Published February 1990 | Journal article | Version v1 | https://doi.org/10.1016/0010-4809(90)90003-u

Stability of computer ECG amplitude measurements in the presence of noise

Additional details

Dates

Issued
February 1990

References

  1. A review of computer ECG analysis: Time to evaluate and standardize
  2. Differences in measurement results obtained by four different ECG computer programs
  3. Willems, J. L. (1980). A plea for common standards in computer aided ECG analysis. Computers and Biomedical Research, 13(2), 120–131. https://doi.org/10.1016/0010-4809(80)90011-7
  4. Willems, J. L., Arnaud, P., van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., Meyer, J., Ritsema van Eck, H. J., Robles de Medina, E. O., & Zywietz, C. (1985). Establishment of a reference library for evaluating computer ECG measurement programs. Computers and Biomedical Research, 18(5), 439–457. https://doi.org/10.1016/0010-4809(85)90021-7
  5. Willems, J. L., Arnaud, P., Van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Graham, I., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., Meyer, J., & Zywietz, C. (1987). A reference data base for multilead electrocardiographic computer measurement programs. Journal of the American College of Cardiology, 10(6), 1313–1321. https://doi.org/10.1016/s0735-1097(87)80136-5
  6. Assessment of precision and accuracy of computer programs for analysis of electrocardiograms
  7. The influence of noise on ECG computer measurements and interpretations
  8. Diagnostic accuracy in computerized analysis of non-optimum ECG signals
  9. Statistical processing methods for recognition, and classification of vectorcardiograms
  10. Methods for noise testing of ECG analysis programs
  11. Results of ECG program noise test within the CSE project
  12. Noise tolerance in ECG computer programs and measurement stability of minimum waves. A summary of results from CSE noise tests and conclusions
  13. Stability of ECG amplitude measurements in systematic noise tests. Results and recommendations from the CSE Project
  14. Willems, J. L., Zywietz, C., Arnaud, P., van Bemmel, J. H., Degani, R., & Macfarlane, P. W. (1987). Influence of noise on wave boundary recognition by ECG measurement programs. Computers and Biomedical Research, 20(6), 543–562. https://doi.org/10.1016/0010-4809(87)90025-5
  15. Borovsky, D., & Zywietz, C. (2015). Accuracy and Beat-to-Beat Variation in ECG Computer Measurements1. In Advances in Cardiology (pp. 176–181). S. Karger AG. https://doi.org/10.1159/000398391
  16. Fischmann, E., Cosma, J., & Pipberger, H. V. (1968). Beat to beat and observer variation of the electrocardiogram. American Heart Journal, 75(4), 465–473. https://doi.org/10.1016/0002-8703(68)90005-7
  17. BAILEY, J. J., ITSCOITZ, S. B., HIRSHFELD, J. W., GRAUER, L. E., & HORTON, M. R. (1974). A Method for Evaluating Computer Programs for Electrocardiographic Interpretation. Circulation, 50(1), 73–79. https://doi.org/10.1161/01.cir.50.1.73
  18. BAILEY, J. J., ITSCOITZ, S. B., GRAUER, L. E., HIRSHEFELD, J. W., & HORTON, M. R. (1974). A Method for Evaluating Computer Programs for Electrocardiographic Interpretation. Circulation, 50(1), 80–87. https://doi.org/10.1161/01.cir.50.1.80
  19. Bailey, J. J., Horton, M., & Itscoitz, S. B. (1976). The importance of reproducibility testing of computer programs for electrocardiographic interpretation: Application to the automatic vectorcardiographic analysis program (AVA 3.4). Computers and Biomedical Research, 9(4), 307–316. https://doi.org/10.1016/0010-4809(76)90053-7
  20. Evaluation methodologies for ECG diagnostic systems
  21. Combining measurement precision and fuzzy diagnostic criteria
  22. A new approach to determine the sampling rate for ECGs
  23. An investigation on ECG variabilities by using highly resolved digital data
  24. Frequenzanalyse einzelner Komplexe des Säuglings-EKG
  25. Barr, R. C., & Spach, M. S. (1977). Sampling rates required for digital recording of intracellular and extracellular cardiac potentials. Circulation, 55(1), 40–48. https://doi.org/10.1161/01.cir.55.1.40

1–25 of 30

Citations

  1. https://doi.org/10.70675/63dfdff7z3089z4c3fza0e6zb37190978097
  2. Krupaviciute, A. (2026). Personalised wearable cardiac sensor services for pervasive self-care [Agence Bibliographique de l'Enseignement Supérieur]. In Lyon, INSA. https://doi.org/10.70675/e7c9a0c8za90dz487dzb351z7e61e77fe2d6
  3. https://doi.org/10.3390/hearts2030032
  4. https://doi.org/10.1109/icassp.2019.8683084
  5. https://doi.org/10.23919/eusipco.2019.8903153
  6. Fakhri, Y., Melgaard, J., Andersson, H. B., Schoos, M. M., Birnbaum, Y., Graff, C., Sejersten, M., Kastrup, J., & Clemmensen, P. (2018). Automatic electrocardiographic algorithm for assessing severity of ischemia in ST-segment elevation myocardial infarction. International Journal of Cardiology, 268, 18–22. https://doi.org/10.1016/j.ijcard.2018.04.057
  7. Waits, G. S., & Soliman, E. Z. (2017). Digitizing paper electrocardiograms: Status and challenges. Journal of Electrocardiology, 50(1), 123–130. https://doi.org/10.1016/j.jelectrocard.2016.09.007
  8. Braendlein, M., Lonjaret, T., Leleux, P., Badier, J., & Malliaras, G. G. (2016). Voltage Amplifier Based on Organic Electrochemical Transistor. Advanced Science, 4(1), Article 1600247. https://doi.org/10.1002/advs.201600247
  9. Rijnbeek, P. R., van Herpen, G., Bots, M. L., Man, S., Verweij, N., Hofman, A., Hillege, H., Numans, M. E., Swenne, C. A., Witteman, J. C. M., & Kors, J. A. (2014). Normal values of the electrocardiogram for ages 16–90 years. Journal of Electrocardiology, 47(6), 914–921. https://doi.org/10.1016/j.jelectrocard.2014.07.022
  10. Xue, J., & Rowlandson, I. (2013). The detection of T-wave variation linked to arrhythmic risk: An industry perspective. Journal of Electrocardiology, 46(6), 597–607. https://doi.org/10.1016/j.jelectrocard.2013.08.012
  11. Kors, J. A., & van Herpen, G. (2011). Computer Analysis of the Electrocardiogram. In Specialized Aspects of ECG (pp. 303–347). Springer London. https://doi.org/10.1007/978-0-85729-880-5_5
  12. Kors, J. A., & van Herpen, G. (2010). Computer Analysis of the Electrocardiogram. In Comprehensive Electrocardiology (pp. 1721–1765). Springer London. https://doi.org/10.1007/978-1-84882-046-3_37
  13. Rosenthal, J. E. (2010). Electrocardiography. In Practical Signal and Image Processing in Clinical Cardiology (pp. 113–131). Springer London. https://doi.org/10.1007/978-1-84882-515-4_10
  14. Schijvenaars, B. J. A., van Herpen, G., & Kors, J. A. (2008). Intraindividual variability in electrocardiograms. Journal of Electrocardiology, 41(3), 190–196. https://doi.org/10.1016/j.jelectrocard.2008.01.012
  15. https://doi.org/10.1109/cic.2008.4749076
  16. Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., Pahlm, O., Rautaharju, P., & Wagner, G. S. (2007). Recommendations for the standardization and interpretation of the electrocardiogram. Heart Rhythm, 4(3), 394–412. https://doi.org/10.1016/j.hrthm.2007.01.027
  17. Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., Pahlm, O., Rautaharju, P., & Wagner, G. S. (2007). Recommendations for the Standardization and Interpretation of the Electrocardiogram. Journal of the American College of Cardiology, 49(10), 1109–1127. https://doi.org/10.1016/j.jacc.2007.01.024
  18. Fayn, J., Rubel, P., & Macfarlane, P. W. (2007). Can the lessons learned from the assessment of automated electrocardiogram analysis in the Common Standards for quantitative Electrocardiography study benefit measurement of delayed contrast-enhanced magnetic resonance images?. Journal of Electrocardiology, 40(3), 246–250. https://doi.org/10.1016/j.jelectrocard.2007.02.010
  19. https://doi.org/10.1161/circulationaha.106.180200
  20. Kligfield, P., Hancock, E. W., Helfenbein, E. D., Dawson, E. J., Cook, M. A., Lindauer, J. M., Zhou, S. H., & Xue, J. (2006). Relation of QT Interval Measurements to Evolving Automated Algorithms from Different Manufacturers of Electrocardiographs. The American Journal of Cardiology, 98(1), 88–92. https://doi.org/10.1016/j.amjcard.2006.01.060
  21. https://doi.org/10.1186/1471-2261-5-29
  22. Bulygin, V. P., & Chepaikin, A. G. (2002). Interpretation Medical Devices. Biomedical Engineering, 36(2), 73–79. https://doi.org/10.1023/a:1016335921433
  23. https://doi.org/10.1109/cic.1990.144192
  24. https://doi.org/10.1109/cic.1995.482660
  25. de Bruyne, M. C., Kors, J. A., Visentin, S., van Herpen, G., Hoes, A. W., Grobbee, D. E., & van Bemmel, J. H. (1998). Reproducibility of computerized ecg measurements and coding in a nonhospitalized elderly population. Journal of Electrocardiology, 31(3), 189–195. https://doi.org/10.1016/s0022-0736(98)90133-9

1–25 of 32