A Novel Method for Clinical Cochlear Duct Length Estimation toward Patient‐Specific Cochlear Implant Selection
Authors/Creators
-
1.
Medizinische Hochschule Hannover
- 2. Department of Otolaryngology Hannover Medical School Hannover Germany
-
3.
Hearing4all
- 4. MED‐EL Medical Electronics Hannover Research Center Hannover Germany
Description
ObjectiveIn the field of cochlear implantation, the current trend toward patient‐specific electrode selection and the achievement of optimal audiologic outcomes has resulted in implant manufacturers developing a large portfolio of electrodes. The aim of this study was to bridge the gap between the known variability of cochlea length and this electrode portfolio.DesignRetrospective analysis on cochlear length and shape in micro–computed tomography and cone beam computed tomography data.SettingTertiary care medical center.Subjects and MethodsA simple 2‐step approach was developed to accurately estimate the individual cochlear length as well as the projected length of an electrode array inside the cochlea. The method is capable of predicting the length of the cochlea and the inserted electrode length at any specific angle. Validation of the approach was performed with 20 scans of human temporal bones (micro–computed tomography) and 47 pre‐ and postoperative clinical scans (cone beam computed tomography).ResultsMean ± SD absolute errors in cochlear length estimations were 0.12 ± 0.10 mm, 0.38 ± 0.26 mm, and 0.71 ± 0.43 mm for 1, 1.5, and 2 cochlea turns, respectively. Predicted insertion angles based on clinical cone beam computed tomography data showed absolute deviations of 27° ± 18° to the corresponding postoperative measurements.ConclusionWith accuracy improvements of 80% to 90% in comparison with previously proposed approaches, the method is well suited for the use in individualized cochlear implantation.
Additional details
Identifiers
Dates
- Issued
-
October 2018
References
- O'Connell, B. P., Cakir, A., Hunter, J. B., Francis, D. O., Noble, J. H., Labadie, R. F., Zuniga, G., Dawant, B. M., Rivas, A., & Wanna, G. B. (2016). Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otology & Neurotology, 37(8), 1016–1023. https://doi.org/10.1097/mao.0000000000001125
- O'Connell, B. P., Hunter, J. B., Haynes, D. S., Holder, J. T., Dedmon, M. M., Noble, J. H., Dawant, B. M., & Wanna, G. B. (2017). Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. The Laryngoscope, 127(10), 2352–2357. https://doi.org/10.1002/lary.26467
- Hochmair, I., Arnold, W., Nopp, P., Jolly, C., Roland, P., & Müller, J. (2003). Deep Electrode Insertion in Cochlear Implants: Apical Morphology, Electrodes and Speech Perception Results. Acta Oto-Laryngologica, 123(5), 612–617. https://doi.org/10.1080/000164803100001844
- Büchner, A., Illg, A., Majdani, O., Lenarz, T., & Malmierca, M. S. (2017). Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis. PLOS ONE, 12(5), e0174900. https://doi.org/10.1371/journal.pone.0174900
- Buchman, C. A., Dillon, M. T., King, E. R., Adunka, M. C., Adunka, O. F., & Pillsbury, H. C. (2014). Influence of Cochlear Implant Insertion Depth on Performance. Otology & Neurotology, 35(10), 1773–1779. https://doi.org/10.1097/mao.0000000000000541
- Adunka, O., & Kiefer, J. (2006). Impact of electrode insertion depth on intracochlear trauma. Otolaryngology–Head and Neck Surgery, 135(3), 374–382. https://doi.org/10.1016/j.otohns.2006.05.002
- Suhling, M.-C., Majdani, O., Salcher, R., Leifholz, M., Büchner, A., Lesinski-Schiedat, A., & Lenarz, T. (2016). The Impact of Electrode Array Length on Hearing Preservation in Cochlear Implantation. Otology & Neurotology, 37(8), 1006–1015. https://doi.org/10.1097/mao.0000000000001110
- Meng, J., Li, S., Zhang, F., Li, Q., & Qin, Z. (2016). Cochlear Size and Shape Variability and Implications in Cochlear Implantation Surgery. Otology & Neurotology, 37(9), 1307–1313. https://doi.org/10.1097/mao.0000000000001189
- Würfel, W., Lanfermann, H., Lenarz, T., & Majdani, O. (2014). Cochlear length determination using Cone Beam Computed Tomography in a clinical setting. Hearing Research, 316, 65–72. https://doi.org/10.1016/j.heares.2014.07.013
- Hardy, M. (1938). The length of the organ of Corti in man. American Journal of Anatomy, 62(2), 291–311. https://doi.org/10.1002/aja.1000620204
- Schurzig, D., Timm, M. E., Lexow, G. J., Majdani, O., Lenarz, T., & Rau, T. S. (2018). Cochlear helix and duct length identification – Evaluation of different curve fitting techniques. Cochlear Implants International, 19(5), 268–283. https://doi.org/10.1080/14670100.2018.1460025
- Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006). The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes. Audiology and Neurotology, 11(Suppl. 1), 27–33. https://doi.org/10.1159/000095611
- Alexiades, G., Dhanasingh, A., & Jolly, C. (2015). Method to Estimate the Complete and Two-Turn Cochlear Duct Length. Otology & Neurotology, 36(5), 904–907. https://doi.org/10.1097/mao.0000000000000620
- Lexow, G. J., Schurzig, D., Gellrich, N.-C., Lenarz, T., Majdani, O., & Rau, T. S. (2016). Visualization, measurement and modelling of the cochlea using rotating midmodiolar slice planes. International Journal of Computer Assisted Radiology and Surgery, 11(10), 1855–1869. https://doi.org/10.1007/s11548-016-1374-7
- Schurzig, D., Lexow, G. J., Majdani, O., Lenarz, T., & Rau, T. S. (2016). Three-dimensional modeling of the cochlea by use of an arc fitting approach. Computer Methods in Biomechanics and Biomedical Engineering, 19(16), 1785–1799. https://doi.org/10.1080/10255842.2016.1188921
- Pietsch, M., Aguirre Dávila, L., Erfurt, P., Avci, E., Lenarz, T., & Kral, A. (2017). Spiral Form of the Human Cochlea Results from Spatial Constraints. Scientific Reports, 7(1). https://doi.org/10.1038/s41598-017-07795-4
- Rask‐Andersen, H., Liu, W., Erixon, E., Kinnefors, A., Pfaller, K., Schrott‐Fischer, A., & Glueckert, R. (2012). Human Cochlea: Anatomical Characteristics and their Relevance for Cochlear Implantation. The Anatomical Record, 295(11), 1791–1811. https://doi.org/10.1002/ar.22599
- Sakellarios, A. I., Tachos, N. S., Rigas, G., Bibas, T., Ni, G., Böhnke, F., & Fotiadis, D. I. (2017). A validated methodology for the 3D reconstruction of cochlea geometries using human microCT images. Measurement Science and Technology, 28(5), 054001. https://doi.org/10.1088/1361-6501/aa5f18
- Liu, Y.-K., Qi, C.-L., Tang, J., Jiang, M.-L., Du, L., Li, Z.-H., Tan, S.-H., & Tang, A.-Z. (2016). The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformation. Acta Oto-Laryngologica, 137(2), 119–126. https://doi.org/10.1080/00016489.2016.1221132
- Rivas, A., Cakir, A., Hunter, J. B., Labadie, R. F., Zuniga, M. G., Wanna, G. B., Dawant, B. M., & Noble, J. H. (2017). Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays. Otology & Neurotology, 38(3), 339–346. https://doi.org/10.1097/mao.0000000000001329
- Lexow, G. J., Kluge, M., Gellrich, N.-C., Lenarz, T., Majdani, O., & Rau, T. S. (2018). On the accuracy of cochlear duct length measurement in computed tomographic images. European Archives of Oto-Rhino-Laryngology, 275(5), 1077–1085. https://doi.org/10.1007/s00405-018-4930-7
- Greenwood, D. D. (1990). A cochlear frequency-position function for several species—29 years later. The Journal of the Acoustical Society of America, 87(6), 2592–2605. https://doi.org/10.1121/1.399052
Citations
- Rybarczyk, J. A., Bratu, E. L., Labadie, R. F., & Noble, J. H. (2026). Simulation of apically grounded cochlear implant stimuli using neural stimulation models. International Journal of Computer Assisted Radiology and Surgery, 21(11), 2277–2285. https://doi.org/10.1007/s11548-026-03702-3
- Bircher, B., Aebischer, P., Wimmer, W., Mantokoudis, G., Schraivogel, S., Caversaccio, M., & Weder, S. (2026). A clinical shift toward personalized cochlear implantation: Using preoperative planning to optimize insertion depth. American Journal of Otolaryngology, 47(1), 104777. https://doi.org/10.1016/j.amjoto.2025.104777
- Agrawal, S. K., Li, H., Spedaliere, C., Rask‐Andersen, H., & Ladak, H. M. (2026). The cochlear morphometry compendium: High‐resolution synchrotron measurements and normative reference values. Journal of Anatomy, 249(6), 1290–1308. https://doi.org/10.1111/joa.70175
- Deurwaerdère, A. D., Gimenez, T., Péan, V., Valognes, P., & Bonnard, D. (2026). Anatomy-Based Fitting for Cochlear Implants: Evaluation of Hearing Performance in Newly Implanted Cochlear Implant Users - A Randomized Clinical Trial. Clinical and Experimental Otorhinolaryngology. https://doi.org/10.21053/ceo.2025-00251
- Sahara, T., Hoshi, Y., Mori, A., Koyama, H., Osaki, Y., Nakajima, W., Fujita, T., Kashio, A., & Doi, K. (2026). Longitudinal Correlation of Frequency-to-Place Mismatch and Postoperative Speech Perception Outcomes in Cochlear Implant Recipients: Monosyllable, Consonant, Word, and Sentence. Audiology Research, 16(2), 56. https://doi.org/10.3390/audiolres16020056
- Wang, F., Anaghan, D., Dhanasingh, A., & Hui, L. (2025). Clinical Validation of Manual Measurement of Cochlea Length With Post‐Operative Electrode Insertion Depth: A Pilot Study. Laryngoscope Investigative Otolaryngology, 10(4), Article e70237. https://doi.org/10.1002/lio2.70237
- Alahmadi, A., Almuhawas, F., Alshalan, A., Shami, I., Hajr, E., Abdelsamad, Y., & Alsanosi, A. (2025). Radiation-free automatic planning for cochlear implantation: Comparing cochlear duct lengths between CT and MRI. Brazilian Journal of Otorhinolaryngology, 91(4), 101582. https://doi.org/10.1016/j.bjorl.2025.101582
- Luitel, S. S., Malhotra, M., Priya, M., Bhardwaj, A., Timmaraju, S., Sharma, P., Bhattarai, S., & Mishra, S. (2025). Measuring the cochlea: comparison between otoplan and curved multiplanar reconstruction and literature review. The Journal of Laryngology & Otology, 139(10), 891–896. https://doi.org/10.1017/s0022215125102934
- Hussain, R., Patou, F., Calixto, R., Matti, I.-M., & Dietz, A. (2025). A histological validation of an automatic cochlear implant electrode placement assessment from clinical computed tomography images. Cochlear Implants International, 26(5), 341–348. https://doi.org/10.1080/14670100.2025.2581945
- Andonie, R. R., Wimmer, W., Wildhaber, R. A., Mantokoudis, G., Caversaccio, M., & Weder, S. (2025). Electrocochleography Latency: Correlation With Electrode Position During Cochlear Implantation. Ear & Hearing, 46(5), 1130–1140. https://doi.org/10.1097/aud.0000000000001652
- Schmidt, F. H., Zhang, L., Glabasnia, M. W., Schurzig, D., Ehrt, K., Cantré, D., van Bonn-Ytrehus, S. M., Großmann, W., & Mlynski, R. (2025). Systematic Overestimation of the Angular Insertion Depth of Electrode Arrays in Cochlear Implantation (CI) Patients with Small Cochlea by Imaging Processing Software. Otology & Neurotology, 46(10), 1228–1235. https://doi.org/10.1097/mao.0000000000004294
- Avallone, E., Timm, M. E., Lenarz, T., & Schurzig, D. (2025). Investigation of Automated Cochlear Length and Cochlear Implant Insertion Angle Predictions with a Surgical Planning Platform. Otology & Neurotology, 46(5), e161–e169. https://doi.org/10.1097/mao.0000000000004480
- Schmidt, F. H., Glabasnia, M. W., Cantré, D., Ehrt, K., van Bonn-Ytrehus, S. M., Saur, A.-L., Großmann, W., Mlynski, R., & Zhang, L. (2025). Measurement of Cochlear Dimensions Using the Transimpedance Matrix. Otology & Neurotology, 47(3), e529–e538. https://doi.org/10.1097/mao.0000000000004750
- Canfarotta, M. W., Moberly, A. C., Patro, A., Du, L., Holder, J. T., Jan, T. A., Tawfik, K. O., O'Malley, M. R., Bennett, M. L., Haynes, D. S., & Perkins, E. L. (2025). A Within-Subject Comparison of Hearing Preservation Outcomes for Bilateral Cochlear Implant Recipients. Otology & Neurotology, 47(3), 487–492. https://doi.org/10.1097/mao.0000000000004801
- Schraivogel, S., Weder, S., Mantokoudis, G., Caversaccio, M., & Wimmer, W. (2025). Predictive Models for Radiation-Free Localization of Cochlear Implants' Most Basal Electrode Using Impedance Telemetry. IEEE Transactions on Biomedical Engineering, 72(4), 1453–1464. https://doi.org/10.1109/tbme.2024.3509527
- Pai, I., Shetty, A., Pradeep, G., Komninos, C., Bergeles, C., Ourselin, S., & Connor, S. (2025). Estimation of Angular Insertion Depth of a Cochlear Implant Electrode Array: Three-Dimensional Reconstruction Versus Spiral Formulae. Clinical and Experimental Otorhinolaryngology, 18(4), 339–348. https://doi.org/10.21053/ceo.2025-00043
- Büchner, A., Weller, T., Penninger, R. T., Helpard, L., Ladak, H. M., Agrawal, S., Lenarz, T., & Schurzig, D. (2025). The Greenwood function shows close alignment with pitch perceived by cochlear implant patients with long, flexible electrode arrays and fine-structure stimulation. Frontiers in Neuroscience, 19. https://doi.org/10.3389/fnins.2025.1624499
- Alsabellha, R. M., Al Rayyes, N., Al Sabilah, R., Al Ruwaili, A., Mlata, F., & Najeeb, S. (2025). Test Electrode-Based Estimation of Achievable Insertion Depth in Cochlear Implantation. Journal of Visualized Experiments, (221). https://doi.org/10.3791/68373
- George, R., George, A., Sajitha, K., Raju, N. K., & Alex, L. (2025). Cochlear Duct Length Variability in the South Indian Population using High-resolution Computed Tomography Temporal Bone. National Journal of Clinical Anatomy, 14(4), 191–195. https://doi.org/10.4103/njca.njca_202_25
- Canfarotta, M. W., Dillon, M. T., Selleck, A. M., & Brown, K. D. (2024). Scala Tympani Volume Influences Initial 6‐Month Hearing Preservation With Lateral Wall Electrode Arrays. The Laryngoscope, 135(5), 1781–1787. https://doi.org/10.1002/lary.31917
- Çelik, M., Orhan, K. S., & Topsakal, V. (2024). Radiological Evaluation in Cochlear Implant. In Comprehensive ENT (pp. 531–547). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-77370-9_25
- Kara, E., Cögen, T., & Rubinstein, J. T. (2024). Cochlear Implants: Future Directions. In Comprehensive ENT (pp. 597–628). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-77370-9_28
- Müller-Graff, F.-T., Spahn, B., Herrmann, D. P., Kurz, A., Völker, J., Hagen, R., & Rak, K. (2024). Comprehensive literature review on the application of the otological surgical planning software OTOPLAN® for cochlear implantation. HNO, 72(S2), 89–100. https://doi.org/10.1007/s00106-023-01417-4
- Müller-Graff, F.-T., Spahn, B., Herrmann, D. P., Kurz, A., Voelker, J., Hagen, R., & Rak, K. (2024). Umfassender Literaturüberblick über die Anwendung der otologisch-chirurgischen Planungssoftware OTOPLAN® bei der Cochleaimplantation. HNO, 72(10), 687–701. https://doi.org/10.1007/s00106-024-01461-8
- Müller-Graff, F.-T., von Düring, J., Voelker, J., Al-Tinawi, F., Hagen, R., Neun, T., Hackenberg, S., & Rak, K. (2024). Verbesserte radiologische Darstellung kongenitaler Auralatresien mittels „flat-panel volume CT“. HNO, 72(11), 815–824. https://doi.org/10.1007/s00106-024-01511-1
1–25 of 105