Published 2011 | Book chapter | Version v1 | https://doi.org/10.1533/9780857091413.3.403

Magnesium (Mg) corrosion: a challenging concept for degradable implants

Additional details

Dates

Issued
2011

References

  1. B. Müller, C. V. L. S. F. I. of T. C.-. 8092 Z. S., Bernhardt, R., Scharnweber, D., Müller, B., Thurner, P., Schliephake, H., Wyss, P., Beckmann, F., Goebbels, J., & Worch, H. (2004). Comparison of Microfocus- and Synchrotron X-ray Tomography for the Analysis of Osteointegration around Ti6Al4V Implants. European Cells and Materials, 7, 42–51. https://doi.org/10.22203/ecm.v007a05
  2. Bernhardt, R., van den Dolder, J., Bierbaum, S., Beutner, R., Scharnweber, D., Jansen, J., Beckmann, F., & Worch, H. (2005). Osteoconductive modifications of Ti-implants in a goat defect model: characterization of bone growth with SR μCT and histology. Biomaterials, 26(16), 3009–3019. https://doi.org/10.1016/j.biomaterials.2004.08.030
  3. Bobacka, J., Ivaska, A., & Lewenstam, A. (2008). Potentiometric Ion Sensors. Chemical Reviews, 108(2), 329–351. https://doi.org/10.1021/cr068100w
  4. Bohner, M., & Lemaitre, J. (2009). Can bioactivity be tested in vitro with SBF solution?. Biomaterials, 30(12), 2175–2179. https://doi.org/10.1016/j.biomaterials.2009.01.008
  5. Bonse, U., & Busch, F. (1996). X-ray computed microtomography (μCT) using synchrotron radiation (SR). Progress in Biophysics and Molecular Biology, 65(1-2), 133–169. https://doi.org/10.1016/s0079-6107(96)00011-9
  6. Bonse, U., Busch, F., Günnewig, O., Beckmann, F., Pahl, R., Delling, G., Hahn, M., & Graeff, W. (1994). 3D computed X-ray tomography of human cancellous bone at 8 μm spatial and 10−4 energy resolution. Bone and Mineral, 25(1), 25–38. https://doi.org/10.1016/s0169-6009(08)80205-x
  7. DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., ILSLEY, C., & ERBEL, R. (2004). Drug‐Eluting Bioabsorbable Magnesium Stent. Journal of Interventional Cardiology, 17(6), 391–395. https://doi.org/10.1111/j.1540-8183.2004.04081.x
  8. Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., Ilsley, C., Böse, D., Koolen, J., Lüscher, T. F., Weissman, N., & Waksman, R. (2007). Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. The Lancet, 369(9576), 1869–1875. https://doi.org/10.1016/s0140-6736(07)60853-8
  9. Feyerabend, F., Witte, F., Kammal, M., & Willumeit, R. (2006). Unphysiologically High Magnesium Concentrations Support Chondrocyte Proliferation and Redifferentiation. Tissue Engineering, 12(12), 3545–3556. https://doi.org/10.1089/ten.2006.12.3545
  10. Günzel, D., & Schlue, W.-R. (2002). Determination of [Mg2+]i – an update on the use of Mg2+-selective electrodes. Biometals, 15(3), 237–249. https://doi.org/10.1023/a:1016074714951
  11. Hort, N., Huang, Y., Fechner, D., Störmer, M., Blawert, C., Witte, F., Vogt, C., Drücker, H., Willumeit, R., & Kainer, K. U. (2010). Magnesium alloys as implant materials – Principles of property design for Mg–RE alloys☆. Acta Biomaterialia, 6(5), 1714–1725. https://doi.org/10.1016/j.actbio.2009.09.010
  12. Magnesium alloys for the design of medical implants
  13. The effects of magnesium particles in posterolateral spinal fusion: an experimental in vivo study in a sheep model
  14. Kokubo, T., Ito, S., Shigematsu, M., Sanka, S., & Yamamuro, T. (1987). Fatigue and life-time of bioactive glass-ceramic A-W containing apatite and wollastonite. Journal of Materials Science, 22(11), 4067–4070. https://doi.org/10.1007/bf01133359
  15. Kray, R. H. (1934). Modified Hydrogen Evolution Method for Metallic Magnesium, Aluminum, and Zinc. Industrial & Engineering Chemistry Analytical Edition, 6(4), 250–251. https://doi.org/10.1021/ac50090a007
  16. Diffusion coefficients and solubility coefficients for gases in biological fluids and tissues: a review
  17. Liu, C., Xin, Y., Tian, X., & Chu, P. K. (2007). Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin. Journal of Materials Research, 22(7), 1806–1814. https://doi.org/10.1557/jmr.2007.0241
  18. LORKING, K. F. (1964). Inhibition of Corrosion of Magnesium in Chromic Acid. Nature, 201(4914), 75–75. https://doi.org/10.1038/201075a0
  19. Editorial to Special Issue on Biodegradable Metals
  20. Mueller, W., Fernández Lorenzo de Mele, M., Nascimento, M. L., & Zeddies, M. (2008). Degradation of magnesium and its alloys: Dependence on the composition of the synthetic biological media. Journal of Biomedical Materials Research Part A, 90A(2), 487–495. https://doi.org/10.1002/jbm.a.32106
  21. Oyane, A., Kim, H., Furuya, T., Kokubo, T., Miyazaki, T., & Nakamura, T. (2003). Preparation and assessment of revised simulated body fluids. Journal of Biomedical Materials Research Part A, 65A(2), 188–195. https://doi.org/10.1002/jbm.a.10482
  22. Piiper, J., Canfield, R. E., & Rahn, H. (1962). Absorption of various inert gases from subcutaneous gas pockets in rats. Journal of Applied Physiology, 17(2), 268–274. https://doi.org/10.1152/jappl.1962.17.2.268
  23. Rettig, R., & Virtanen, S. (2008). Composition of corrosion layers on a magnesium rare‐earth alloy in simulated body fluids. Journal of Biomedical Materials Research Part A, 88A(2), 359–369. https://doi.org/10.1002/jbm.a.31887
  24. Corrosion resistance of magnesium alloys
  25. Song, G. L., & Atrens, A. (1999). Corrosion Mechanisms of Magnesium Alloys. Advanced Engineering Materials, 1(1), 11–33. https://doi.org/10.1002/(sici)1527-2648(199909)1:1%3C11::aid-adem11%3E3.0.co;2-n

1–25 of 44

Citations

  1. Singh, G., Singh, S., & Sidhu, S. S. (2026). Corrosion protection of magnesium alloys by electrophoretic deposition: Recent developments and future perspectives. Surface Engineering. https://doi.org/10.1177/02670844251412599
  2. Khlusov, I. A., Prosolov, K. A., Sharkeev, Y. P., Gorokhova, A. V., & Volinsky, A. A. (2025). A Review of Magnesium Alloys In Vivo Antibacterial Properties: Challenges, Solutions, and Perspectives in Implant‐Associated Orthopedic Infections. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 113(7). https://doi.org/10.1002/jbm.b.35602
  3. Valiev, R. Z., Zheng, Y., & Edalati, K. (2024). Review: nanoSPD-produced metallic materials for advanced medical devices. Journal of Materials Science, 59(14), 5681–5697. https://doi.org/10.1007/s10853-024-09464-0
  4. Garimella, A., Rathi, D., Jangid, R., Khare, D., Dubey, A. K., Ghosh, S. B., & Bandyopadhyay-Ghosh, S. (2024). Biopolymer-coated magnesium-alloy-based multi-functional bio-nanocomposite scaffolds. Materials Technology, 39(1). https://doi.org/10.1080/10667857.2024.2390291
  5. Li, H., Wen, J., Gong, Y., He, J., & Feng, W. (2023). Enhancement of corrosion resistance and mechanical properties of Mg–2.0Zn–0.5Zr–1.5Dy (mass%) alloy in a corrosive medium by a microarc oxidation/polylactic acid composite coating. Materials and Corrosion, 74(10), 1456–1470. https://doi.org/10.1002/maco.202313886
  6. Garimella, A., M, R., Ghosh, S. B., Bandyopadhyay‐Ghosh, S., & Agrawal, A. K. (2022). Bioactive fluorcanasite reinforced magnesium alloy‐based porous bio‐nanocomposite scaffolds with tunable mechanical properties. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 111(2), 463–477. https://doi.org/10.1002/jbm.b.35166
  7. Badisha, V., Rajulapati, S. K., & Buradagunta, R. S. (2022). Developing Mg Based Composites for Degradable Orthopedic Implant Applications: A Review. Advances in Science and Technology, 120, 61–67. https://doi.org/10.4028/p-y3p82n
  8. Tan, J., & Ramakrishna, S. (2021). Applications of Magnesium and Its Alloys: A Review. Applied Sciences, 11(15), 6861. https://doi.org/10.3390/app11156861
  9. Negrescu, A.-M., Necula, M.-G., Gebaur, A., Golgovici, F., Nica, C., Curti, F., Iovu, H., Costache, M., & Cimpean, A. (2021). In Vitro Macrophage Immunomodulation by Poly(ε-caprolactone) Based-Coated AZ31 Mg Alloy. International Journal of Molecular Sciences, 22(2), 909. https://doi.org/10.3390/ijms22020909
  10. Li, H., Wen, J., Liu, Y., He, J., Shi, H., & Tian, P. (2020). Progress in Research on Biodegradable Magnesium Alloys: A Review. Advanced Engineering Materials, 22(7). https://doi.org/10.1002/adem.202000213
  11. Su, Y., Wang, Y., Tang, L., Zheng, Y., Qin, Y.-X., & Zhu, D. (2017). Development of Biodegradable Zn-Based Medical Implants. In Orthopedic Biomaterials (pp. 311–329). Springer International Publishing. https://doi.org/10.1007/978-3-319-73664-8_12
  12. Bowen, P. K., Drelich, J., & Goldman, J. (2013). Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents. Advanced Materials, 25(18), 2577–2582. https://doi.org/10.1002/adma.201300226
  13. Bowen, P. K., Drelich, J., Buxbaum, R. E., Rajachar, R. M., & Goldman, J. (2012). New approaches in evaluating metallic candidates for bioabsorbable stents. Emerging Materials Research, 1(5), 237–255. https://doi.org/10.1680/emr.12.00017