Fracture Resistance of Repaired 5Y-PSZ Zirconia Crowns after Endodontic Access
Description
This study analyzed the fracture load before and after a chewing simulation of zirconia crowns that were trepanned and repaired using composite resin. Overall, 3 groups with 15 5Y-PSZ crowns in each group were tested. For group A, the fracture load of the unmodified crowns was evaluated. For group B, the crowns were trepanned and repaired using composite resin, also followed by a fracture test. For group C, crowns were prepared like in group B but received thermomechanical cycling before the final fracture tests. Furthermore, scanning electron microscopy (SEM) and X-ray microscopy (XRM) analysis were performed for group C. The mean fracture loads and standard deviation were 2260 N ± 410 N (group A), 1720 N ± 380 N (group B), and 1540 N ± 280 N (group C). Tukey-Kramer multiple comparisons showed a significant difference between groups A and B (p < 0.01) and groups A and C (p < 0.01). After ageing, surface fissures were detected via SEM, but no cracks that reached from the occlusal to the inner side of the crown were detected via XRM. Within the limitations of this study, it can be stated that trepanned and composite-repaired 5Y-PSZ crowns show lower fracture loads than 5Y-PSZ crowns without trepanation.
Additional details
Identifiers
- OpenAlex
- W4323565165
- PMID
- 36975573
- URL
- https://www.mdpi.com/2304-6767/11/3/76
Funding
- DFG
- 316923185
Dates
- Issued
-
March 7, 2023
References
- Denry, I., & Kelly, J. R. (2008). State of the art of zirconia for dental applications. Dental Materials, 24(3), 299–307. https://doi.org/10.1016/j.dental.2007.05.007
- Kelly, P. M., & Francis Rose, L. R. (2002). The martensitic transformation in ceramics — its role in transformation toughening. Progress in Materials Science, 47(5), 463–557. https://doi.org/10.1016/s0079-6425(00)00005-0
- Miyazaki, T., Nakamura, T., Matsumura, H., Ban, S., & Kobayashi, T. (2013). Current status of zirconia restoration. Journal of Prosthodontic Research, 57(4), 236–261. https://doi.org/10.1016/j.jpor.2013.09.001
- Three generations of zirconia: From veneered to monolithic. Part I
- Worpenberg, C., Stiesch, M., Eisenburger, M., Breidenstein, B., Busemann, S., & Greuling, A. (2023). The effect of surface treatments on the adhesive bond in all-ceramic dental crowns using four-point bending and dynamic loading tests. Journal of the Mechanical Behavior of Biomedical Materials, 139, Article 105686. https://doi.org/10.1016/j.jmbbm.2023.105686
- Swain, M. V. (2009). Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomaterialia, 5(5), 1668–1677. https://doi.org/10.1016/j.actbio.2008.12.016
- Schmitter, M., Mueller, D., & Rues, S. (2012). Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer. Journal of Dentistry, 40(2), 154–162. https://doi.org/10.1016/j.jdent.2011.12.007
- Zhang, Y., & Lawn, B. R. (2017). Novel Zirconia Materials in Dentistry. Journal of Dental Research, 97(2), 140–147. https://doi.org/10.1177/0022034517737483
- Lynch, C. D., Hale, R., Chestnutt, I. G., & Wilson, N. H. F. (2018). Reasons for placement and replacement of crowns in general dental practice. British Dental Journal, 225(3), 229–234. https://doi.org/10.1038/sj.bdj.2018.541
- A Cross-Sectional Survey on Reasons for Initial Placement and Replacement of Single Crowns
- Wiegand, A., & Kanzow, P. (2020). Effect of Repairing Endodontic Access Cavities on Survival of Single Crowns and Retainer Restorations. Journal of Endodontics, 46(3), 376–382. https://doi.org/10.1016/j.joen.2019.11.012
- Blatz, M. B., Sadan, A., Martin, J., & Lang, B. (2004). In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling. The Journal of Prosthetic Dentistry, 91(4), 356–362. https://doi.org/10.1016/j.prosdent.2004.02.001
- Kern, M., & Wegner, S. M. (1998). Bonding to zirconia ceramic: adhesion methods and their durability. Dental Materials, 14(1), 64–71. https://doi.org/10.1016/s0109-5641(98)00011-6
- Effect of different artificial aging conditions on ceramic-composite bond strength
- Wolfart, M., Lehmann, F., Wolfart, S., & Kern, M. (2007). Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods. Dental Materials, 23(1), 45–50. https://doi.org/10.1016/j.dental.2005.11.040
- Cristoforides, P., Amaral, R., May, L. G., Bottino, M. A., & Valandro, L. F. (2012). Composite Resin to Yttria Stabilized Tetragonal Zirconia Polycrystal Bonding: Comparison of Repair Methods. Operative Dentistry, 37(3), 263–271. https://doi.org/10.2341/11-193-l
- Oyagüe, R. C., Monticelli, F., Toledano, M., Osorio, E., Ferrari, M., & Osorio, R. (2009). Effect of water aging on microtensile bond strength of dual-cured resin cements to pre-treated sintered zirconium-oxide ceramics. Dental Materials, 25(3), 392–399. https://doi.org/10.1016/j.dental.2008.09.002
- Xible, A. A., de Jesus Tavarez, R. R., de Araujo, C. dos R. P., & Bonachela, W. C. (2006). Effect of silica coating and silanization on flexural and composite-resin bond strengths of zirconia posts: An in vitro study. The Journal of Prosthetic Dentistry, 95(3), 224–229. https://doi.org/10.1016/j.prosdent.2005.12.010
- Inokoshi, M., Poitevin, A., De Munck, J., Minakuchi, S., & Van Meerbeek, B. (2013). Bonding effectiveness to different chemically pre-treated dental zirconia. Clinical Oral Investigations, 18(7), 1803–1812. https://doi.org/10.1007/s00784-013-1152-7
- Begand, S., Spintzyk, S., Geis-Gerstorfer, J., Bourauel, C., Keilig, L., Lohbauer, U., Worpenberg, C., Greuling, A., Adjiski, R., Jandt, K. D., Lümkemann, N., Stawarczyk, B., Güllmar, A., Kailer, A., Oberle, N., & Stephan, M. (2022). Fracture toughness of 3Y-TZP ceramic measured by the Chevron-Notch Beam method: A round-robin study. Dental Materials, 38(7), 1128–1139. https://doi.org/10.1016/j.dental.2022.05.001
- Heydecke, G., Butz, F., Hussein, A., & Strub, J. R. (2002). Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and-core systems. The Journal of Prosthetic Dentistry, 87(4), 438–445. https://doi.org/10.1067/mpr.2002.123849
- Beschnidt, S. M., & Strub, J. R. (1999). Evaluation of the marginal accuracy of different all‐ceramic crown systems after simulation in the artificial mouth. Journal of Oral Rehabilitation, 26(7), 582–593. https://doi.org/10.1046/j.1365-2842.1999.00449.x
- Greuling, A., Matthies, A., & Eisenburger, M. (2023). Fracture load of 4-unit interim fixed partial dentures using 3D-printed and traditionally manufactured materials. The Journal of Prosthetic Dentistry, 129(4), 607.e1–607.e8. https://doi.org/10.1016/j.prosdent.2022.12.013
- Fracture strength of 5 different all-ceramic crown systems
- Marginal discrepancies and leakage of all-ceramic crowns: Influence of luting agents and aging conditions
1–25 of 40
Citations
- Wu, Z., Wei, C., Chen, X., Li, M., Zhu, J., & Huang, C. (2026). Influence of endodontic access on the fracture resistance, retention and microleakage of full-coverage restorations in vitro: A systematic review and meta-analysis. Journal of Dentistry, 175, 106941. https://doi.org/10.1016/j.jdent.2026.106941
- Gamal, A., Aldamaty, M. F., Mohamed, H. R., & Othman, H. I. (2025). Impact of endodontic access cavity preparation on the fracture resistance of CAD-CAM crowns. BMC Oral Health, 25(1). https://doi.org/10.1186/s12903-025-05934-2
- Almalki, A. (2025). The influence of endodontic access preparation on the mechanical strength of zirconia crowns: A literature review. Saudi Endodontic Journal, 16(1), 20–26. https://doi.org/10.4103/sej.sej_109_25
- Vasyliv, B. D. (2024). Application of Various Reduction Techniques for the Improvement of Microstructure and Strength of YSZ–NiO(Ni) Solid Oxide Fuel Cell Anodes. In Springer Proceedings in Physics (pp. 333–347). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-67519-5_23
- Vasyliv, B. D. (2024). The Effect of Hydrogen Concentration on the High-Temperature (600 °C) Reduction Performance and Strength of YSZ–NiO(Ni) Anode Material for Solid Oxide Fuel Cells. In Springer Proceedings in Physics (pp. 367–381). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-67519-5_25
- Soares, P. M., da Rosa, L. S., Pilecco, R. O., Dal Piva, A. M. de O., Tribst, J. P. M., Werner, A., Valandro, L. F., Pereira, G. K. R., Kleverlaan, C. J., & Rippe, M. P. (2024). Repair of monolithic zirconia restorations with different direct resin composites: effect on the fatigue bonding and mechanical performance. Clinical Oral Investigations, 28(2), Article 149. https://doi.org/10.1007/s00784-024-05542-4
- Islam, E. A., Oumayma, M., Imen, K., Ilhem, B. O., Zohra, N., Dalenda, H., & Belhassan, H. (2024). Esthetic rehabilitation of dental fluorosis with CAD-CAM generated yttria-stabilized zirconia and glass-ceramic laminate veneers. Journal of Dental Health, Oral Disorders & Therapy, 15(1), 11–16. https://doi.org/10.15406/jdhodt.2024.15.00609
- Guerreiro Viegas, O., & Santos, J. M. M. (2024). Selective root canal retreatment of a maxillary first molar: a case report with a 9-year follow up. Frontiers in Dental Medicine, 5. https://doi.org/10.3389/fdmed.2024.1422390
- da Rosa, L. S., Pilecco, R. O., Soares, P. M., Rippe, M. P., Pereira, G. K. R., Valandro, L. F., Kleverlaan, C. J., Feilzer, A. J., & Tribst, J. P. M. (2024). Repair protocols for indirect monolithic restorations: a literature review. PeerJ, 12, e16942. https://doi.org/10.7717/peerj.16942
- Soares, P. M., da Rosa, L. S., Pereira, G. K. R., Valandro, L. F., Rippe, M. P., Dal Piva, A. M. de O., Feilzer, A. J., Kleverlaan, C. J., & Tribst, J. P. M. (2023). Mechanical Behavior of Repaired Monolithic Crowns: A 3D Finite Element Analysis. Dentistry Journal, 11(11), 254. https://doi.org/10.3390/dj11110254