Published January 12, 2026 | Journal article | Version v1 | https://doi.org/10.1002/acn3.70307

Effects of Biological Sex and Age on Cerebrospinal Fluid Markers—A Retrospective Observational Study

Description

ABSTRACT Objective Cerebrospinal fluid (CSF) analysis is a key diagnostic tool for neurological diseases. To date, only a few studies have investigated in larger cohorts the effect of age and biological sex on diagnostic markers extracted from CSF. Methods For this retrospective observational study, 4163 CSF findings (2012–2020) were evaluated. After exclusion of pathogenic CSF findings above or below the locally established reference ranges that are routinely applied in the CSF laboratory for clinical reporting, 1270 findings were included for statistical analysis. Using regression analysis, the relationship between age and CSF markers was illustrated, and regression equations were created. Results A significant effect of sex was shown for CSF albumin ( p  < 0.001; Δ M 29.34), CSF protein ( p  < 0.001; Δ M 39.38) and CSF glucose ( p  < 0.001; Δ M 3.63) as well as CSF/serum albumin quotient (Q Alb) ( p  < 0.001; Δ M 0.57), for Immunoglobulin G in CSF (IgG CSF) ( p  < 0.001; Δ M 2.48), CSF/serum IgG quotient (Q IgG) ( p  < 0.001; Δ M 0.27), Immunoglobulin A in CSF (IgA CSF) ( p  < 0.001; Δ M 0.52), CSF/serum IgA quotient (Q IgA) ( p  < 0.001; Δ M 0.15) and CSF/serum IgM quotient (Q IgM) ( p  < 0.001; Δ M 0.09). Age showed a significant effect throughout most CSF markers, most strongly for CSF protein ( p  < 0.001; η 2  = 0.16) and Q Alb ( p  < 0.001; η 2  = 0.23). Both parameters increased significantly with age, leading to higher mean values in older individuals. Interpretation For almost all markers in CSF, a significant effect of age alone on the markers or a significant effect of sex and age on the markers could be detected. Our study underscores the importance of age‐ and sex‐adjusted reference values for the interpretation of CSF markers in clinical practice.

Additional details

Dates

Issued
January 12, 2026

References

  1. Tumani, H., Petereit, H. F., Gerritzen, A., Groß, C. C., Huss, A., Isenmann, S., Jesse, S., Khalil, M., Lewerenz, J., Leypoldt, F., Melzer, N., Meuth, S. G., Otto, M., Ruprecht, K., Sindern, E., Spreer, A., Stangel, M., Strik, H., Uhr, M., … Zimmermann, T. (2019). S1-Leitlinie: Lumbalpunktion und Liquordiagnostik: Zusammenfassung der Leitlinie der Deutschen Gesellschaft für Neurologie. DGNeurologie, 2(6), 456–480. https://doi.org/10.1007/s42451-019-00126-z
  2. Leen, W. G., Willemsen, M. A., Wevers, R. A., Verbeek, M. M., & Mendelson, J. E. (2012). Cerebrospinal Fluid Glucose and Lactate: Age-Specific Reference Values and Implications for Clinical Practice. PLoS ONE, 7(8), e42745. https://doi.org/10.1371/journal.pone.0042745
  3. Reiber, H. (1998). Cerebrospinal fluid - physiology, analysis and interpretation of protein patterns for diagnosis of neurological diseases. Multiple Sclerosis Journal, 4(3), 99–107. https://doi.org/10.1177/135245859800400302
  4. Deisenhammer, F., Bartos, A., Egg, R., Gilhus, N. E., Giovannoni, G., Rauer, S., & Sellebjerg, F. (2006). Guidelines on routine cerebrospinal fluid analysis. Report from an EFNS task force. European Journal of Neurology, 13(9), 913–922. https://doi.org/10.1111/j.1468-1331.2006.01493.x
  5. Reiber, H. (2016). Knowledge-base for interpretation of cerebrospinal fluid data patterns. Essentials in neurology and psychiatry. Arquivos De Neuro-Psiquiatria, 74(6), 501–512. https://doi.org/10.1590/0004-282x20160066
  6. Jarius, S., Eichhorn, P., Franciotta, D., Petereit, H. F., Akman-Demir, G., Wick, M., & Wildemann, B. (2016). The MRZ reaction as a highly specific marker of multiple sclerosis: re-evaluation and structured review of the literature. Journal of Neurology, 264(3), 453–466. https://doi.org/10.1007/s00415-016-8360-4
  7. Teunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Frederiksen, J. L., Fleming, J. O., Furlan, R., Hintzen, MD, R. Q., Hughes, S. G., Johnson, M. H., Krasulova, E., Kuhle, J., Magnone, M. C., Rajda, C., Rejdak, K., Schmidt, H. K., … Deisenhammer, F. (2009). A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking. Neurology, 73(22), 1914–1922. https://doi.org/10.1212/wnl.0b013e3181c47cc2
  8. Ruprecht, K., & Tumani, H. (2016). Liquordiagnostik bei Multipler Sklerose. Der Nervenarzt, 87(12), 1282–1287. https://doi.org/10.1007/s00115-016-0220-z
  9. Moores, G., Steadman, P. E., Momen, A., Wolff, E., Pikula, A., & Bui, E. (2023). Sex differences in neurology: a scoping review. BMJ Open, 13(4), e071200. https://doi.org/10.1136/bmjopen-2022-071200
  10. Parrado‐Fernández, C., Blennow, K., Hansson, M., Leoni, V., Cedazo‐Minguez, A., & Björkhem, I. (2018). Evidence for sex difference in the CSF /plasma albumin ratio in ~20 000 patients and 335 healthy volunteers. Journal of Cellular and Molecular Medicine, 22(10), 5151–5154. https://doi.org/10.1111/jcmm.13767
  11. Garton, M. J., Keir, G., Lakshmi, M. V., & Thompson, E. J. (1991). Age-related changes in cerebrospinal fluid protein concentrations. Journal of the Neurological Sciences, 104(1), 74–80. https://doi.org/10.1016/0022-510x(91)90218-v
  12. Bourque, P. R., Brooks, J., McCudden, C. R., Warman-Chardon, J., & Breiner, A. (2019). Age matters. Neurology Neuroimmunology & Neuroinflammation, 6(4). https://doi.org/10.1212/nxi.0000000000000576
  13. Blennow, K., Fredman, P., Wallin, A., Gottfries, C.-G., Skoog, I., Wikkelsö, C., & Svennerholm, L. (1993). Protein Analysis in Cerebrospinal Fluid. European Neurology, 33(2), 134–142. https://doi.org/10.1159/000116920
  14. Reiber, H. (1994). Flow rate of cerebrospinal fluid (CSF) — A concept common to normal blood-CSF barrier function and to dysfunction in neurological diseases. Journal of the Neurological Sciences, 122(2), 189–203. https://doi.org/10.1016/0022-510x(94)90298-4
  15. Rinker, J. R., Trinkaus, K., Naismith, R. T., & Cross, A. H. (2007). Higher IgG index found in African Americans versus Caucasians with multiple sclerosis. Neurology, 69(1), 68–72. https://doi.org/10.1212/01.wnl.0000265057.79843.d9
  16. Tibbling, G., Link, H., & Öhman, S. (1977). Principles of albumin and IgG analyses in neurological disorders. I. Establishment of reference values. Scandinavian Journal of Clinical and Laboratory Investigation, 37(5), 385–390. https://doi.org/10.3109/00365517709091496
  17. Reiber, H., Ungefehr, S., & Jacobi, C. (1998). The intrathecal, polyspecific and oligoclonal immune response in multiple sclerosis. Multiple Sclerosis Journal, 4(3), 111–117. https://doi.org/10.1177/135245859800400304
  18. Felgenhauer, K., & Reiber, H. (1992). The diagnostic significance of antibody specificity indices in multiple sclerosis and herpes virus induced diseases of the nervous system. The Clinical Investigator, 70(1), 28–37. https://doi.org/10.1007/bf00422934
  19. Castellazzi, M., Morotti, A., Tamborino, C., Alessi, F., Pilotto, S., Baldi, E., Caniatti, L. M., Trentini, A., Casetta, I., Granieri, E., Pugliatti, M., Fainardi, E., & Bellini, T. (2020). Increased age and male sex are independently associated with higher frequency of blood–cerebrospinal fluid barrier dysfunction using the albumin quotient. Fluids and Barriers of the CNS, 17(1). https://doi.org/10.1186/s12987-020-0173-2
  20. "Katholisches Klinikum Bochum St. Josef Hospital Neurologie "(2021) https://www.xn--klinikumbochum-d72h.de/fuer%E2%80%90aerzte.html
  21. Rath, J., Zulehner, G., Schober, B., Grisold, A., Krenn, M., Cetin, H., & Zimprich, F. (2021). Cerebrospinal fluid analysis in Guillain–Barré syndrome: value of albumin quotients. Journal of Neurology, 268(9), 3294–3300. https://doi.org/10.1007/s00415-021-10479-9
  22. Sex Differences in Drug Disposition
  23. Wick, M., Gross, C. C., Isenmann, S., & Strik, H. (2016). Liquorzytologie: Standards, Stellenwert und moderne Methoden. Der Nervenarzt, 87(12), 1276–1281. https://doi.org/10.1007/s00115-016-0219-5
  24. Diagnostic Systems GmbH "Instructions for Use (Respons 910) Glucose Hexokinase FS "(2019) https://www.xn--diasysdiagnostics-vz2j.com/en/products/kit%E2%80%90lines/kits%E2%80%90for%E2%80%90respons/product%E2%80%90details/89%E2%80%90glucose%E2%80%90hexokinase%E2%80%90fs/product.show
  25. Diagnostic Systems GmbH "Instructions for Use (Respons 910) Lactat FS* "(2018).

1–25 of 50