Skip to main
Washout of 82Rb as a marker of impaired tissue integrity, obtained by list-mode cardiac PET/CT: relationship with perfusion/metabolism patterns of myocardial viability
Authors/Creators
Chien, David T. 1, 2
Bravo, Paco 1, 2
Higuchi, Takahiro 1, 2
Merrill, Jennifer 1, 2
Bengel, Frank M. 1, 2, 3
Show affiliations
Additional details
Mullani NA, Goldstein RA, Gould KL, Marani SK, Fisher DJ, O'Brien HA, et al. Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors. J Nucl Med 1983;24:898–906.
Bengel, F. M., Higuchi, T., Javadi, M. S., & Lautamäki, R. (2009). Cardiac Positron Emission Tomography. Journal of the American College of Cardiology , 54 (1), 1–15.
https://doi.org/10.1016/j.jacc.2009.02.065
Di Carli, M. F., & Hachamovitch, R. (2007). New Technology for Noninvasive Evaluation of Coronary Artery Disease. Circulation , 115 (11), 1464–1480.
https://doi.org/10.1161/circulationaha.106.629808
Gould KL, Yoshida K, Hess MJ, Haynie M, Mullani N, Smalling RW. Myocardial metabolism of fluorodeoxyglucose compared to cell membrane integrity for the potassium analogue rubidium-82 for assessing infarct size in man by PET. J Nucl Med 1991;32:1–9.
vom Dahl, J., Muzik, O., Wolfe, E. R., Allman, C., Hutchins, G., & Schwaiger, M. (1996). Myocardial Rubidium-82 Tissue Kinetics Assessed by Dynamic Positron Emission Tomography as a Marker of Myocardial Cell Membrane Integrity and Viability. Circulation , 93 (2), 238–245.
https://doi.org/10.1161/01.cir.93.2.238
Stankewicz MA, Mansour CS, Eisner RL, Churchwell KB, Williams BR, Sigman SR, et al. Myocardial viability assessment by PET: (82)Rb defect washout does not predict the results of metabolic-perfusion mismatch. J Nucl Med 2005;46:1602–9.
Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ, National Electrical Manufacturers Association (NEMA). NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med 2006;47:1960–7.
Lautamäki, R., Brown, T. L. Y., Merrill, J., & Bengel, F. M. (2007). CT-based attenuation correction in 82Rb-myocardial perfusion PET–CT: incidence of misalignment and effect on regional tracer distribution. European Journal of Nuclear Medicine and Molecular Imaging , 35 (2), 305–310.
https://doi.org/10.1007/s00259-007-0607-y
Chander, A., Brenner, M., Lautamäki, R., Voicu, C., Merrill, J., & Bengel, F. M. (2008). Comparison of Measures of Left Ventricular Function from Electrocardiographically Gated 82 Rb PET with Contrast-Enhanced CT Ventriculography: A Hybrid PET/CT Analysis. Journal of Nuclear Medicine , 49 (10), 1643–1650.
https://doi.org/10.2967/jnumed.108.053819
Nekolla, S. G., Miethaner, C., Nguyen, N., Ziegler, S. I., & Schwaiger, M. (1998). Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography. European Journal of Nuclear Medicine and Molecular Imaging , 25 (9), 1313–1321.
https://doi.org/10.1007/s002590050301
Imaging:, A. H. A. W. G. on M. S. and R. for C., Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., & Verani, M. S. (2002). Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart. Circulation , 105 (4), 539–542.
https://doi.org/10.1161/hc0402.102975
Lautamäki, R., George, R. T., Kitagawa, K., Higuchi, T., Merrill, J., Voicu, C., DiPaula, A., Nekolla, S. G., Lima, J. A. C., Lardo, A. C., & Bengel, F. M. (2008). Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: validation in a canine model of coronary artery stenosis. European Journal of Nuclear Medicine and Molecular Imaging , 36 (4), 576–586.
https://doi.org/10.1007/s00259-008-0972-1
Beanlands RS, Hendry PJ, Masters RG, deKemp RA, Woodend K, Ruddy TD. Delay in revascularization is associated with increased mortality rate in patients with severe left ventricular dysfunction and viable myocardium on fluorine 18-fluorodeoxyglucose positron emission tomography imaging. Circulation 1998;98(19 Suppl):II51–6.
Haas, F., Augustin, N., Holper, K., Wottke, M., Haehnel, C., Nekolla, S., Meisner, H., Lange, R., & Schwaiger, M. (2000). Time course and extent of improvement of dysfunctioning myocardium in patients with coronary artery disease and severely depressed left ventricular function after revascularization: correlation with positron emission tomographic findings. Journal of the American College of Cardiology , 36 (6), 1927–1934.
https://doi.org/10.1016/s0735-1097(00)00968-2
Maes, A., Flameng, W., Nuyts, J., Borgers, M., Shivalkar, B., Ausma, J., Bormans, G., Schiepers, C., De Roo, M., & Mortelmans, L. (1994). Histological alterations in chronically hypoperfused myocardium. Correlation with PET findings. Circulation , 90 (2), 735–745.
https://doi.org/10.1161/01.cir.90.2.735
Knuesel, P. R., Nanz, D., Wyss, C., Buechi, M., Kaufmann, P. A., von Schulthess, G. K., Lüscher, T. F., & Schwitter, J. (2003). Characterization of Dysfunctional Myocardium by Positron Emission Tomography and Magnetic Resonance. Circulation , 108 (9), 1095–1100.
https://doi.org/10.1161/01.cir.0000085993.93936.ba
Grunwald, A. M., Watson, D. D., Holzgrefe, H. H., Irving, J. F., & Beller, G. A. (1981). Myocardial thallium-201 kinetics in normal and ischemic myocardium. Circulation , 64 (3), 610–618.
https://doi.org/10.1161/01.cir.64.3.610
Brown KA, Benoit L, Clements JP, Wackers FJ. Fast washout of thallium-201 from area of myocardial infarction: possible artifact of background subtraction. J Nucl Med 1987;28:945–9.
Machac, J. (2005). Cardiac positron emission tomography imaging. Seminars in Nuclear Medicine , 35 (1), 17–36.
https://doi.org/10.1053/j.semnuclmed.2004.09.002
Buechel, R. R., Ciancone, D., Bakula, A., von Felten, E., Schmidt, G.-A., Patriki, D., Gräni, C., Wahl, A., Manka, R., Heidecker, B., Benz, D. C., Giannopoulos, A. A., Pazhenkottil, A. P., & Kaufmann, P. A. (2023). Long-term impact of myocardial inflammation on quantitative myocardial perfusion—a descriptive PET/MR myocarditis study. European Journal of Nuclear Medicine and Molecular Imaging , 50 (12), 3609–3618.
https://doi.org/10.1007/s00259-023-06314-0
Benz, D. C., Ferro, P., Safa, N., Messerli, M., von Felten, E., Huang, W., Patriki, D., Giannopoulos, A. A., Fuchs, T. A., Gräni, C., Gebhard, C., Pazhenkottil, A. P., Kaufmann, P. A., & Buechel, R. R. (2021). Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy. Journal of Nuclear Cardiology , 28 (1), 263–273.
https://doi.org/10.1007/s12350-019-01684-1
Lang, J. K., & Canty, J. M. (2021). The complexity of using resting myocardial perfusion to assess myocardial viability and predict functional recovery. Journal of Nuclear Cardiology , 28 (1), 274–277.
https://doi.org/10.1007/s12350-019-01742-8
Madsen, S., Dias, A. H., Lauritsen, K. M., Bouchelouche, K., Tolbod, L. P., & Gormsen, L. C. (2020). Myocardial Viability Testing by Positron Emission Tomography: Basic Concepts, Mini-Review of the Literature and Experience From a Tertiary PET Center. Seminars in Nuclear Medicine , 50 (3), 248–259.
https://doi.org/10.1053/j.semnuclmed.2020.02.010
Moody, J. B., Hiller, K. M., Lee, B. C., Poitrasson-Rivière, A., Corbett, J. R., Weinberg, R. L., Murthy, V. L., & Ficaro, E. P. (2019). The utility of 82Rb PET for myocardial viability assessment: Comparison with perfusion-metabolism 82Rb-18F-FDG PET. Journal of Nuclear Cardiology , 26 (2), 374–386.
https://doi.org/10.1007/s12350-019-01615-0
Tuffier, S., Legallois, D., Belin, A., Joubert, M., Bailliez, A., Redonnet, M., Agostini, D., & Manrique, A. (2015). Assessment of endothelial function and myocardial flow reserve using 15O-water PET without attenuation correction. European Journal of Nuclear Medicine and Molecular Imaging , 43 (2), 288–295.
https://doi.org/10.1007/s00259-015-3163-x