Published December 22, 2022 | Preprint | Version v1 | https://doi.org/10.1101/2022.12.21.22283800

Repeatability of Pulse Oximetry Measurements in Children During Triage in Two Ugandan Hospitals

Description

ABSTRACT Background In low- and middle-income countries, health workers use pulse oximeters for intermittent spot measurements of SpO 2 . However, the accuracy and reliability when used for spot measurements has not been determined. We evaluated the repeatability of spot measurements, and the ideal observation time of measurement to guide recommendations during spot check measurements. Methods Two one-minute measurements were done for the 3,903 subjects enrolled in the study, collecting 1Hz SpO 2 and signal quality index (SQI) data. The repeatability between the two measurements was assessed using an intraclass correlation coefficient (ICC), calculated using a median of all seconds of non-zero SpO 2 values for each recording (any quality, Q1), and again with a quality filter only using seconds with SQI ≥ 90% (good quality, Q2). The ICC was also calculated for both these conditions using subsets of the minute, in increasing increments of 5 seconds, up to the whole minute. Lastly, the whole minute ICC was calculated with good quality (Q2), including only records where both measurements had a mean SQI > 70% (Q3). Findings The repeatability ICC with condition Q1 was 0.591 (95% confidence interval (CI) = 0.570, 0.611). Using only the first 5 seconds of each measurement reduced the repeatability to 0.200 (95% CI = 0.169, 0.230). Filtering with Q2, the whole minute ICC was 0.855 (95% CI = 0.847, 0.864). The ICC did not improve beyond the first 35 seconds. For Q3, the repeatability rose to 0.908 (95% CI = 0.901, 0.914). Conclusions Training guidelines must emphasize the importance of signal quality and duration of measurement, targeting a minimum of 35 seconds of adequate-quality, stable data. In addition, the design of new devices should incorporate user prompts and force quality checks to encourage more accurate pulse oximetry measurement. Trial Registration Clinical Trials.gov Identifier: NCT04304235 , Registered 11 March 2020.

Additional details

Dates

Issued
December 22, 2022

References

  1. World Health Organization. Paediatric Emergency Triage, Assessment and Treatment UPDATED GUIDELINE.; 2016. Accessed November 22, 2022. https://apps.who.int/iris/handle/10665/204463
  2. Oxygen is an essential medicine: a call for international action
  3. Raihana, S., Dunsmuir, D., Huda, T., Zhou, G., Rahman, Q. S.-. ur ., Garde, A., Moinuddin, M., Karlen, W., Dumont, G. A., Kissoon, N., El Arifeen, S., Larson, C., & Ansermino, J. M. (2016). Correction: Development and Internal Validation of a Predictive Model Including Pulse Oximetry for Hospitalization of Under-Five Children in Bangladesh. PLOS ONE, 11(1), e0147560. https://doi.org/10.1371/journal.pone.0147560
  4. Mawji, A., Akech, S., Mwaniki, P., Dunsmuir, D., Bone, J., Wiens, M. O., Görges, M., Kimutai, D., Kissoon, N., English, M., & Ansermino, M. J. (2021). Derivation and internal validation of a data-driven prediction model to guide frontline health workers in triaging children under-five in Nairobi, Kenya. Wellcome Open Research, 4, 121. https://doi.org/10.12688/wellcomeopenres.15387.3
  5. Reed, C., Madhi, S. A., Klugman, K. P., Kuwanda, L., Ortiz, J. R., Finelli, L., Fry, A. M., & Jhaveri, R. (2012). Development of the Respiratory Index of Severity in Children (RISC) Score among Young Children with Respiratory Infections in South Africa. PLoS ONE, 7(1), e27793. https://doi.org/10.1371/journal.pone.0027793
  6. Herbert, L. J., & Wilson, I. H. (2012). Pulse oximetry in low-resource settings. Breathe, 9(2), 90–98. https://doi.org/10.1183/20734735.038612
  7. Baker, K., Akasiima, M., Wharton-Smith, A., Habte, T., Matata, L., Nanyumba, D., Okwir, M., Sebsibe, A., Marasciulo, M., Petzold, M., & Källander, K. (2018). Performance, Acceptability, and Usability of Respiratory Rate Timers and Pulse Oximeters When Used by Frontline Health Workers to Detect Symptoms of Pneumonia in Sub-Saharan Africa and Southeast Asia: Protocol for a Two-Phase, Multisite, Mixed-Methods Trial. JMIR Research Protocols, 7(10), e10191. https://doi.org/10.2196/10191
  8. Duke, T., Subhi, R., Peel, D., & Frey, B. (2009). Pulse oximetry: technology to reduce child mortality in developing countries. Annals of Tropical Paediatrics, 29(3), 165–175. https://doi.org/10.1179/027249309x12467994190011
  9. Karlen, W., Petersen, C. L., Dumont, G. A., & Ansermino, J. M. (2015). Variability in estimating shunt from single pulse oximetry measurements. Physiological Measurement, 36(5), 967–981. https://doi.org/10.1088/0967-3334/36/5/967
  10. Harper, D. G. C. (1994). Some comments on the repeatability of measurements. Ringing & Migration, 15(2), 84–90. https://doi.org/10.1080/03078698.1994.9674078
  11. Mawji, A., Li, E., Komugisha, C., Akech, S., Dunsmuir, D., Wiens, M. O., Kissoon, N., Kenya-Mugisha, N., Tagoola, A., Kimutai, D., Bone, J. N., Dumont, G., & Ansermino, J. M. (2020). Smart triage: triage and management of sepsis in children using the point-of-care Pediatric Rapid Sepsis Trigger (PRST) tool. BMC Health Services Research, 20(1). https://doi.org/10.1186/s12913-020-05344-w
  12. Mawji, A., Li, E., Dunsmuir, D., Komugisha, C., Novakowski, S. K., Wiens, M. O., Vesuvius, T. A., Kissoon, N., & Ansermino, J. M. (2022). Smart triage: Development of a rapid pediatric triage algorithm for use in low-and-middle income countries. Frontiers in Pediatrics, 10. https://doi.org/10.3389/fped.2022.976870
  13. Mawji, A., Li, E., Chandna, A., Kortz, T., Akech, S., Wiens, M. O., Kissoon, N., Ansermino, M., & Pittet, V. (2021). Common data elements for predictors of pediatric sepsis: A framework to standardize data collection. PLOS ONE, 16(6), e0253051. https://doi.org/10.1371/journal.pone.0253051
  14. Dunsmuir D , Petersen C , Karen W , Lim J , Dumont G , Ansermino JM . THE PHONE OXIMETER FOR MOBILE SPOT-CHECK. 2012.
  15. ISO 5725-1:1994. ISO. https://www.iso.org/standard/11833.html. Published April 14, 2022. Accessed November 23, 2022.
  16. The R project for statistical computing. R. https://www.r-project.org/. Accessed November 23, 2022.
  17. Jubran, A. (2015). Pulse oximetry. Critical Care, 19(1). https://doi.org/10.1186/s13054-015-0984-8
  18. Mitgang, E. A., Blaya, J. A., & Chopra, M. (2021). Digital Health in Response to COVID‐19 in Low‐ and Middle‐income Countries: Opportunities and Challenges. Global Policy, 12(S6), 107–109. https://doi.org/10.1111/1758-5899.12880
  19. Silenou, B. C., Nyirenda, J. L. Z., Zaghloul, A., Lange, B., Doerrbecker, J., Schenkel, K., & Krause, G. (2021). Availability and Suitability of Digital Health Tools in Africa for Pandemic Control: Scoping Review and Cluster Analysis. JMIR Public Health and Surveillance, 7(12), e30106. https://doi.org/10.2196/30106
  20. Budd, J., Miller, B. S., Manning, E. M., Lampos, V., Zhuang, M., Edelstein, M., Rees, G., Emery, V. C., Stevens, M. M., Keegan, N., Short, M. J., Pillay, D., Manley, E., Cox, I. J., Heymann, D., Johnson, A. M., & McKendry, R. A. (2020). Digital technologies in the public-health response to COVID-19. Nature Medicine, 26(8), 1183–1192. https://doi.org/10.1038/s41591-020-1011-4
  21. Tuti, T., Aluvaala, J., Akech, S., Agweyu, A., Irimu, G., & English, M. (2021). Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study. BMJ Open, 11(9), e050995. https://doi.org/10.1136/bmjopen-2021-050995
  22. Comparison of Latencies and Time to Stabilization of Pulse Oximeters at a Tertiary Health Care Facility
  23. Hassan, A. T., Ahmed, S. M., AbdelHaffeez, A. S., & Mohamed, S. A. A. (2021). Accuracy and precision of pulse oximeter at different sensor locations in patients with heart failure. Multidisciplinary Respiratory Medicine, 16. https://doi.org/10.4081/mrm.2021.742