Published September 24, 2025 | Journal article | Version v1 | https://doi.org/10.1002/viw.20250076

Breaking optical barriers: Transparent polymeric hollow fibers for biomedical applications

Description

Abstract This study presents first polymeric hollow fibers (HFs) with sufficient optical transparency for real‐time and non‐invasive monitoring of biological systems, one of the most important hurdles accounted in HF bioreactor technology. Biocompatible polymers, including polyvinylidene fluoride (PVDF), polycaprolactone, and polyacrylonitrile, were processed via dry‐jet wet spinning. A comprehensive analysis of the morphological, structural, and transport properties of the HFs provided valuable insights into their optical performance. Our findings revealed the critical interplay of HF wall thickness, porosity, polymer crystal size, and intrinsic refractive index in achieving transparency. These findings may serve as a useful guidance to produce transparent polymeric HFs with similar or different polymeric systems. Remarkably, PVDF HFs achieved over 83% transmittance, exceeding standards for in vitro cell observation, and was achieved without the presence of modifiers. As a proof of concept, labeled human cerebral microvascular endothelial cells (hCMEC/D3) were cultured within the HFs and successfully monitored in real time under both static and dynamic conditions. These transparent HFs demonstrate transformative potential, enabling real‐time decision making while significantly reducing cost and time. This cutting‐edge membrane material paves the way for advanced applications in microfluidics, mass transport studies, and biomedical research, establishing these transparent HFs as key enabling materials for strategic biomedical technologies.

Additional details

Dates

Issued
September 24, 2025

References

  1. Baker, R. W. (2004). Membrane Technology and Applications (1st ed.). Wiley. https://doi.org/10.1002/0470020393
  2. Huang, Y., Xiao, C., Huang, Q., Liu, H., & Zhao, J. (2021). Progress on polymeric hollow fiber membrane preparation technique from the perspective of green and sustainable development. Chemical Engineering Journal, 403, Article 126295. https://doi.org/10.1016/j.cej.2020.126295
  3. Wung, N., Acott, S. M., Tosh, D., & Ellis, M. J. (2014). Hollow fibre membrane bioreactors for tissue engineering applications. Biotechnology Letters, 36(12), 2357–2366. https://doi.org/10.1007/s10529-014-1619-x
  4. De Bartolo, L., Curcio, E., & Drioli, E. (2017). Membrane Systems. De Gruyter. https://doi.org/10.1515/9783110268010
  5. Pramotton, F. M., Spitz, S., & Kamm, R. D. (2024). Challenges and Future Perspectives in Modeling Neurodegenerative Diseases Using Organ‐on‐a‐Chip Technology. Advanced Science, 11(32). https://doi.org/10.1002/advs.202403892
  6. Stegemann, J., Gröniger, F., Neutsch, K., Li, H., Flavel, B. S., Metternich, J. T., Erpenbeck, L., Petersen, P. B., Hedde, P. N., & Kruss, S. (2025). High‐Speed Hyperspectral Imaging for Near Infrared Fluorescence and Environmental Monitoring. Advanced Science, 12(16), Article 2415238. https://doi.org/10.1002/advs.202415238
  7. Shan, D., Gerhard, E., Zhang, C., Tierney, J. W., Xie, D., Liu, Z., & Yang, J. (2018). Polymeric biomaterials for biophotonic applications. Bioactive Materials, 3(4), 434–445. https://doi.org/10.1016/j.bioactmat.2018.07.001
  8. Cucullo, L., Marchi, N., Hossain, M., & Janigro, D. (2010). A Dynamic in vitro BBB Model for the Study of Immune Cell Trafficking into the Central Nervous System. Journal of Cerebral Blood Flow & Metabolism, 31(2), 767–777. https://doi.org/10.1038/jcbfm.2010.162
  9. Neuhaus, W., Lauer, R., Oelzant, S., Fringeli, U. P., Ecker, G. F., & Noe, C. R. (2006). A novel flow based hollow-fiber blood–brain barrier in vitro model with immortalised cell line PBMEC/C1–2. Journal of Biotechnology, 125(1), 127–141. https://doi.org/10.1016/j.jbiotec.2006.02.019
  10. Neuhaus, W. (2020). In Vitro Models of the Blood-Brain Barrier. In Handbook of Experimental Pharmacology (pp. 75–110). Springer International Publishing. https://doi.org/10.1007/164_2020_370
  11. Williams-Medina, A., Deblock, M., & Janigro, D. (2021). In vitro Models of the Blood–Brain Barrier: Tools in Translational Medicine. Frontiers in Medical Technology, 2. https://doi.org/10.3389/fmedt.2020.623950
  12. Mantecón-Oria, M., Rivero, M. J., Diban, N., & Urtiaga, A. (2022). On the quest of reliable 3D dynamic in vitro blood-brain barrier models using polymer hollow fiber membranes: Pitfalls, progress, and future perspectives. Frontiers in Bioengineering and Biotechnology, 10. https://doi.org/10.3389/fbioe.2022.1056162
  13. Oo, Z. Y., Deng, R., Hu, M., Ni, M., Kandasamy, K., bin Ibrahim, M. S., Ying, J. Y., & Zink, D. (2011). The performance of primary human renal cells in hollow fiber bioreactors for bioartificial kidneys. Biomaterials, 32(34), 8806–8815. https://doi.org/10.1016/j.biomaterials.2011.08.030
  14. Oo, Z. Y., Kandasamy, K., Tasnim, F., & Zink, D. (2013). A novel design of bioartificial kidneys with improved cell performance and haemocompatibility. Journal of Cellular and Molecular Medicine, 17(4), 497–507. https://doi.org/10.1111/jcmm.12029
  15. Unagolla, J. M., & Jayasuriya, A. C. (2020). Hydrogel-based 3D bioprinting: A comprehensive review on cell-laden hydrogels, bioink formulations, and future perspectives. Applied Materials Today, 18, Article 100479. https://doi.org/10.1016/j.apmt.2019.100479
  16. Nguyen, H. M., Ngoc Le, T. T., Nguyen, A. T., Thien Le, H. N., & Pham, T. T. (2023). Biomedical materials for wound dressing: recent advances and applications. RSC Advances, 13(8), 5509–5528. https://doi.org/10.1039/d2ra07673j
  17. Gruppuso, M., Turco, G., Marsich, E., & Porrelli, D. (2021). Polymeric wound dressings, an insight into polysaccharide-based electrospun membranes. Applied Materials Today, 24, 101148. https://doi.org/10.1016/j.apmt.2021.101148
  18. Azevedo, R. S. S., de Sousa, J. R., Araujo, M. T. F., Martins Filho, A. J., de Alcantara, B. N., Araujo, F. M. C., Queiroz, M. G. L., Cruz, A. C. R., Vasconcelos, B. H. B., Chiang, J. O., Martins, L. C., Casseb, L. M. N., da Silva, E. V., Carvalho, V. L., Vasconcelos, B. C. B., Rodrigues, S. G., Oliveira, C. S., Quaresma, J. A. S., & Vasconcelos, P. F. C. (2018). In situ immune response and mechanisms of cell damage in central nervous system of fatal cases microcephaly by Zika virus. Scientific Reports, 8(1). https://doi.org/10.1038/s41598-017-17765-5
  19. Abrishamkar, A., Nilghaz, A., Saadatmand, M., Naeimirad, M., & deMello, A. J. (2022). Microfluidic-assisted fiber production: Potentials, limitations, and prospects. Biomicrofluidics, 16(6). https://doi.org/10.1063/5.0129108
  20. George, J., Hsu, C.-C., Nguyen, L. T. B., Ye, H., & Cui, Z. (2020). Neural tissue engineering with structured hydrogels in CNS models and therapies. Biotechnology Advances, 42, Article 107370. https://doi.org/10.1016/j.biotechadv.2019.03.009
  21. Nguyen, T. P. T., Tran, B. M., & Lee, N. Y. (2018). Microfluidic approach for the fabrication of cell-laden hollow fibers for endothelial barrier research. Journal of Materials Chemistry B, 6(38), 6057–6066. https://doi.org/10.1039/c8tb02031k
  22. Wei, Z., Wang, S., Hirvonen, J., Santos, H. A., & Li, W. (2022). Microfluidics Fabrication of Micrometer‐Sized Hydrogels with Precisely Controlled Geometries for Biomedical Applications. Advanced Healthcare Materials, 11(16). https://doi.org/10.1002/adhm.202200846
  23. Ahmad, A. L., Otitoju, T. A., & Ooi, B. S. (2019). Hollow fiber (HF) membrane fabrication: A review on the effects of solution spinning conditions on morphology and performance. Journal of Industrial and Engineering Chemistry, 70, 35–50. https://doi.org/10.1016/j.jiec.2018.10.005
  24. Ismail, A. F., Mustaffar, M. I., Illias, R. M., & Abdullah, M. S. (2006). Effect of dope extrusion rate on morphology and performance of hollow fibers membrane for ultrafiltration. Separation and Purification Technology, 49(1), 10–19. https://doi.org/10.1016/j.seppur.2005.08.001
  25. Guillen, G. R., Pan, Y., Li, M., & Hoek, E. M. V. (2011). Preparation and Characterization of Membranes Formed by Nonsolvent Induced Phase Separation: A Review. Industrial & Engineering Chemistry Research, 50(7), 3798–3817. https://doi.org/10.1021/ie101928r

1–25 of 70