Published October 5, 2023 | Journal article | Version v1 | https://doi.org/10.1177/15910199231205047

Early clinical experience with the new generation Pipeline Vantage flow diverter in the treatment of unruptured saccular aneurysms using short-term dual antiplatelet therapy

Description

Purpose The Pipeline Vantage flow diverter with Shield technology (PV) used in this study is a 4th-generation flow diverter (FD) designed to reduce thrombogenicity, promote endothelialization of the implant and increase efficiency in achieving aneurysm closure. In this study, we report the aneurysm occlusion rate, complication rate and clinical outcome with short-term dual antiplatelet therapy (DAPT) in the treatment of unruptured intracranial saccular aneurysms using the PV. Methods We retrospectively identified patients treated between September 2021 and January 2023 with the PV and subsequently underwent short-term DAPT for 3 months. Patient and aneurysm characteristics, peri- and post-procedural complications, clinical outcomes and the grade of aneurysm occlusion were documented. Results Thirty patients with 32 aneurysms were treated. Successful FD implantation was achieved in all cases (100%). No periprocedural complications were documented. The overall symptomatic complication rate was 10% and the neurologic, treatment-related symptomatic complication rate was 6.6%. Only one symptomatic complication (3.3%) was device-related. Permanent clinical deterioration occurred in 2/30 patients (6.6%), leading to deterioration of the mRS within the first 3 months after treatment. No mortality was documented. The rate of complete aneurysm occlusion after 3 months and after a mean imaging follow-up of 9.9 months was 65.6% and 75%, respectively. Conclusion Implantation of the PV for the treatment of saccular intracranial aneurysms achieves a good aneurysm occlusion rate with a low rate of complications. In addition, the use of short-term DAPT after PV implantation appears to be safe.

Additional details

Dates

Issued
October 5, 2023

References

  1. Anzai, H., Falcone, J.-L., Chopard, B., Hayase, T., & Ohta, M. (2014). Optimization of Strut Placement in Flow Diverter Stents for Four Different Aneurysm Configurations. Journal of Biomechanical Engineering, 136(6). https://doi.org/10.1115/1.4027411
  2. Girdhar, G., Ubl, S., Jahanbekam, R., Thinamany, S., Belu, A., Wainwright, J., & Wolf, M. F. (2019). Thrombogenicity assessment of Pipeline, Pipeline Shield, Derivo and P64 flow diverters in an in vitro pulsatile flow human blood loop model. eNeurologicalSci, 14, 77–84. https://doi.org/10.1016/j.ensci.2019.01.004
  3. Dmytriw, A. A., Phan, K., Salem, M. M., Adeeb, N., Moore, J. M., Griessenauer, C. J., Foreman, P. M., Shallwani, H., Shakir, H., Siddiqui, A. H., Levy, E. I., Davies, J. M., Harrigan, M. R., Thomas, A. J., & Ogilvy, C. S. (2019). The Pipeline Embolization Device: Changes in Practice and Reduction of Complications in the Treatment of Anterior Circulation Aneurysms in a Multicenter Cohort. Neurosurgery, 86(2), 266–271. https://doi.org/10.1093/neuros/nyz059
  4. King, R. M., Brooks, O. W., Langan, E. T., Caroff, J., Clarençon, F., Tamura, T., Wainwright, J. M., Gounis, M. J., Marosfői, M., & Puri, A. S. (2017). Communicating malapposition of flow diverters assessed with optical coherence tomography correlates with delayed aneurysm occlusion. Journal of NeuroInterventional Surgery, 10(7), 697–702. https://doi.org/10.1136/neurintsurg-2017-013502
  5. Martínez-Galdámez, M., Lamin, S. M., Lagios, K. G., Liebig, T., Ciceri, E. F., Chapot, R., Stockx, L., Chavda, S., Kabbasch, C., Faragò, G., Nordmeyer, H., Boulanger, T., Piano, M., & Boccardi, E. P. (2018). Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up. Journal of NeuroInterventional Surgery, 11(4), 396–399. https://doi.org/10.1136/neurintsurg-2018-014204
  6. Trivelato, F. P., Wajnberg, E., Rezende, M. T. S., Ulhôa, A. C., Piske, R. L., Abud, T. G., de Castro-Afonso, L. H., Abath, C. G. C., Nakiri, G. S., Araújo, J. F. S., Silva, J. L. J., Tosello, R. T., Vanzin, J. R., Manzato, L. B., Baccin, C. E., da Mota, B. A. A., & Abud, D. G. (2019). Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study. Neurosurgery, 87(1), 104–111. https://doi.org/10.1093/neuros/nyz356
  7. Griessenauer, C. J., Goren, O., Dalal, S. S., & Schirmer, C. M. (2018). Pipeline Embolization Device with Shield Technology for Intracranial Aneurysms: An Initial U.S. Experience. World Neurosurgery, 119, 10–14. https://doi.org/10.1016/j.wneu.2018.07.203
  8. L'Allier, P. L., Ducrocq, G., Pranno, N., Noble, S., Ibrahim, R., Grégoire, J. C., Azzari, F., Nozza, A., Berry, C., Doucet, S., Labarthe, B., Théroux, P., & Tardif, J.-C. (2008). Clopidogrel 600-Mg Double Loading Dose Achieves Stronger Platelet Inhibition Than Conventional Regimens. Journal of the American College of Cardiology, 51(11), 1066–1072. https://doi.org/10.1016/j.jacc.2007.12.013
  9. Mascitelli, J. R., Moyle, H., Oermann, E. K., Polykarpou, M. F., Patel, A. A., Doshi, A. H., Gologorsky, Y., Bederson, J. B., & Patel, A. B. (2014). An update to the Raymond–Roy Occlusion Classification of intracranial aneurysms treated with coil embolization. Journal of NeuroInterventional Surgery, 7(7), 496–502. https://doi.org/10.1136/neurintsurg-2014-011258
  10. Maragkos, G. A., Dmytriw, A. A., Salem, M. M., Tutino, V. M., Meng, H., Cognard, C., Machi, P., Krings, T., & Mendes Pereira, V. (2019). Overview of Different Flow Diverters and Flow Dynamics. Neurosurgery, 86(Supplement_1), S21–S34. https://doi.org/10.1093/neuros/nyz323
  11. Hagen, M. W., Girdhar, G., Wainwright, J., & Hinds, M. T. (2016). Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification. Journal of NeuroInterventional Surgery, 9(10), 1006–1011. https://doi.org/10.1136/neurintsurg-2016-012612
  12. Matsuda, Y., Chung, J., & Lopes, D. K. (2017). Analysis of neointima development in flow diverters using optical coherence tomography imaging. Journal of NeuroInterventional Surgery, 10(2), 162–167. https://doi.org/10.1136/neurintsurg-2016-012969
  13. Becske, T., Kallmes, D. F., Saatci, I., McDougall, C. G., Szikora, I., Lanzino, G., Moran, C. J., Woo, H. H., Lopes, D. K., Berez, A. L., Cher, D. J., Siddiqui, A. H., Levy, E. I., Albuquerque, F. C., Fiorella, D. J., Berentei, Z., Marősfoi, M., Cekirge, S. H., & Nelson, P. K. (2013). Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial. Radiology, 267(3), 858–868. https://doi.org/10.1148/radiol.13120099
  14. Kallmes, D. F., Brinjikji, W., Boccardi, E., Ciceri, E., Diaz, O., Tawk, R., Woo, H., Jabbour, P., Albuquerque, F., Chapot, R., Bonafe, A., Dashti, S. R., Delgado Almandoz, J. E., Given II, C., Kelly, M. E., Cross III, D. T., Duckwiler, G., Razack, N., Powers, C. J., … Levy, E. (2016). Aneurysm Study of Pipeline in an Observational Registry (ASPIRe). Interventional Neurology, 5(1-2), 89–99. https://doi.org/10.1159/000446503
  15. Vollherbst, D. F., Cekirge, H. S., Saatci, I., Baltacioglu, F., Onal, B., Koc, O., Rautio, R., Sinisalo, M., Tomasello, A., Vega, P., Martínez-Galdámez, M., Lynch, J., Mendes Pereira, V., Bendszus, M., & Möhlenbruch, M. A. (2022). First clinical multicenter experience with the new Pipeline Vantage flow diverter. Journal of NeuroInterventional Surgery, 15(1), 63–69. https://doi.org/10.1136/neurintsurg-2021-018480
  16. Charbonnier, G., Desilles, J.-P., Escalard, S., Maier, B., Ciccio, G., Smajda, S., Fahed, R., Delvoye, F., Redjem, H., Blanc, R., Piotin, M., & Mazighi, M. (2021). Timing and Spectrum of Neurological Complications After Flow Diverter Implantation for Intracranial Aneurysms. Frontiers in Neurology, 12. https://doi.org/10.3389/fneur.2021.590383
  17. Sailer, A. M. H., Wagemans, B. A. J. M., Nelemans, P. J., de Graaf, R., & van Zwam, W. H. (2014). Diagnosing Intracranial Aneurysms With MR Angiography. Stroke, 45(1), 119–126. https://doi.org/10.1161/strokeaha.113.003133
  18. Traenka, C., Engelter, S. T., Brown, M. M., Dobson, J., Frost, C., & Bonati, L. H. (2019). Silent brain infarcts on diffusion-weighted imaging after carotid revascularisation: A surrogate outcome measure for procedural stroke? A systematic review and meta-analysis. European Stroke Journal, 4(2), 127–143. https://doi.org/10.1177/2396987318824491
  19. Bond, K. M., Brinjikji, W., Murad, M. H., Kallmes, D. F., Cloft, H. J., & Lanzino, G. (2016). Diffusion-Weighted Imaging–Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis. American Journal of Neuroradiology, 38(2), 304–309. https://doi.org/10.3174/ajnr.a4989
  20. Brinjikji, W., Lanzino, G., Cloft, H. J., Siddiqui, A. H., Boccardi, E., Cekirge, S., Fiorella, D., Hanel, R., Jabbour, P., Levy, E., Lopes, D., Lylyk, P., Szikora, I., & Kallmes, D. F. (2016). Risk Factors for Ischemic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the IntrePED Study. American Journal of Neuroradiology, 37(9), 1673–1678. https://doi.org/10.3174/ajnr.a4807
  21. Gory, B., Berge, J., Bonafé, A., Pierot, L., Spelle, L., Piotin, M., Biondi, A., Cognard, C., Mounayer, C., Sourour, N., Barbier, C., Desal, H., Herbreteau, D., Chabert, E., Brunel, H., Ricolfi, F., Anxionnat, R., Decullier, E., Huot, L., … Taschner, C. (2019). Flow Diverters for Intracranial Aneurysms. Stroke, 50(12), 3471–3480. https://doi.org/10.1161/strokeaha.119.024722
  22. Cagnazzo, F., Lefevre, P.-H., Mantilla, D., Rouchaud, A., Morganti, R., Perrini, P., Carlo, D. D., Dargazanli, C., Gascou, G., Riquelme, C., Bonafe, A., & Costalat, V. (2019). Patency of the supraclinoid internal carotid artery branches after flow diversion treatment. A meta-analysis. Journal of Neuroradiology, 46(1), 9–14. https://doi.org/10.1016/j.neurad.2018.07.006
  23. Wang, C.-B., Shi, W.-W., Zhang, G.-X., Lu, H.-C., & Ma, J. (2016). Flow diverter treatment of posterior circulation aneurysms. A meta-analysis. Neuroradiology, 58(4), 391–400. https://doi.org/10.1007/s00234-016-1649-2
  24. Brinjikji, W., Lanzino, G., Cloft, H. J., Siddiqui, A. H., Hanel, R. A., & Kallmes, D. F. (2015). Platelet Testing is Associated with Worse Clinical Outcomes for Patients Treated with the Pipeline Embolization Device. American Journal of Neuroradiology, 36(11), 2090–2095. https://doi.org/10.3174/ajnr.a4411
  25. Saber, H., Kherallah, R. Y., Hadied, M. O., Kazemlou, S., Chamiraju, P., & Narayanan, S. (2018). Antiplatelet therapy and the risk of ischemic and hemorrhagic complications associated with Pipeline embolization of cerebral aneurysms: a systematic review and pooled analysis. Journal of NeuroInterventional Surgery, 11(4), 362–366. https://doi.org/10.1136/neurintsurg-2018-014082

1–25 of 27

Citations

  1. Wenz, F., Wiedemann, T., Rinkel, G. J. E., & Etminan, N. (2026). Flow diverter treatment for saccular unruptured intracranial aneurysms: A systematic review focussing on study quality and initial outcomes. European Stroke Journal, 11(1). https://doi.org/10.1093/esj/23969873251370992
  2. Wang, X., Liu, H., Song, Z., Su, X., Li, X., & Ma, Y. (2025). Comparison of Single Antiplatelet Therapy and Dual Antiplatelet Therapy in the Treatment of Intracranial Aneurysms with Surface-Modified Flow Diverters: A Systematic Review and Meta-Analysis. World Neurosurgery, 203, 124454. https://doi.org/10.1016/j.wneu.2025.124454
  3. Snyder, M. H., & Malek, A. M. (2025). Early angiographic response to Pipeline Vantage flow diverter embolization of intracranial carotid aneurysms. Journal of NeuroInterventional Surgery, 18(7), 1625–1631. https://doi.org/10.1136/jnis-2025-023567
  4. Desai, H., Thind, S., Morsi, R. Z., Kothari, S. A., Karar, L., Chahine, A., Zakaria, J., & Kass-Hout, T. (2025). Flex vs. Vantage Pipeline™ Flow Diverters: Technical analysis in treating complex fusiform basilar artery aneurysm. Interventional Neuroradiology, 31(2), 287–287. https://doi.org/10.1177/15910199241311074
  5. Abu-Fares, O., Adamou, A., Raab, P., Lanfermann, H., Sirakov, A., Middendorff, M., Hounchonou, H. F., Krauss, J. K., & Al-Afif, S. (2025). Safety and efficacy of the pipeline vantage flow diverter for the treatment of saccular aneurysms in the posterior cerebral circulation. The Neuroradiology Journal, 39(3), 315–321. https://doi.org/10.1177/19714009251373070
  6. Wenz, F., Wiedemann, T., Rinkel, G. J., & Etminan, N. (2025). Flow diverter treatment for saccular unruptured intracranial aneurysms: A systematic review focussing on study quality and initial outcomes. European Stroke Journal. https://doi.org/10.1177/23969873251370992
  7. Cortese, J., Ghozy, S., Valizadeh, P., Hasanzadeh, A., Amoukhteh, M., Jannatdoust, P., Hassankhani, A., Ahmadzade, A., Popica, D. A., Kallmes, D. F., & Kadirvel, R. (2025). Initial Experience with the Pipeline Vantage Flow Diverter for Intracranial Aneurysms: A Systematic Review and Meta-Analysis. American Journal of Neuroradiology, 46(3), 510–516. https://doi.org/10.3174/ajnr.a8555
  8. Wadhwa, A., Mensah, E., Young, M., & Ogilvy, C. S. (2024). Variability patterns in dual antiplatelet therapy following endovascular repair of intracranial aneurysms: Insight into regimen heterogeneity and the need for a consensus. Acta Neurochirurgica, 166(1), Article 271. https://doi.org/10.1007/s00701-024-06137-4
  9. Goertz, L., Hohenstatt, S., Zopfs, D., Kottlors, J., Pennig, L., Schlamann, M., Michael, A. E., Liebig, T., A. Möhlenbruch, M., & Kabbasch, C. (2024). Pipeline Vantage Embolization Device for the treatment of intracranial aneurysms: A systematic review and meta-analysis. Interventional Neuroradiology, 32(4), 1680–1690. https://doi.org/10.1177/15910199241264340
  10. Goertz, L., Hohenstatt, S., Vollherbst, D. F., Pflaeging, M., Gronemann, C., Siebert, E., Zopfs, D., Pennig, L., Kottlors, J., Schlamann, M., Bohner, G., Dorn, F., Liebig, T., Möhlenbruch, M., & Kabbasch, C. (2024). Multicenter Experience with the Pipeline Flex and Vantage with Shield Technology for Intracranial Aneurysm Treatment. American Journal of Neuroradiology, 45(10), 1488–1494. https://doi.org/10.3174/ajnr.a8352