IFCC primary reference procedure for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 10: Reference procedure for the measurement of catalytic concentration of pancreatic α-amylase
Authors/Creators
Staaden, Antje 1, 2
Canalias, Francesca 3
Ceriotti, Ferruccio 4
Infusino, Ilenia 5, 6
Veuger, Marjan 7
Weber, Friederike
Grote-Koska, Denis 1, 2
Show affiliations
Additional details
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase
IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C, part 6. Reference procedure for the measurement ofCatalytic concentration of γ-Glutamyltransferase
Schumann, G., Aoki, R., Ferrero, C. A., Ehlers, G., Férard, G., Gella, F.-J., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kytzia, H.-J., Lessinger, J.-M., Miller, W. G., Nagel, R., Pauwels, J., Schimmel, H., Siekmann, L., Weidemann, G., Yoshida, K., & Ceriotti, F. (2006). IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): Scientific Division, Committee on Reference Systems for Enzymes (C-RSE): Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase: [α-Amylase: 1,4-α-D-glucan 4-glucanohydrolase (AMY), EC 3.2.1.1]. Clinical Chemistry and Laboratory Medicine (CCLM) , 44 (9).
https://doi.org/10.1515/cclm.2006.212
Schumann, G., Klauke, R., Canalias, F., Bossert-Reuther, S., F.H. Franck, P., Gella, F.-J., J. Jørgensen, P., Kang, D., Lessinger, J.-M., Panteghini, M., & Ceriotti, F. (2011). IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: Reference procedure for the measurement of catalytic concentration of alkaline phosphatase. Clinical Chemistry and Laboratory Medicine , 49 (9).
https://doi.org/10.1515/cclm.2011.621
Infusino, I., Schumann, G., Ceriotti, F., & Panteghini, M. (2010). Standardization in clinical enzymology: a challenge for the theory of metrological traceability. Cclm , 48 (3), 301–307.
https://doi.org/10.1515/cclm.2010.075
An approach for more precise statements of metrological traceability on reference material certificates, Accred
Gerber, M., Naujoks, K., Lenz, H., & Wulff, K. (1987). A monoclonal antibody that specifically inhibits human salivary alpha-amylase. Clinical Chemistry , 33 (7), 1158–1162.
https://doi.org/10.1093/clinchem/33.7.1158
Rauscher, E., & Gerber, M. (1989). Pancreatic α-amylase assay employing the synergism of two monoclonal antibodies. Clinica Chimica Acta , 183 (1), 41–44.
https://doi.org/10.1016/0009-8981(89)90270-2
Junge, W., Troge, B., Klein, G., Poppe, W., & Gerber, M. (1989). Evaluation of a new assay for pancreatic amylase: Performance characteristics and estimation of reference intervals. Clinical Biochemistry , 22 (2), 109–114.
https://doi.org/10.1016/s0009-9120(89)80007-4
Junge, W., Wortmann, W., Wilke, B., Waldenström, J., Kurrle-Weittenhiller, A., Finke, J., & Klein, G. (2001). Development and evaluation of assays for the determination of total and pancreatic amylase at 37°C according to the principle recommended by the IFCC. Clinical Biochemistry , 34 (8), 607–615.
https://doi.org/10.1016/s0009-9120(01)00278-8
Panteghini, M., Ceriotti, F., Schumann, G., & Siekmann, L. (2001). Establishing a Reference System in Clinical Enzymology. Clinical Chemistry and Laboratory Medicine , 39 (9).
https://doi.org/10.1515/cclm.2001.131
Catalytic concentration of alpha-amylase determined by IFCC reference method at 37 °C, IRMM/IFCC-456
Panteghini, M., & Ceriotti, F. (2012). Obtaining reference intervals traceable to reference measurement systems: is it possible, who is responsible, what is the strategy?. Clinical Chemistry and Laboratory Medicine , 50 (5).
https://doi.org/10.1515/cclm.2011.828
Witt, K., Wolf, H. U., Heuck, C., Kammel, M., Kummrow, A., & Neukammer, J. (2013). Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood. Metrologia , 50 (5), 539–548.
https://doi.org/10.1088/0026-1394/50/5/539
Mielenz, K. D., & Eckerle, K. L. (1972). Spectrophotometer Linearity Testing Using the Double-Aperture Method. Applied Optics , 11 (10), 2294.
https://doi.org/10.1364/ao.11.002294
Khanolkar, M. M., Sirsat, A. V., Bhansali, M. S., Jagannath, P., & Desouza, L. J. (1996). Studies on serum amylases in carcinoma of liver, biliary tract and pancreas. Indian Journal of Clinical Biochemistry , 11 (1), 26–31.
https://doi.org/10.1007/bf02868407
Szőke, D., Ridolfo, A., Valente, C., Galli, M., & Panteghini, M. (2015). Frequency of Pancreatic Hyperamylasemia in Human Immunodeficiency Virus–Positive Patients in the Highly Active Antiretroviral Therapy Era. American Journal of Clinical Pathology , 145 (1), 128–133.
https://doi.org/10.1093/ajcp/aqv020
Traceability, reference systems and result comparability
Braga, F., Infusino, I., & Panteghini, M. (2015). Performance criteria for combined uncertainty budget in the implementation of metrological traceability. Clinical Chemistry and Laboratory Medicine (CCLM) , 53 (6).
https://doi.org/10.1515/cclm-2014-1240
Panteghini, M., Camara, J. E., Delatour, V., Van Uytfanghe, K., Vesper, H. W., & Zhang, T. (2024). Feasibility of Metrological Traceability Implementation Using the Joint Committee on Traceability in Laboratory Medicine Database Entries Including the Fulfillment of "Fit-for-Purpose" Maximum Allowable Measurement Uncertainty. Clinical Chemistry , 70 (11), 1321–1333.
https://doi.org/10.1093/clinchem/hvae131