Published May 19, 2005 | Journal article | Version v1 | https://doi.org/10.1002/mrm.20482

3D MDEFT imaging of the human brain at 4.7 T with reduced sensitivity to radiofrequency inhomogeneity

Description

AbstractA modification to the 3D modified driven equilibrium Fourier transform (MDEFT) imaging technique is proposed that reduces its sensitivity to RF inhomogeneity. This is especially important at high field strengths where RF focusing effects exacerbate B1 inhomogeneity, causing significant signal nonuniformity in the images. The adiabatic inversion pulse used during the preparation period of the MDEFT sequence is replaced by a hard (nonadiabatic) pulse with a nominal flip angle of 130°. The spatial inhomogeneity of the hard pulse preparation compensates for the inhomogeneity of the excitation pulses. Uniform signal intensity is obtained for a wide range of B1 amplitudes and the high CNR characteristic of MDEFT is retained. The new approach was validated by numerical simulations and successfully applied to human brain imaging at 4.7 T, resulting in high‐quality T1‐weighted images of the whole human brain at high field strength with uniform signal intensity and contrast, despite the presence of significant RF inhomogeneity. Magn Reson Med 53:1452–1458, 2005. © 2005 Wiley‐Liss, Inc.

Additional details

Funding

ROR icon Wellcome Trust
Application for a 4.7 Tesla magnetic resonance research system to develop and apply non-invasive methods for measuring function, physiology and biochemistry in human brain. 045939

Dates

Issued
May 19, 2005

References

  1. Chen, C., Sank, V. J., Cohen, S. M., & Hoult, D. I. (1986). The field dependence of NMR imaging. I. Laboratory assessment of signal‐to‐noise ratio and power deposition. Magnetic Resonance in Medicine, 3(5), 722–729. https://doi.org/10.1002/mrm.1910030508
  2. Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., Vaughan, T., Van De Moortele, P.-F., Yacoub, E., & Zhu, X.-H. (2003). Ultrahigh field magnetic resonance imaging and spectroscopy. Magnetic Resonance Imaging, 21(10), 1263–1281. https://doi.org/10.1016/j.mri.2003.08.027
  3. Norris, D. G. (2003). High field human imaging. Journal of Magnetic Resonance Imaging, 18(5), 519–529. https://doi.org/10.1002/jmri.10390
  4. Hoult, D. I. (2000). Sensitivity and Power Deposition in a High-Field Imaging Experiment. Journal of Magnetic Resonance Imaging, 12(1), 46–67. https://doi.org/10.1002/1522-2586(200007)12:1%3C46::aid-jmri6%3E3.0.co;2-d
  5. Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., & Ugurbil, K. (2001). 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images. Magnetic Resonance in Medicine, 46(1), 24–30. https://doi.org/10.1002/mrm.1156
  6. https://doi.org/10.1148/radiology.199.3.8638004 https://doi.org/10.1148/radiology.199.3.8638004
  7. https://doi.org/10.1098/rstb.1999.0474 https://doi.org/10.1098/rstb.1999.0474
  8. https://doi.org/10.1259/bjr/69317841 https://doi.org/10.1259/bjr/69317841
  9. Thomas, D. L., De Vita, E., Roberts, S., Turner, R., Yousry, T. A., & Ordidge, R. J. (2004). High‐resolution fast spin echo imaging of the human brain at 4.7 T: Implementation and sequence characteristics. Magnetic Resonance in Medicine, 51(6), 1254–1264. https://doi.org/10.1002/mrm.20106
  10. Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K. (1995). High contrast and fast three‐dimensional magnetic resonance imaging at high fields. Magnetic Resonance in Medicine, 34(3), 308–312. https://doi.org/10.1002/mrm.1910340305
  11. Deichmann, R., Schwarzbauer, C., & Turner, R. (2004). Optimisation of the 3D MDEFT sequence for anatomical brain imaging: technical implications at 1.5 and 3 T. NeuroImage, 21(2), 757–767. https://doi.org/10.1016/j.neuroimage.2003.09.062
  12. Norris, D. G., Kangarlu, A., Schwarzbauer, C., Abduljalil, A. M., Christoforidis, G., & Robitaille, P.-M. L. (1999). MDEFT imaging of the human brain at 8 T. Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine, 9(1-2), 92–96. https://doi.org/10.1007/bf02634598
  13. Deichmann, R., Good, C. D., Josephs, O., Ashburner, J., & Turner, R. (2000). Optimization of 3-D MP-RAGE Sequences for Structural Brain Imaging. NeuroImage, 12(1), 112–127. https://doi.org/10.1006/nimg.2000.0601
  14. https://doi.org/10.1097/00004424-199005000-00015 https://doi.org/10.1097/00004424-199005000-00015
  15. Deichmann, R., Good, C. D., & Turner, R. (2002). RF inhomogeneity compensation in structural brain imaging. Magnetic Resonance in Medicine, 47(2), 398–402. https://doi.org/10.1002/mrm.10050
  16. Silver, M. S., Joseph, R. I., & Hoult, D. I. (1984). Highly selective and π pulse generation. Journal of Magnetic Resonance (1969), 59(2), 347–351. https://doi.org/10.1016/0022-2364(84)90181-1
  17. TakayaN WatanabeH andMitsumoriF.Elongated T1values in human brain and the optimization of MDEFT measurements at 4.7T. In: Proceedings of the 12th Annual Meeting of ISMRM Kyoto Japan 2004. p2339.
  18. van der Meulen P van YperenGH.A novel method for rapid pulse angle optimisation. In: Proceedings of the 5th Annual Meeting of SMRM 1986 . p1129.
  19. De VitaE ThomasDL DeichmannR TurnerR OrdidgeRJ.Fast B1 mapping with EPI. In: Proceedings of the 12th Annual Meeting of ISMRM Kyoto Japan 2004. p2090.
  20. Ashburner, J., & Friston, K. (1997). Multimodal Image Coregistration and Partitioning—A Unified Framework. NeuroImage, 6(3), 209–217. https://doi.org/10.1006/nimg.1997.0290
  21. Collins, C. M., & Smith, M. B. (2001). Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil. Magnetic Resonance in Medicine, 45(4), 684–691. https://doi.org/10.1002/mrm.1091

Citations

  1. https://doi.org/10.1109/icme51207.2021.9428437
  2. https://doi.org/10.1186/s13244-019-0821-8
  3. https://doi.org/10.3389/fncir.2019.00035
  4. https://doi.org/10.1101/105874
  5. https://doi.org/10.1186/s13640-017-0209-y
  6. Padormo, F., Hess, A. T., Aljabar, P., Malik, S. J., Jezzard, P., Robson, M. D., Hajnal, J. V., & Koopmans, P. J. (2015). Large dynamic range relative B1+ mapping: Large Dynamic Range Relative B1+ Mapping. Magnetic Resonance in Medicine, 76(2), 490–499. https://doi.org/10.1002/mrm.25884
  7. McPhee, K. C., & Wilman, A. H. (2015). T2 quantification from only proton density and T2-weighted MRI by modelling actual refocusing angles. NeuroImage, 118, 642–650. https://doi.org/10.1016/j.neuroimage.2015.05.079
  8. https://doi.org/10.5812/iranjradiol.22887
  9. Turner, R. (2013). MRI Methods for In-Vivo Cortical Parcellation. In Microstructural Parcellation of the Human Cerebral Cortex (pp. 197–220). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-37824-9_7
  10. Hu, X., Ackermann, H., Martin, J. A., Erb, M., Winkler, S., & Reiterer, S. M. (2013). Language aptitude for pronunciation in advanced second language (L2) Learners: Behavioural predictors and neural substrates. Brain and Language, 127(3), 366–376. https://doi.org/10.1016/j.bandl.2012.11.006
  11. Malik, S. J., Keihaninejad, S., Hammers, A., & Hajnal, J. V. (2011). Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses. Magnetic Resonance in Medicine, 67(5), 1303–1315. https://doi.org/10.1002/mrm.23118
  12. Hu, X., Erb, M., Ackermann, H., Martin, J. A., Grodd, W., & Reiterer, S. M. (2011). Voxel-based morphometry studies of personality: Issue of statistical model specification—effect of nuisance covariates. NeuroImage, 54(3), 1994–2005. https://doi.org/10.1016/j.neuroimage.2010.10.024
  13. https://doi.org/10.1109/icic.2011.106
  14. https://doi.org/10.1186/1745-6215-12-62
  15. Lutti, A., Hutton, C., Finsterbusch, J., Helms, G., & Weiskopf, N. (2010). Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T. Magnetic Resonance in Medicine, 64(1), 229–238. https://doi.org/10.1002/mrm.22421
  16. Gillet, B., Po, C., Dupont, D., Sébrié, C., & Méric, P. (2010). Manganèse et imagerie de résonance magnétique du développement cérébral. Comptes Rendus. Chimie, 13(4), 459–465. https://doi.org/10.1016/j.crci.2009.09.013
  17. Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010). MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field. NeuroImage, 49(2), 1271–1281. https://doi.org/10.1016/j.neuroimage.2009.10.002
  18. Abdul‐Kareem, I. A., Stancak, A., Parkes, L. M., & Sluming, V. (2009). Regional corpus callosum morphometry: Effect of field strength and pulse sequence. Journal of Magnetic Resonance Imaging, 30(5), 1184–1190. https://doi.org/10.1002/jmri.21932
  19. Tardif, C. L., Collins, D. L., & Pike, G. B. (2009). Sensitivity of voxel-based morphometry analysis to choice of imaging protocol at 3 T. NeuroImage, 44(3), 827–838. https://doi.org/10.1016/j.neuroimage.2008.09.053
  20. Shmueli, K., Thomas, D. L., & Ordidge, R. J. (2007). Design, construction and evaluation of an anthropomorphic head phantom with realistic susceptibility artifacts. Journal of Magnetic Resonance Imaging, 26(1), 202–207. https://doi.org/10.1002/jmri.20993
  21. Alagappan, V., Nistler, J., Adalsteinsson, E., Setsompop, K., Fontius, U., Zelinski, A., Vester, M., Wiggins, G. C., Hebrank, F., Renz, W., Schmitt, F., & Wald, L. L. (2007). Degenerate mode band‐pass birdcage coil for accelerated parallel excitation. Magnetic Resonance in Medicine, 57(6), 1148–1158. https://doi.org/10.1002/mrm.21247
  22. https://doi.org/10.1109/tmi.2006.891486
  23. Thomas, D. L., Lythgoe, M. F., Gadian, D. G., & Ordidge, R. J. (2006). In vivo measurement of the longitudinal relaxation time of arterial blood (T1a) in the mouse using a pulsed arterial spin labeling approach. Magnetic Resonance in Medicine, 55(4), 943–947. https://doi.org/10.1002/mrm.20823
  24. Schmitt, F., Potthast, A., Stoeckel, B., Triantafyllou, C., Wiggins, C. J., Wiggins, G., & Wald, L. L. (2006). Aspects of Clinical Imaging at 7 T. In Biological Magnetic Resonance (pp. 59–103). Springer US. https://doi.org/10.1007/978-0-387-49648-1_4
  25. Howarth, C., Hutton, C., & Deichmann, R. (2006). Improvement of the image quality of T1-weighted anatomical brain scans. NeuroImage, 29(3), 930–937. https://doi.org/10.1016/j.neuroimage.2005.08.004

1–25 of 26