Published April 9, 2024 | Journal article | Version v1 | https://doi.org/10.1007/s00590-024-03898-7

Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study

Description

Abstract Purpose The anterior stability of reverse total shoulder arthroplasty is affected by multiple factors. However, the effect of glenosphere inclination on stability has rarely been investigated, which is what this study aims to look into. Methods Reverse shoulder arthroplasty was performed on 15 cadaveric human shoulders. The anterior dislocation forces and range of motion in internal rotation in the glenohumeral joint (primary measured parameters) were tested in a shoulder simulator in different arm positions and implant configurations, as well as with a custom-made 10° inferiorly inclined glenosphere. The inclination and retroversion of the baseplate as well as the distance between the glenoid and coracoid tip in two planes (secondary measured parameters) were evaluated on CT scans. Results In biomechanical testing, the custom-made inclined glenosphere showed no significant influence on anterior stability other than glenoid lateralisation over all arm positions as well as the neck-shaft angle in two arm positions. The 6 mm lateralised glenosphere reduced internal rotation at 30° and 60° of glenohumeral abduction. In 30° of glenohumeral abduction, joint stability was increased using the 155° epiphysis compared with the 145° epiphysis. The mean inclination was 16.1°. The inclination was positively, and the distance between the glenoid and coracoid tip in the anterior-to-posterior direction was negatively correlated with anterior dislocation forces. Conclusions The custom-made inferiorly inclined glenosphere did not influence anterior stability, but baseplate inclination itself had a significant effect on stability.

Additional details

Funding

DePuy Synthes
Medizinische Hochschule Hannover (MHH)

Dates

Issued
April 9, 2024

References

  1. Grammont, P. M., & Baulot, E. (1993). DELTA SHOULDER PROSTHESIS FOR ROTATOR CUFF RUPTURE. Orthopedics, 16(1), 65–68. https://doi.org/10.3928/0147-7447-19930101-11
  2. Kennedy, J., Klifto, C. S., Ledbetter, L., & Bullock, G. S. (2021). Reverse total shoulder arthroplasty clinical and patient-reported outcomes and complications stratified by preoperative diagnosis: a systematic review. Journal of Shoulder and Elbow Surgery, 30(4), 929–941. https://doi.org/10.1016/j.jse.2020.09.028
  3. Chalmers, P. N., Salazar, D. H., Romeo, A. A., Keener, J. D., Yamaguchi, K., & Chamberlain, A. M. (2018). Comparative Utilization of Reverse and Anatomic Total Shoulder Arthroplasty: A Comprehensive Analysis of a High-volume Center. Journal of the American Academy of Orthopaedic Surgeons, 26(24), e504–e510. https://doi.org/10.5435/jaaos-d-17-00075
  4. Gallo, R. A., Gamradt, S. C., Mattern, C. J., Cordasco, F. A., Craig, E. V., Dines, D. M., & Warren, R. F. (2011). Instability after reverse total shoulder replacement. Journal of Shoulder and Elbow Surgery, 20(4), 584–590. https://doi.org/10.1016/j.jse.2010.08.028
  5. Kohan, E. M., Chalmers, P. N., Salazar, D., Keener, J. D., Yamaguchi, K., & Chamberlain, A. M. (2017). Dislocation following reverse total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 26(7), 1238–1245. https://doi.org/10.1016/j.jse.2016.12.073
  6. Ravi, V., Murphy, R. J., Moverley, R., Derias, M., & Phadnis, J. (2021). Outcome and complications following revision shoulder arthroplasty. Bone & Joint Open, 2(8), 618–630. https://doi.org/10.1302/2633-1462.28.bjo-2021-0092.r1
  7. Zumstein, M. A., Pinedo, M., Old, J., & Boileau, P. (2011). Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: A systematic review. Journal of Shoulder and Elbow Surgery, 20(1), 146–157. https://doi.org/10.1016/j.jse.2010.08.001
  8. Berliner, J. L., Regalado-Magdos, A., Ma, C. B., & Feeley, B. T. (2015). Biomechanics of reverse total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 24(1), 150–160. https://doi.org/10.1016/j.jse.2014.08.003
  9. Clouthier, A. L., Hetzler, M. A., Fedorak, G., Bryant, J. T., Deluzio, K. J., & Bicknell, R. T. (2013). Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study. Journal of Shoulder and Elbow Surgery, 22(4), 439–444. https://doi.org/10.1016/j.jse.2012.05.032
  10. Favre, P., Sussmann, P. S., & Gerber, C. (2010). The effect of component positioning on intrinsic stability of the reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 19(4), 550–556. https://doi.org/10.1016/j.jse.2009.11.044
  11. Gutiérrez, S., Keller, T. S., Levy, J. C., Lee, W. E., & Luo, Z.-P. (2008). Hierarchy of Stability Factors in Reverse Shoulder Arthroplasty. Clinical Orthopaedics & Related Research, 466(3), 670–676. https://doi.org/10.1007/s11999-007-0096-0
  12. Pastor, M.-F., Kraemer, M., Wellmann, M., Hurschler, C., & Smith, T. (2016). Anterior stability of the reverse shoulder arthroplasty depending on implant configuration and rotator cuff condition. Archives of Orthopaedic and Trauma Surgery, 136(11), 1513–1519. https://doi.org/10.1007/s00402-016-2560-3
  13. Randelli, P., Randelli, F., Arrigoni, P., Ragone, V., D’Ambrosi, R., Masuzzo, P., Cabitza, P., & Banfi, G. (2014). Optimal glenoid component inclination in reverse shoulder arthroplasty. How to improve implant stability. MUSCULOSKELETAL SURGERY, 98(S1), 15–18. https://doi.org/10.1007/s12306-014-0324-1
  14. Tashjian, R. Z., Martin, B. I., Ricketts, C. A., Henninger, H. B., Granger, E. K., & Chalmers, P. N. (2018). Superior Baseplate Inclination Is Associated With Instability After Reverse Total Shoulder Arthroplasty. Clinical Orthopaedics & Related Research, 476(8), 1622–1629. https://doi.org/10.1097/corr.0000000000000340
  15. Bechtold, D. A., Ganapathy, P. K., Aleem, A. W., Chamberlain, A. M., & Keener, J. D. (2021). The relationship between glenoid inclination and instability following primary reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 30(7), e370–e377. https://doi.org/10.1016/j.jse.2020.09.037
  16. Gutiérrez, S., Walker, M., Willis, M., Pupello, D. R., & Frankle, M. A. (2011). Effects of tilt and glenosphere eccentricity on baseplate/bone interface forces in a computational model, validated by a mechanical model, of reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 20(5), 732–739. https://doi.org/10.1016/j.jse.2010.10.035
  17. Patel, M., Martin, J. R., Campbell, D. H., Fernandes, R. R., & Amini, M. H. (2021). Inferior tilt of the glenoid leads to medialization and increases impingement on the scapular neck in reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 30(6), 1273–1281. https://doi.org/10.1016/j.jse.2020.09.023
  18. Mollon, B., Mahure, S. A., Roche, C. P., & Zuckerman, J. D. (2017). Impact of scapular notching on clinical outcomes after reverse total shoulder arthroplasty: an analysis of 476 shoulders. Journal of Shoulder and Elbow Surgery, 26(7), 1253–1261. https://doi.org/10.1016/j.jse.2016.11.043
  19. Simovitch, R., Flurin, P.-H., Wright, T. W., Zuckerman, J. D., & Roche, C. (2019). Impact of scapular notching on reverse total shoulder arthroplasty midterm outcomes: 5-year minimum follow-up. Journal of Shoulder and Elbow Surgery, 28(12), 2301–2307. https://doi.org/10.1016/j.jse.2019.04.042
  20. Helmkamp, J. K., Bullock, G. S., Amilo, N. R., Guerrero, E. M., Ledbetter, L. S., Sell, T. C., & Garrigues, G. E. (2018). The clinical and radiographic impact of center of rotation lateralization in reverse shoulder arthroplasty: a systematic review. Journal of Shoulder and Elbow Surgery, 27(11), 2099–2107. https://doi.org/10.1016/j.jse.2018.07.007
  21. Faul, F., Erdfelder, E., Buchner, A., & Lang, A.-G. (2009). Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses. Behavior Research Methods, 41(4), 1149–1160. https://doi.org/10.3758/brm.41.4.1149
  22. Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007). G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behavior Research Methods, 39(2), 175–191. https://doi.org/10.3758/bf03193146
  23. Ferle, M., Pastor, M.-F., Hagenah, J., Hurschler, C., & Smith, T. (2019). Effect of the humeral neck-shaft angle and glenosphere lateralization on stability of reverse shoulder arthroplasty: a cadaveric study. Journal of Shoulder and Elbow Surgery, 28(5), 966–973. https://doi.org/10.1016/j.jse.2018.10.025
  24. Krämer, M., Bäunker, A., Wellmann, M., Hurschler, C., & Smith, T. (2016). Implant impingement during internal rotation after reverse shoulder arthroplasty. The effect of implant configuration and scapula anatomy: A biomechanical study. Clinical Biomechanics, 33, 111–116. https://doi.org/10.1016/j.clinbiomech.2016.02.015
  25. Pastor, M.-F., Ferle, M., Hagenah, J., Ellwein, A., Wellmann, M., & Smith, T. (2019). The stabilization effect of the conjoint tendon in reverse total shoulder arthroplasty. Clinical Biomechanics, 63, 179–184. https://doi.org/10.1016/j.clinbiomech.2019.03.009

1–25 of 39