Published January 6, 2023 | Journal article | Version v1 | https://doi.org/10.1007/s00270-022-03350-5

Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of Workflow and Diagnostic Quality

Description

Abstract Purpose To evaluate workflow efficiency and diagnostic quality of a free-breathing 3D stack-of-stars gradient echo (Radial GRE) sequence compared to a breath-hold 3D Cartesian gradient echo (Cartesian GRE) sequence for needle position control in MR-guided liver interventions. Materials and Methods 12 MR-guided liver interventions were performed on a 1.5 T Siemens Aera and analyzed retrospectively. 15 series of the Radial GRE sequence were compared to 14 series of the Cartesian GRE sequence regarding the time interval between two consecutive live-scans for needle tracking (Tracking-2-Tracking-Time). The quality of both sequences was compared by the SNR within comparable slices in liver and tumor ROIs. The CNR was calculated by subtraction of the SNR values. Subjective image quality scores of three radiologists were assessed and inter-rater reliability was tested by Fleiss' kappa. Values are given as mean ± SD. P-values < 0.05 were considered as significant. Results The median Tracking-2-Tracking-Time was significantly shorter for the Radial GRE sequence, 185 ± 42 s vs. 212 ± 142 s (p = 0.04) and the median SNR of the liver and tumor ROIs were significantly higher in the Radial GRE sequence, 249 ± 92 vs. 109 ± 67 (p = 0.03) and 165 ± 74 vs. 77 ± 43 (p = 0.02). CNR between tumor and liver ROIs showed a tendency to be higher for the Radial GRE sequence without significance, 68 ± 48 vs. 49 ± 32 (p = 0.28). Mean subjective image quality was 3.33 ± 1.08 vs. 2.62 ± 0.95 comparing Radial and Cartesian GRE with a Fleiss' kappa of 0.39 representing fair inter-rater reliability. Conclusion A free-breathing 3D stack-of-stars gradient echo sequence can simplify the workflow and reduce intervention time, while providing superior image quality. Under local anesthesia, it increases patient comfort and reduces potential risks for needle dislocations in MR-guided liver interventions by avoiding respiratory arrests for needle position control.

Additional details

Funding

ROR icon Siemens Healthineers (Germany)
Institutional funding
Delcath Systems, Inc.
(Institutional funding)
Promedicus Ltd.
(Institutional funding)
Medizinische Hochschule Hannover (MHH)

Dates

Issued
January 6, 2023

References

  1. Li, Z., Wang, C., Si, G., Zhou, X., Li, Y., Li, J., Jiao, D., & Han, X. (2021). Image-guided microwave ablation of hepatocellular carcinoma (≤5.0 cm): is MR guidance more effective than CT guidance?. BMC Cancer, 21(1). https://doi.org/10.1186/s12885-021-08099-7
  2. Kägebein, U., Speck, O., Wacker, F., & Hensen, B. (2018). Motion Correction in Proton Resonance Frequency–based Thermometry in the Liver. Topics in Magnetic Resonance Imaging, 27(1), 53–61. https://doi.org/10.1097/rmr.0000000000000157
  3. Block KT, Chandarana H, Fatterpekar G, Hagiwara M, Milla S, Mulholland T, et al. Improving the robustness of clinical T1-weighted MRI using radial VIBE. MAGNETOM Flash. 2013;5:6–11.
  4. Gooding, J., Werder, S. von ., Mahnken, A., & Disselhorst-Klug, C. (2012). Respiratory Motion Compensation in Image-Guided Therapies. Biomedical Engineering / Biomedizinische Technik, 57(SI-1 Track-C). https://doi.org/10.1515/bmt-2012-4302
  5. Block, K. T., Chandarana, H., Milla, S., Bruno, M., Mulholland, T., Fatterpekar, G., Hagiwara, M., Grimm, R., Geppert, C., Kiefer, B., & Sodickson, D. K. (2014). Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity. Journal of the Korean Society of Magnetic Resonance in Medicine, 18(2), 87. https://doi.org/10.13104/jksmrm.2014.18.2.87
  6. Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997). Signal‐to‐noise measurements in magnitude images from NMR phased arrays. Magnetic Resonance in Medicine, 38(5), 852–857. https://doi.org/10.1002/mrm.1910380524
  7. Landis, J. R., & Koch, G. G. (1977). The Measurement of Observer Agreement for Categorical Data. Biometrics, 33(1), 159. https://doi.org/10.2307/2529310
  8. Loeve, A. J., Al-Issawi, J., Fernandez-Gutiérrez, F., Langø, T., Strehlow, J., Haase, S., Matzko, M., Napoli, A., Melzer, A., & Dankelman, J. (2016). Workflow and intervention times of MR-guided focused ultrasound – Predicting the impact of new techniques. Journal of Biomedical Informatics, 60, 38–48. https://doi.org/10.1016/j.jbi.2016.01.001
  9. Widjaja, E., Papastavros, T., Sander, B., Snead, C., Pechlivanoglou, P., & Ferket, B. (2019). Early economic evaluation of MRI-guided laser interstitial thermal therapy (MRgLITT) and epilepsy surgery for mesial temporal lobe epilepsy. PLOS ONE, 14(11), e0224571. https://doi.org/10.1371/journal.pone.0224571
  10. Babashov V, Palimaka S, Blackhouse G, O'Reilly D. Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) for treatment of symptomatic uterine fibroids: an economic analysis. Ont Health Technol Assess Ser. 2015;15:1–61.
  11. Sedaghat, F., & Tuncali, K. (2018). Enabling Technology for MRI-Guided Intervention. Topics in Magnetic Resonance Imaging, 27(1), 5–8. https://doi.org/10.1097/rmr.0000000000000148
  12. Barkhausen, J., Kahn, T., Krombach, G., Kuhl, C., Lotz, J., Maintz, D., Ricke, J., Schönberg, S., Vogl, T., Wacker, F., & Radiology, G. A. of C. in A. (2017). White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 189(07), 611–623. https://doi.org/10.1055/s-0043-110011
  13. Deng, H.-P., Li, X.-M., Yang, L., Wang, Y., Wang, S.-Y., Zhou, P., Lu, Y.-J., Ren, J., & Wang, M. (2021). DCE-MRI of esophageal carcinoma using star-VIBE compared with conventional 3D-VIBE. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-03171-5
  14. Chandarana, H., Block, T. K., Rosenkrantz, A. B., Lim, R. P., Kim, D., Mossa, D. J., Babb, J. S., Kiefer, B., & Lee, V. S. (2011). Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence. Investigative Radiology, 46(10), 648–653. https://doi.org/10.1097/rli.0b013e31821eea45