun, J., Brennan, T. V., Lee, J., & Barbas, A. S. (2019). Damage‐Associated Molecular Patterns Induce Inflammatory Injury During Machine Preservation of the Liver: Potential Targets to Enhance a Promising Technology. Liver Transplantation, 25(4), 610–626. https://doi.org/10.1002/lt.25429
  32. Goldaracena, N., Echeverri, J., Spetzler, V. N., Kaths, J. M., Barbas, A. S., Louis, K. S., Adeyi, O. A., Grant, D. R., Selzner, N., & Selzner, M. (2016). Anti‐inflammatory signaling during ex vivo liver perfusion improves the preservation of pig liver grafts before transplantation. Liver Transplantation, 22(11), 1573–1583. https://doi.org/10.1002/lt.24603
  33. Obara, H., Morito, N., Matsuno, N., Yoshikawa, R., Nakajo, T., Gochi, M., Otani, M., Shonaka, T., Furukawa, H., Hirano, T., & Enosawa, S. (2019). Initial perfusate purification during subnormothermic machine perfusion for porcine liver donated after cardiac death. Journal of Artificial Organs, 23(1), 62–69. https://doi.org/10.1007/s10047-019-01123-5
  34. Hosgood, S. A., Moore, T., Kleverlaan, T., Adams, T., & Nicholson, M. L. (2017). Haemoadsorption reduces the inflammatory response and improves blood flow during ex vivo renal perfusion in an experimental model. Journal of Translational Medicine, 15(1). https://doi.org/10.1186/s12967-017-1314-5
  35. Iskender, I., Cosgun, T., Arni, S., Trinkwitz, M., Fehlings, S., Cesarovic, N., Frauenfelder, T., Weder, W., & Inci, I. (2016). Cytokine Filtration Modulates Pulmonary Metabolism and Edema Formation During Ex Vivo Lung Perfusion. The Journal of Heart and Lung Transplantation, 35(4), S142–S143. https://doi.org/10.1016/j.healun.2016.01.393
  36. Garcia-Aroz, S., Xu, M., Ahmed, O., Hollingshead, J., Wang, X., Banan, B., Khan, A., Kang, L.-I., Zhang, Z., Upadhya, G., Manning, P., Lin, Y., & Chapman, W. C. (2021). Improving Liver Graft Function Using CD47 Blockade in the Setting of Normothermic Machine Perfusion. Transplantation, 106(1), 37–47. https://doi.org/10.1097/tp.0000000000003688

Citations

  1. An, P., An, Y., Chen, M., Wu, L., & Wang, R. (2026). Damage-associated molecular patterns in hepatic ischemia–reperfusion injury: spatiotemporal signatures, biomarker potential, and clinical translation. Frontiers in Immunology, 17. https://doi.org/10.3389/fimmu.2026.1789287
  2. Wehrle, C. J., Panconesi, R., & Schlegel, A. (2025). Machine Perfusion in Liver Transplantation. In Liver Transplantation (pp. 241–251). Springer Nature Switzerland. https://doi.org/10.1007/978-3-032-07072-2_16
  3. Tanaka, K., Uchida, Y., Kadono, K., Kageyama, S., Kawamoto, H., Ito, M., Kidoguchi, Y., Saga, K., Kojima, H., Hirao, H., Nakamura, K., Taura, K., Terajima, H., Watanabe, T., & Hatano, E. (2025). Recipient toll-like receptor 4 determines the outcome of ischemia-reperfusion injury in steatotic liver transplantation in mice. American Journal of Transplantation, 25(6), 1168–1179. https://doi.org/10.1016/j.ajt.2025.03.005
  4. Pezzati, D., Torri, F., Franzini, M., Balzano, E., Catalano, G., Tincani, G., Bronzoni, J., Martinelli, C., Trizzino, A., Petagna, L., Carrai, P., Petruccelli, S., Masini, M., Rotondo, M. I., Babboni, S., Del Turco, S., Morganti, R., De Tata, V., Biancofiore, G., … Ghinolfi, D. (2025). Association of perfusate cytokine concentrations during liver graft ex situ normothermic perfusion to donor type and postoperative outcomes. Liver Transplantation, 31(7), 877–889. https://doi.org/10.1097/lvt.0000000000000583
  5. Cammann, S., Beetz, O., Weigle, C. A., Tessmer, P., Wiemann, B., DeTemple, D. E., Neubert, L., Ramackers, W., Vondran, F. W. R., & Oldhafer, F. (2025). Noninvasive 13C-methacetin Liver Function Breath Test as a Tool for Functional Assessment During Normothermic Machine Perfusion of Porcine Livers. Transplantation Direct, 11(12), e1876. https://doi.org/10.1097/txd.0000000000001876
  6. Caballero-Marcos, A., Rodríguez-Bachiller, L., Baroja-Mazo, A., Morales, Á., Fernández-Cáceres, P., Fernández-Martínez, M., DíazFontenla, F., Velasco, E., Fernández-Yunquera, A., Díaz-Zorita, B., Cortese, S., Pérez-Peña, J. M., Colón-Rodríguez, A., Romero-Cristóbal, M., Asencio, J. M., Bañares, R., López-Baena, J. Á., & Salcedo-Plaza, M. (2024). Dynamics of Ischemia/Reperfusion Injury Markers During Normothermic Liver Machine Perfusion. Transplantation Direct, 10(12), e1728. https://doi.org/10.1097/txd.0000000000001728
  7. Schlegel, A., Mergental, H., Fondevila, C., Porte, R. J., Friend, P. J., & Dutkowski, P. (2023). Machine perfusion of the liver and bioengineering. Journal of Hepatology, 78(6), 1181–1198. https://doi.org/10.1016/j.jhep.2023.02.009
  8. Cao, Y., Zhi, J., Ren, H., Sheng, M., Jia, L., Weng, Y., Du, H., & Yu, W. (2023). Association between serum HMGB1 elevation and early pediatric acute respiratory distress syndrome: a retrospective study of pediatric living donor liver transplant recipients with biliary atresia in China. BMC Anesthesiology, 23(1). https://doi.org/10.1186/s12871-023-02040-0
  9. Radomsky, L., Koch, A., Olbertz, C., Liu, Y., Beushausen, K., Keil, J., Rauen, U., Falk, C. S., Kühne, J. F., & Kamler, M. (2023). Composition of ex vivo perfusion solutions and kinetics define differential cytokine/chemokine secretion in a porcine cardiac arrest model of lung preservation. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1245618