Published March 2004 | Journal article | Version v1 | https://doi.org/10.1016/j.clinbiomech.2003.11.006

Quadriceps function after TKA––an in vitro study in a knee kinematic simulator

Additional details

Dates

Issued
March 2004

References

  1. Andriacchi, T. P., Galante, J. O., & Fermier, R. W. (1982). The influence of total knee-replacement design on walking and stair-climbing. The Journal of Bone & Joint Surgery, 64(9), 1328–1335. https://doi.org/10.2106/00004623-198264090-00008
  2. Biomechanics and gait analysis in total knee arthroplasty
  3. BERMAN, A. T., BOSACCO, S. J., & ISRAELITE, C. (1991). Evaluation of Total Knee Arthroplasty Using Isokinetic Testing. Clinical Orthopaedics and Related Research, 271, 106???113. https://doi.org/10.1097/00003086-199110000-00015
  4. Buechel, F. F., & Pappas, M. J. (1986). The New Jersey low-contact-stress knee replacement system: Biomechanical rationale and review of the first 123 cemented cases. Archives of Orthopaedic and Traumatic Surgery, 105(4), 197–204. https://doi.org/10.1007/bf00435480
  5. Dennis, D.A., 1998. Proposed Advantages of Posterior Cruciate Ligament Retention. Orthopaedics Today. New Jersey, Slack Incorporated, 1 (September/October) 10
  6. DORR, L. D., OCHSNER, J. L., GRONLEY, J., & PERRY, J. (1988). Functional Comparison of Posterior Cruciate Retained versus Cruciate-Sacrificed Total Knee Arthroplasty. Clinical Orthopaedics and Related Research, 236, 36–43. https://doi.org/10.1097/00003086-198811000-00005
  7. Draganich, L. F., Andriacchi, T. P., & Andersson, G. B. J. (1987). Interaction between intrinsic knee mechanics and the knee extensor mechanism. Journal of Orthopaedic Research, 5(4), 539–547. https://doi.org/10.1002/jor.1100050409
  8. Fuchs, S., Tibesku, C.O., Jerosch, J., 1998. Isokinetic measurements in total knee arthroplasty patients compared to healthy volunteers. Nice, 8th Congress of the European Society of Sports Traumatology, Knee Surgery and Arthroscospy
  9. Interax® Total-Kniesystem, 1994. Howmedica
  10. Jazrawi, L. M., Kummer, F. J., & DiCesare, P. E. (1998). Alternative Bearing Surfaces for Total Joint Arthroplasty. Journal of the American Academy of Orthopaedic Surgeons, 6(4), 198–203. https://doi.org/10.5435/00124635-199807000-00001
  11. Changes of axial tibial rotation caused by forced rotation at the weight-bearing knee studied by RSA https://doi.org/10.1302/0301-620x.82b8.10715
  12. Komistek, R. D., Dennis, D. A., Walker, S. A., & Anderson, D. T. (1998). A multicenter analysis of translation in TKA. Journal of Biomechanics, 31, 125. https://doi.org/10.1016/s0021-9290(98)80253-4
  13. LCS––20 Jahre Kniesystem, 1998, pp. 1–14
  14. Lewandowski, P. J., Askew, M. J., Lin, D. F., Hurst, F. W., & Melby, A. (1997). Kinematics of posterior cruciate ligament-retaining and -sacrificing mobile bearing total knee arthroplasties. The Journal of Arthroplasty, 12(7), 777–784. https://doi.org/10.1016/s0883-5403(97)90008-5
  15. More, R. C., Karras, B. T., Neiman, R., Fritschy, D., Woo, S. L.-Y., & Daniel, D. M. (1993). Hamstrings—an anterior cruciate ligament protagonist. The American Journal of Sports Medicine, 21(2), 231–237. https://doi.org/10.1177/036354659302100212
  16. Morra, E.A., Postak, P.D., Greenwald, A.S., 1998. The Influence of Mobile Bearing Knee Geometry on the Wear of UHMWPE tibial inserts: A finite Element study. Orthopaedic Research Laboratories, Ohio
  17. Nisell, R. (1985). Mechanics of the Knee. Acta Orthopaedica Scandinavica, 56(sup216), 1–42. https://doi.org/10.3109/17453678509154159
  18. Rand, J. A. (1994). The patellofemoral joint in total knee arthroplasty. The Journal of Bone & Joint Surgery, 76(4), 612–620. https://doi.org/10.2106/00004623-199404000-00019
  19. Stiehl, J. B., Komistek, R. D., Cloutier, J.-M., & Dennis, D. A. (2000). The cruciate ligaments in total knee arthroplasty. The Journal of Arthroplasty, 15(5), 545–550. https://doi.org/10.1054/arth.2000.4638
  20. Stukenborg-Colsman, C., Ostermeier, S., Hurschler, C., & Wirth, C. J. (2002). Tibiofemoral contact stress after total knee arthroplasty: Comparison of fixed and mobile-bearing inlay designs. Acta Orthopaedica Scandinavica, 73(6), 638–646. https://doi.org/10.1080/000164702321039598
  21. Stukenborg-Colsman, C., Ostermeier, S., Wenger, K. H., & Wirth, C. J. (2002). Relative motion of a mobile bearing inlay after total knee arthroplasty – dynamic in vitro study. Clinical Biomechanics, 17(1), 49–55. https://doi.org/10.1016/s0268-0033(01)00103-6
  22. Walker, P. S., & Sathasivam, S. (1999). The design of guide surfaces for fixed-bearing and mobile-bearing knee replacements. Journal of Biomechanics, 32(1), 27–34. https://doi.org/10.1016/s0021-9290(98)00140-7
  23. Wimmer, M.A., 1999. Wear of the Polyethylene Component Created by Rolling Motion of the Artificial Knee Joint. Aachen, Shaker
  24. Biomechanische Aspekte von Humangelenken

Citations

  1. https://doi.org/10.1109/icbea62825.2024.00025
  2. Ge, J., Hernigou, P., Guo, W., Zhang, N., Liu, C., & Zhang, Q. (2023). Minimally invasive small incision surgical technique for unicompartmental knee arthroplasty. International Orthopaedics, 47(11), 2717–2725. https://doi.org/10.1007/s00264-023-05908-5
  3. Mochizuki, T., Blaha, J. D., Tanifuji, O., Yamagiwa, H., Kai, S., & Kawashima, H. (2021). The three-dimensional quadriceps vector is most parallel to the spherical axis in Japanese varus osteoarthritic knees. The Knee, 33, 200–209. https://doi.org/10.1016/j.knee.2021.09.002
  4. https://doi.org/10.33894/mtk-2019.11.03
  5. Kang, K.-T., Kwon, S. K., Son, J., Kwon, O.-R., Lee, J.-S., & Koh, Y.-G. (2018). The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 26(10), 3188–3195. https://doi.org/10.1007/s00167-018-4925-3
  6. Kloos, F., Becher, C., Fleischer, B., Feucht, M. J., Hohloch, L., Südkamp, N., Niemeyer, P., & Bode, G. (2018). High tibial osteotomy increases patellofemoral pressure if adverted proximal, while open-wedge HTO with distal biplanar osteotomy discharges the patellofemoral joint: different open-wedge high tibial osteotomies compared to an extra-articular unloading device. Knee Surgery, Sports Traumatology, Arthroscopy, 27(7), 2334–2344. https://doi.org/10.1007/s00167-018-5194-x
  7. Tecame, A., Ferrari, M., Violante, B., Calafiore, G., Papalia, R., & Adravanti, P. (2018). Are contemporary femoral components sizing and design likely to affect functional results in TKA? A mathematical model of an implanted knee to predict knee forces. MUSCULOSKELETAL SURGERY, 102(3), 289–297. https://doi.org/10.1007/s12306-018-0533-0
  8. Kang, K.-T., Kwon, S. K., Son, J., Kwon, O.-R., Lee, J.-S., & Koh, Y.-G. (2018). Effects of posterior condylar offset and posterior tibial slope on mobile-bearing total knee arthroplasty using computational simulation. The Knee, 25(5), 903–914. https://doi.org/10.1016/j.knee.2018.06.011
  9. Ishii, Y., Noguchi, H., Sato, J., Ishii, H., Yamamoto, T., Sakurai, T., & Toyabe, S.-. ichi . (2017). Clinical relevance of active straight leg raising, standing up, and walking after total knee arthroplasty in a cross-sectional study. European Journal of Orthopaedic Surgery & Traumatology, 28(5), 947–953. https://doi.org/10.1007/s00590-017-2100-z
  10. Calliess, T., Ettinger, M., Schado, S., Becher, C., Hurschler, C., & Ostermeier, S. (2016). Patella tracking and patella contact pressure in modular patellofemoral arthroplasty: a biomechanical in vitro analysis. Archives of Orthopaedic and Trauma Surgery, 136(6), 849–855. https://doi.org/10.1007/s00402-016-2451-7
  11. Ali, A. A., Shalhoub, S. S., Cyr, A. J., Fitzpatrick, C. K., Maletsky, L. P., Rullkoetter, P. J., & Shelburne, K. B. (2016). Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee. Journal of Biomechanics, 49(2), 302–309. https://doi.org/10.1016/j.jbiomech.2015.12.020
  12. https://doi.org/10.1115/1.4034005
  13. Millán-Vaquero, R. M., Lynch, S. D., Fleischer, B., Rzepecki, J., Friese, K.-I., Hurschler, C., & Wolter, F.-E. (2015). Enhanced Visualization of the Knee Joint Functional Articulation Based on Helical Axis Method. In Informatik aktuell (pp. 449–454). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-662-46224-9_77
  14. Ettinger, M., Zoch, J. M., Becher, C., Hurschler, C., Stukenborg-Colsman, C., Claassen, L., Ostermeier, S., & Calliess, T. (2015). In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplasty. Archives of Orthopaedic and Trauma Surgery, 135(6), 871–877. https://doi.org/10.1007/s00402-015-2214-x
  15. Calliess, T., Schado, S., Richter, B. I., Becher, C., Ezechieli, M., & Ostermeier, S. (2014). Quadriceps force during knee extension in different replacement scenarios with a modular partial prosthesis. Clinical Biomechanics, 29(2), 218–222. https://doi.org/10.1016/j.clinbiomech.2013.11.007
  16. Indelli, P. F., Marcucci, M., Pipino, G., Charlton, S., Carulli, C., & Innocenti, M. (2013). The effects of femoral component design on the patello-femoral joint in a PS total knee arthroplasty. Archives of Orthopaedic and Trauma Surgery, 134(1), 59–64. https://doi.org/10.1007/s00402-013-1877-4
  17. Denkena, B., Köhler, J., Turger, A., Helmecke, P., Correa, T., & Hurschler, C. (2013). Manufacturing Conditioned Wear of All-ceramic Knee Prostheses. Procedia CIRP, 5, 179–184. https://doi.org/10.1016/j.procir.2013.01.036
  18. https://doi.org/10.1186/1475-925x-12-58
  19. Durairaj, R. B., Shanker, J., Vinoth Kumar, P., & Sivasankar, M. (2012). A Study on Development of Knee Simulator for Testing Artificial Knee Prosthesis. In Lecture Notes in Mechanical Engineering (pp. 351–360). Springer India. https://doi.org/10.1007/978-81-322-1007-8_32
  20. Leszko, F. (2012). Biomechanics and Vibroarthrography of the Patellofemoral Joint. In Insall &amp Scott Surgery of the Knee (pp. e14-1-e14-19). Elsevier. https://doi.org/10.1016/b978-1-4377-1503-3.00014-7
  21. https://doi.org/10.1302/0301-620x.94b1.27514
  22. Becher, C., Heyse, T. J., Kron, N., Ostermeier, S., Hurschler, C., Schofer, M. D., Fuchs‐Winkelmann, S., & Tibesku, C. O. (2009). Posterior stabilized TKA reduce patellofemoral contact pressure compared with cruciate retaining TKA in vitro. Knee Surgery, Sports Traumatology, Arthroscopy, 17(10), 1159–1165. https://doi.org/10.1007/s00167-009-0768-2
  23. Heyse, T. J., Becher, C., Kron, N., Ostermeier, S., Hurschler, C., Schofer, M. D., Tibesku, C. O., & Fuchs-Winkelmann, S. (2009). Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays. Archives of Orthopaedic and Trauma Surgery, 130(2), 191–196. https://doi.org/10.1007/s00402-009-0920-y
  24. Heyse, T. J., Becher, C., Kron, N., Ostermeier, S., Hurschler, C., Schofer, M. D., Fuchs-Winkelmann, S., & Tibesku, C. O. (2009). Quadriceps force in relation of intrinsic anteroposterior stability of TKA design. Archives of Orthopaedic and Trauma Surgery, 130(1), 1–9. https://doi.org/10.1007/s00402-009-0927-4
  25. Ostermeier, S., Bohnsack, M., Hurschler, C., & Stukenborg-Colsman, C. (2009). A rotating inlay decreases contact pressure on inlay post after posterior cruciate substituting total knee arthroplasty. Clinical Biomechanics, 24(5), 446–450. https://doi.org/10.1016/j.clinbiomech.2009.03.006

1–25 of 35