Silicon Carbide-Coated Stents: Clinical Experience in Coronary Lesions with Increased Thrombotic Risk
Description
Purpose: To report the results of a prospective, nonrandomized, multicenter study of a semiconductor-coated stent in coronary lesions at high risk for stent thrombosis. Methods: A balloon-expandable tantalum stent was coated with silicon carbide to enhance thromboresistance (Tensum). Patients were enrolled in an observational study that compared coronary stenting with the Tensum stent in patients at low risk for stent thrombosis against those with factors predisposing to local thrombosis (acute myocardial infarction, small vessel diameter, recanalized chronic total occlusion, saphenous vein bypass grafts, and coronary allograft vascular disease). Results: In 294 patients with 364 coronary lesions, 111 patients with 142 lesions were assigned to the high-risk group. Overall, 406 Tensum stents were implanted (94% procedural success) using antiplatelet medication only after the procedure. The stent thrombosis rate (2.7% overall) in the high-risk group (3.6%) was not significantly different from that of the low-risk patients (2.1%). Conclusions: Silicon carbide coating on coronary stents may inhibit acute/subacute stent thrombosis even in patients at high risk. Randomized trials are underway for further evaluation of this promising coated stent.
Additional details
Identifiers
Dates
- Issued
-
February 1998
References
- Bittl, J. A. (1996). Coronary stent occlusion: Thrombus horribilis. Journal of the American College of Cardiology, 28(2), 368–370. https://doi.org/10.1016/0735-1097(96)00183-0
- Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995). Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance. Circulation, 91(6), 1676–1688. https://doi.org/10.1161/01.cir.91.6.1676
- Serruys, P. W., Emanuelsson, H., van der Giessen, W., Lunn, A. C., Kiemeney, F., Macaya, C., Rutsch, W., Heyndrickx, G., Suryapranata, H., Legrand, V., Goy, J. J., Materne, P., Bonnier, H., Morice, M.-C., Fajadet, J., Belardi, J., Colombo, A., Garcia, E., Ruygrok, P., … Morel, M.-A. (1996). Heparin-Coated Palmaz-Schatz Stents in Human Coronary Arteries. Circulation, 93(3), 412–422. https://doi.org/10.1161/01.cir.93.3.412
- Bolz, A., & Schaldach, M. (1992). Physikalische Mechanismen der Festkörper-Protein-Wechselwirkung an der Phasengrenze a-SiC:H-Fibrinogen - Physical Mechanisms of Solid-Protein Interactions at the Interface between Amorphous Silicon Carbide and Fibrinogen. Biomedical Engineering / Biomedizinische Technik, 37(11), 244–253. https://doi.org/10.1515/bmte.1992.37.11.244
- Strauss, B. H., Rensing, B. J., Den Boer, A., Van Der Giessen, W. J., Reiber, J. H. C., & Serruys, P. W. (1991). Do stents interfere with the densitometric assessment of a coronary artery lesion?. Catheterization and Cardiovascular Diagnosis, 24(4), 259–264. https://doi.org/10.1002/ccd.1810240408
- Mak, K.-H., Belli, G., Ellis, S. G., & Moliterno, D. J. (1996). Subacute stent thrombosis: Evolving issues and current concepts. Journal of the American College of Cardiology, 27(2), 494–503. https://doi.org/10.1016/0735-1097(95)00466-1
- Karrillon, G. J., Morice, M. C., Benveniste, E., Bunouf, P., Aubry, P., Cattan, S., Chevalier, B., Commeau, P., Cribier, A., Eiferman, C., Grollier, G., Guerin, Y., Henry, M., Lefevre, T., Livarek, B., Louvard, Y., Marco, J., Makowski, S., Monassier, J. P., … Zemour, G. (1996). Intracoronary Stent Implantation Without Ultrasound Guidance and With Replacement of Conventional Anticoagulation by Antiplatelet Therapy. Circulation, 94(7), 1519–1527. https://doi.org/10.1161/01.cir.94.7.1519
- Eeckhout, E., Kappenberger, L., & Goy, J.-J. (1996). Stents for intracoronary placement: Current status and future directions. Journal of the American College of Cardiology, 27(4), 757–765. https://doi.org/10.1016/0735-1097(95)00548-4
- Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., Cleman, M., Heuser, R., Almond, D., Teirstein, P. S., Fish, R. D., Colombo, A., Brinker, J., Moses, J., Shaknovich, A., … Goldberg, S. (1994). A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease. New England Journal of Medicine, 331(8), 496–501. https://doi.org/10.1056/nejm199408253310802
Citations
- Sun, Z. (2004). Transrenal Fixation of Aortic Stent-Grafts:Current Status and Future Directions. Journal of Endovascular Therapy, 11(5), 539–549. https://doi.org/10.1583/04-1212.1
- Thierry, B., & Tabrizian, M. (2003). Biocompatibility and Biostability of Metallic Endovascular Implants: State of the Art and Perspectives. Journal of Endovascular Therapy, 10(4), 807–824. https://doi.org/10.1177/152660280301000419
- https://doi.org/10.1583/1545-1550(2003)010%3c0807:babome%3e2.0.co;2