Published September 14, 2004 | Journal article | Version v1 | https://doi.org/10.1161/01.cir.0000138391.77285.d9

Magnetic Vascular Port in Minimally Invasive Direct Coronary Artery Bypass Grafting

Description

Background— Minimally invasive direct coronary artery bypass grafting (MIDCAB) is a well-established operative procedure. However, it is technically demanding and is therefore somewhat underused. We evaluated the clinical and angiographic outcome of patients undergoing a MIDCAB procedure with the Ventrica Magnetic Vascular Port (MVP®) system. Methods and Results— A Ventrica MVP® system was used in 10 of 11 selected MIDCAB patients. The system consists of 6 magnetic clips, with 3 clips forming a set. One magnetic clip set is positioned at the arteriotomy of the target artery and of the bypass graft using a preloaded delivery system. These ports then form an anastomosis by magnetic coupling. The mean age of the 10 patients (6 male) was 60.3±11.0 years. Three patients had an angiogram at the time of discharge and 8 returned for a 6-month angiogram. The total procedure time was 128.2±12.2 minutes. The mean anastomotic time was 199 seconds. The mean ischemic time during the anastomosis was 146±146 seconds. There were no in-hospital complications and no device-related adverse events. All 3 predischarge and all 8 6-month angiograms showed patent anastomoses. Conclusions— The magnetic vascular port facilitates the MIDCAB procedure significantly and reduces the ischemic time during the anastomosis. This minimally invasive procedure has the potential to be an alternative to percutaneous transluminal coronary angioplasty and stenting in proximal left anterior descending (LAD) stenosis. It may expand the acceptance of hybrid procedures in which a left internal mammary artery (LIMA)-to-LAD graft optimally supplies the anterior wall and the septum while the circumflex and right coronary artery may be treated interventionally.

Additional details

Dates

Issued
September 14, 2004

References

  1. Nissen, S. E., Tsunoda, T., Tuzcu, E. M., Schoenhagen, P., Cooper, C. J., Yasin, M., Eaton, G. M., Lauer, M. A., Sheldon, W. S., Grines, C. L., Halpern, S., Crowe, T., Blankenship, J. C., & Kerensky, R. (2003). Effect of Recombinant ApoA-I Milano on Coronary Atherosclerosis in Patients With Acute Coronary Syndromes: A Randomized Controlled Trial. JAMA, 290(17), 2292. https://doi.org/10.1001/jama.290.17.2292
  2. Favaloro, R. G. (1969). Saphenous vein graft in the surgical treatment of coronary artery disease. The Journal of Thoracic and Cardiovascular Surgery, 58(2), 178–185. https://doi.org/10.1016/s0022-5223(19)42599-3
  3. https://doi.org/10.1161/circ.77.4.3280159 https://doi.org/10.1161/circ.77.4.3280159
  4. Ascione, R., Lloyd, C. T., Underwood, M. J., Lotto, A. A., Pitsis, A. A., & Angelini, G. D. (1999). Economic outcome of off-pump coronary artery bypass surgery: a prospective randomized study. The Annals of Thoracic Surgery, 68(6), 2237–2242. https://doi.org/10.1016/s0003-4975(99)01123-6
  5. Plomondon, M. E., Cleveland, J. C., Ludwig, S. T., Grunwald, G. K., Kiefe, C. I., Grover, F. L., & Shroyer, A. L. (2001). Off-pump coronary artery bypass is associated with improved risk-adjusted outcomes. The Annals of Thoracic Surgery, 72(1), 114–119. https://doi.org/10.1016/s0003-4975(01)02670-4
  6. Klima, U., Falk, V., Maringka, M., Bargenda, S., Badack, S., Moritz, A., Mohr, F., Haverich, A., & Wimmer-Greinecker, G. (2003). Magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting: A multicenter trial. The Journal of Thoracic and Cardiovascular Surgery, 126(5), 1568–1574. https://doi.org/10.1016/s0022-5223(03)01314-x
  7. Klima, U., Maringka, M., Bagaev, E., Kirschner, S., & Haverich, A. (2004). Total magnetic vascular coupling for arterial revascularization. The Journal of Thoracic and Cardiovascular Surgery, 127(2), 602–603. https://doi.org/10.1016/j.jtcvs.2003.09.050
  8. Noar, J. H., & Evans, R. D. (1999). Rare Earth Magnets in Orthodontics: An Overview. British Journal of Orthodontics, 26(1), 29–37. https://doi.org/10.1093/ortho/26.1.29
  9. Maniglia, A. J., Ko, W. H., Rosenbaum, M., Zhu, W.-L., Werning, J., Belser, R., Drago, P., Falk, T., & Frenz, W. (1994). A Contactless Electromagnetic Implantable Middle Ear Device for Sensorineural Hearing Loss. Ear, Nose & Throat Journal, 73(2), 78–90. https://doi.org/10.1177/014556139407300206
  10. Cope, C., Clark, T. W. I., Ginsberg, G., & Habecker, P. (1999). Stent Placement of Gastroenteric Anastomoses Formed by Magnetic Compression. Journal of Vascular and Interventional Radiology, 10(10), 1379–1386. https://doi.org/10.1016/s1051-0443(99)70248-4
  11. Takao, S., Matsuo, Y., Shinchi, H., Nakajima, S., Aikou, T., Iseji, T., & Yamanouchi, E. (2001). Magnetic Compression Anastomosis for Benign Obstruction of the Common Bile Duct. Endoscopy, 33(11), 988–990. https://doi.org/10.1055/s-2001-17923
  12. Grüneberger, A. D., Hennig, G. R., & Bullemer, F. (1984). A magnet system for urethral closure in females. Journal of Biomedical Engineering, 6(2), 102–106. https://doi.org/10.1016/0141-5425(84)90051-7
  13. Gundry, S. R., Black, K., & Izutani, H. (2000). Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro results. The Journal of Thoracic and Cardiovascular Surgery, 120(3), 473–477. https://doi.org/10.1067/mtc.2000.108596
  14. Martens, S., Dietrich, M., Doss, M., Moritz, A., & Wimmer-Greinecker, G. (2002). The heartflo device for distal coronary anastomoses: clinical experiences in 60 patients. The Annals of Thoracic Surgery, 74(4), 1139–1143. https://doi.org/10.1016/s0003-4975(02)03829-8
  15. Tozzi, P., Solem, J. O., Boumzebra, D., Mucciolo, A., Genton, C. Y., Chaubert, P., & von Segesser, L. K. (2001). Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?. The Annals of Thoracic Surgery, 72(3), S999–S1003. https://doi.org/10.1016/s0003-4975(01)02953-8
  16. Ono, M., Wolf, R. K., Angouras, D., & Schneeberger, E. W. (2002). Early experience of coronary artery bypass grafting with a new self-closing clip device. The Journal of Thoracic and Cardiovascular Surgery, 123(4), 783–787. https://doi.org/10.1067/mtc.2002.120338
  17. Diegeler, A., Thiele, H., Falk, V., Hambrecht, R., Spyrantis, N., Sick, P., Diederich, K. W., Mohr, F. W., & Schuler, G. (2002). Comparison of Stenting with Minimally Invasive Bypass Surgery for Stenosis of the Left Anterior Descending Coronary Artery. New England Journal of Medicine, 347(8), 561–566. https://doi.org/10.1056/nejmoa013563
  18. Farinas, J.-M., Carrier, M., Hébert, Y., Cartier, R., Pellerin, M., Perrault, L. P., & Pelletier, L. C. (1999). Comparison of long-term clinical results of double versus single internal mammary artery bypass grafting. The Annals of Thoracic Surgery, 67(2), 466–470. https://doi.org/10.1016/s0003-4975(98)01196-5
  19. Klima, U., & Haverich, A. (2003). Hybrid Revascularization. In Minimally Invasive Cardiac Surgery (pp. 207–216). Humana Press. https://doi.org/10.1385/1-59259-416-6:207
  20. Wittwer, T., Cremer, J., Boonstra, P., Grandjean, J., Mariani, M., Mügge, A., Drexler, H., den Heijer, P., Leitner, E.-R. v ., Hepp, A., Wehr, M., & Haverich, A. (2000). Myocardial "hybrid" revascularisation with minimally invasive direct coronary artery bypass grafting combined with coronary angioplasty: preliminary results of a multicentre study. Heart, 83(1), 58–63. https://doi.org/10.1136/heart.83.1.58
  21. Filsoufi, F., Farivar, R. S., Aklog, L., Anderson, C. A., Chen, R. H., Lichtenstein, S., Zhang, J., & Adams, D. H. (2004). Automated distal coronary bypass with a novel magnetic coupler (MVP system). The Journal of Thoracic and Cardiovascular Surgery, 127(1), 185–192. https://doi.org/10.1016/j.jtcvs.2003.04.005
  22. Limet, R., & David, J. L. (1999). Antiplatelet Activity of Clopidogrel in Coronary Artery Bypass Graft Surgery Patients. Thrombosis and Haemostasis, 82(11), 1417–1421. https://doi.org/10.1055/s-0037-1614847
  23. Dol, F., Bernat, A., Falotico, R., Lalé, A., Savi, P., & Herbert, J.-M. (1998). The Antiaggregating and Antithrombotic Activity of Clopidogrel Is Potentiated by Aspirin in Several Experimental Models in the Rabbit. Thrombosis and Haemostasis, 80(09), 512–518. https://doi.org/10.1055/s-0037-1615238

Citations

  1. https://doi.org/10.1186/s12938-026-01526-5
  2. Guo, H.-B., Wang, M.-F., Yin, R.-Q., & Zhi, K.-K. (2025). A novel arterial coupler with non-return snap-fit connection approach optimized arterial end-to-end anastomotic technique: An experimental study. Chinese Journal of Traumatology, 28(1), 13–21. https://doi.org/10.1016/j.cjtee.2024.09.006
  3. Song, J.-. shu ., Wang, F.-. min ., Zhang, J.-. wen ., & Zhang, X.-. feng . (2025). Magnetic compression anastomosis in vascular surgery: a comprehensive review of techniques and clinical applications. Magnetic Medicine, 1(2), 100023. https://doi.org/10.1016/j.magmed.2025.100023
  4. Liu, G., Zhang, C., Zhang, J., Wu, Y., & Ouyang, B. (2025). NdFeB-YOLOv10: an intelligent detection network for sintered NdFeB raw defects. Measurement Science and Technology, 36(3), 035111. https://doi.org/10.1088/1361-6501/adb0e3
  5. Zhang, M., Zhao, X., Mao, J., Shi, A., Lyu, X., Lyu, Y., & Yan, X. (2024). Comparative study on the establishment efficacy of four types of animal models of rectovaginal fistula in rabbits. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-63128-2
  6. https://doi.org/10.3748/wjg.v30.i16.2272
  7. https://doi.org/10.3748/wjg.v30.i6.599
  8. https://doi.org/10.4240/wjgs.v16.i5.1443
  9. Lu, Q., Liu, K., Shi, A.-H., Zhang, W., Wan, Y., Wu, R.-Q., Lv, Y., & Wang, S.-P. (2023). Liver transplantation using magnetic anastomosis in pigs. Scientific Reports, 13(1). https://doi.org/10.1038/s41598-023-44306-0
  10. https://doi.org/10.3389/fsurg.2023.1253728
  11. Zhou, X., Liang, D., Li, Q., Zhao, L., Bin, Y., Ma, F., Wu, R., Lv, Y., & Li, Q. (2023). The sealing effect of magnetic-sealing uterine manipulator in isolated uterus from patients with early-stage cervical cancer: a pre-clinical study. Journal of Gynecologic Oncology, 34(6). https://doi.org/10.3802/jgo.2023.34.e78
  12. Bai, J., Zhang, M., Shi, A., Lin, Y., Guo, K., Geng, Z., Zhang, D., Ma, F., Lyu, Y., & Yan, X. (2022). Magnetic anchor technique in laparoscopic cholecystectomy: a single-center, prospective, randomized controlled trial. Surgical Endoscopy, 37(2), 1005–1012. https://doi.org/10.1007/s00464-022-09562-7
  13. Feng, Z., Wang, S.-P., Wang, H.-H., Lu, Q., Qiao, W., Wang, K.-L., Ding, H.-F., Wang, Y., Wang, R.-F., Shi, A.-H., Ren, B.-Y., Jiang, Y.-N., He, B., Yu, J.-W., Wu, R.-Q., & Lv, Y. (2022). Magnetic-assisted laparoscopic liver transplantation in swine. Hepatobiliary & Pancreatic Diseases International, 21(4), 340–346. https://doi.org/10.1016/j.hbpd.2021.12.008
  14. Zhang, M., Shi, A., Liu, P., Ye, D., Zhang, H., Mou, X., Xu, S., Zhang, Z., Lyu, Y., & Yan, X. (2022). Magnetic Compression Technique for Esophageal Anastomosis in Rats. Journal of Surgical Research, 276, 283–290. https://doi.org/10.1016/j.jss.2022.03.001
  15. Wang, H.-H., Ma, J., Wang, S.-P., Ma, F., Lu, J.-W., Xu, X.-H., Lv, Y., & Yan, X.-P. (2019). Magnetic Anastomosis Rings to Create Portacaval Shunt in a Canine Model of Portal Hypertension. Journal of Gastrointestinal Surgery, 23(11), 2184–2192. https://doi.org/10.1007/s11605-018-3888-5
  16. https://doi.org/10.3748/wjg.v25.i30.4213
  17. Bai, J., Huo, X., Ma, J., Lv, Y., & Yan, X. (2018). Magnetic compression technique for colonic anastomosis in rats. Journal of Surgical Research, 231, 24–29. https://doi.org/10.1016/j.jss.2018.05.006
  18. Cremer, J. T., Schöttler, J., & Hoffmann, G. (2017). Coronary Artery Disease. In Cardiac Surgery (pp. 721–742). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-662-52672-9_22
  19. https://doi.org/10.1177/0267659115618004
  20. Fan, C., Yan, X.-P., Liu, S.-Q., Wang, C.-B., Li, J.-H., Yu, L., Wu, Z., & Lv, Y. (2012). Roux-en-Y choledochojejunostomy using novel magnetic compressive anastomats in canine model of obstructive jaundice. Hepatobiliary & Pancreatic Diseases International, 11(1), 81–88. https://doi.org/10.1016/s1499-3872(11)60129-x
  21. https://doi.org/10.53347/rid-14867
  22. Cremer, J., & Schöttler, J. (2010). Koronare Herzkrankheit (KHK). In Herzchirurgie (pp. 569–588). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-540-79713-5_20
  23. Wang, Z., Brown, A. W., Brown, S. I., Wang, L., Andre, P., Florence, G. J., & Cuschieri, A. (2010). Intra-luminal injection of ferro-fluid for magnetic bowel retraction in minimal access surgery. Proceedings of 2010 IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications, 168–173. https://doi.org/10.1109/mesa.2010.5552080
  24. Suyker, W. J. L., & Borst, C. (2008). Coronary Connector Devices: Analysis of 1,469 Anastomoses in 1,216 Patients. The Annals of Thoracic Surgery, 85(5), 1828–1836. https://doi.org/10.1016/j.athoracsur.2008.01.015
  25. https://doi.org/10.1177/021849230701500106

1–25 of 27