Scanning laser optical tomography for in toto imaging of the murine cochlea
Authors/Creators
Contributors
Editor:
Additional details
Identifiers
- OpenAlex
- W2604203970
- PMID
- 28388662
- URL
- https://dx.plos.org/10.1371/journal.pone.0175431
Funding
-
Deutsche Forschungsgemeinschaft
- EXC 1077/1
-
Volkswagen Foundation
- VWZN2860
- Ministry of Lower Saxony
- VWZN2860
-
Deutsche Forschungsgemeinschaft
- Hearing4all
-
Deutsche Forschungsgemeinschaft
- EXC-1077
-
Deutsche Forschungsgemeinschaft
- 1077/1
-
Volkswagen Foundation
- BIOFABRICATION FOR NIFE: VWZN2860
Dates
- Issued
-
April 7, 2017
References
- Coleman, B., Rickard, N. A., de Silva, M. G., & Shepherd, R. K. (2009). A protocol for cryoembedding the adult guinea pig cochlea for fluorescence immunohistology. Journal of Neuroscience Methods, 176(2), 144–151. https://doi.org/10.1016/j.jneumeth.2008.09.007
- Manji, S. S. M., Miller, K. A., Williams, L. H., & Dahl, H.-H. M. (2012). Identification of Three Novel Hearing Loss Mouse Strains with Mutations in the Tmc1 Gene. The American Journal of Pathology, 180(4), 1560–1569. https://doi.org/10.1016/j.ajpath.2011.12.034
- Cochlear length determination in temporal bone specimens using histological serial Micro grinding imaging, micro computed tomography and flat-panel volumetric computed tomography
- Wada, H., Sugawara, M., Kobayashi, T., Hozawa, K., & Takasaka, T. (1998). Measurement of guinea pig basilar membrane using computer-aided three-dimensional reconstruction system. Hearing Research, 120(1-2), 1–6. https://doi.org/10.1016/s0378-5955(98)00007-0
- Plassmann, W., Peetz, W., & Schmidt, M. (2008). The Cochlea in Gerbilline Rodents. Brain, Behavior and Evolution, 82–102. https://doi.org/10.1159/000118639
- Kawano, A., Seldon, H. L., & Clark, G. M. (1996). Computer-Aided Three-Dimensional Reconstruction in Human Cochlear Maps: Measurement of the Lengths of Organ of Corti, Outer Wall, Inner Wall, and Rosenthal's Canal. Annals of Otology, Rhinology & Laryngology, 105(9), 701–709. https://doi.org/10.1177/000348949610500906
- Ariyasu, L., Galey, F. R., Hilsinger, R., & Byl, F. M. (1989). Computer‐Generated Three‐Dimensional Reconstruction of the Cochlea. Otolaryngology–Head and Neck Surgery, 100(2), 87–91. https://doi.org/10.1177/019459988910000201
- Sato, M., Henson, M. M., Henson, O. W., & Smith, D. W. (1999). The innervation of outer hair cells: 3D reconstruction from TEM serial sections in the Japanese macaque. Hearing Research, 135(1-2), 29–38. https://doi.org/10.1016/s0378-5955(99)00086-6
- Christensen, G. E., He, J., Dill, J. A., Rubinstein, J. T., Vannier, M. W., & Wang, G. (2003). Automatic measurement of the labyrinth using image registration and a deformable inner ear atlas. Academic Radiology, 10(9), 988–999. https://doi.org/10.1016/s1076-6332(03)00121-1
- Spoor, F., & Zonneveld, F. (1998). Comparative review of the human bony labyrinth. American Journal of Physical Anthropology, 107(S27), 211–251. https://doi.org/10.1002/(sici)1096-8644(1998)107:27+%3C211::aid-ajpa8%3E3.0.co;2-v
- Yoo, S. K., Ge Wang, Rubinstein, J. T., & Vannier, M. W. (2000). Three-dimensional geometric modeling of the cochlea using helico-spiral approximation. IEEE Transactions on Biomedical Engineering, 47(10), 1392–1402. https://doi.org/10.1109/10.871413
- Poznyakovskiy, A. A., Zahnert, T., Kalaidzidis, Y., Schmidt, R., Fischer, B., Baumgart, J., & Yarin, Y. M. (2008). The creation of geometric three-dimensional models of the inner ear based on micro computer tomography data. Hearing Research, 243(1-2), 95–104. https://doi.org/10.1016/j.heares.2008.06.008
- Thorne, M., Salt, A. N., DeMott, J. E., Henson, M. M., Henson, O. W., & Gewalt, S. L. (1999). Cochlear Fluid Space Dimensions for Six Species Derived From Reconstructions of Three‐Dimensional Magnetic Resonance Images. The Laryngoscope, 109(10), 1661–1668. https://doi.org/10.1097/00005537-199910000-00021
- Benveniste, H., & Blackband, S. (2002). MR microscopy and high resolution small animal MRI: applications in neuroscience research. Progress in Neurobiology, 67(5), 393–420. https://doi.org/10.1016/s0301-0082(02)00020-5
- Hardie, N. A., MacDonald, G., & Rubel, E. W. (2004). A new method for imaging and 3D reconstruction of mammalian cochlea by fluorescent confocal microscopy. Brain Research, 1000(1-2), 200–210. https://doi.org/10.1016/j.brainres.2003.10.071
- MacDonald, G. H., & Rubel, E. W. (2008). Three-dimensional imaging of the intact mouse cochlea by fluorescent laser scanning confocal microscopy. Hearing Research, 243(1-2), 1–10. https://doi.org/10.1016/j.heares.2008.05.009
- Spalteholz W. Über das Durchsichtigmachen von menschlichen und tierischen Präparaten und seine theoretischen Bedingungen. S. Hirzel; 1914.
- Santi, P. A., Johnson, S. B., Hillenbrand, M., Grandpre, P. Z., Glass, T. J., & Leger, J. R. (2009). Thin-sheet laser imaging microscopy for optical sectioning of thick tissues. BioTechniques, 46(4), 287–294. https://doi.org/10.2144/000113087
- Voie, A. H. (2002). Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy. Hearing Research, 171(1-2), 119–128. https://doi.org/10.1016/s0378-5955(02)00493-8
- VOIE, A. H., BURNS, D. H., & SPELMAN, F. A. (1993). Orthogonal‐plane fluorescence optical sectioning: Three‐dimensional imaging of macroscopic biological specimens. Journal of Microscopy, 170(3), 229–236. https://doi.org/10.1111/j.1365-2818.1993.tb03346.x
- Orthogonal-plane fluorescence optical sectioning: a technique for 3-D imaging of biomedical specimens
- Tinne, N., Nolte, L., Antonopoulos, G. C., Schulze, J., Andrade, J., Heisterkamp, A., Meyer, H., Warnecke, A., Majdani, O., Ripken, T., Choi, B., Kollias, N., Zeng, H., Kang, H. W., Wong, B. J. F., Ilgner, J. F., Tearney, G. J., Gregory, K. W., Marcu, L., … Morris, M. D. (2016). Three-dimensional imaging of intracochlear tissue by scanning laser optical tomography (SLOT). SPIE Proceedings, 9689, 96892H. https://doi.org/10.1117/12.2211066
- Kellner, M., Heidrich, M., Beigel, R., Lorbeer, R.-A., Knudsen, L., Ripken, T., Heisterkamp, A., Meyer, H., Kühnel, M. P., & Ochs, M. (2012). Imaging of the mouse lung with scanning laser optical tomography (SLOT). Journal of Applied Physiology, 113(6), 975–983. https://doi.org/10.1152/japplphysiol.00026.2012
- Lorbeer, R.-A., Heidrich, M., Lorbeer, C., Ojeda, D. F. R., Bicker, G., Meyer, H., & Heisterkamp, A. (2011). Highly efficient 3D fluorescence microscopy with a scanning laser optical tomograph. Optics Express, 19(6), 5419. https://doi.org/10.1364/oe.19.005419
- Computer visualization of three-dimensional image data using IMOD
1–25 of 33
Citations
- Benecke, H., Almadani, F., Heske, J., May, T., Overmeyer, L., Johannsmeier, S., Ripken, T., & Wu, X. (2025). Automated sample tracking and parameter adaption for scanning laser optical tomography. PLOS ONE, 20(3), e0318974. https://doi.org/10.1371/journal.pone.0318974
- Benecke, H., Johannsmeier, S., May, T., & Ripken, T. (2024). Investigation of a hyperspectral Scanning Laser Optical Tomography setup for label-free cell identification. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-68685-0
- Urata, S., & Okabe, S. (2023). Three-dimensional mouse cochlea imaging based on the modified Sca/eS using confocal microscopy. Anatomical Science International, 98(3), 309–317. https://doi.org/10.1007/s12565-023-00703-z
- Malfeld, K., Armbrecht, N., Volk, H. A., Lenarz, T., & Scheper, V. (2021). In Situ 3D-Imaging of the Inner Ear Synapses with a Cochlear Implant. Life, 11(4), 301. https://doi.org/10.3390/life11040301
- Hutson, K. A., Pulver, S. H., Ariel, P., Naso, C., & Fitzpatrick, D. C. (2020). Light sheet microscopy of the gerbil cochlea. Journal of Comparative Neurology, 529(4), 757–785. https://doi.org/10.1002/cne.24977
- Bode, K., Nolte, L., Kamin, H., Desens, M., Ulmann, A., Bergmann, G. A., Betker, P., Reitmeier, J., Ripken, T., Stern, M., Meyer, H., & Bicker, G. (2020). Scanning laser optical tomography resolves developmental neurotoxic effects on pioneer neurons. Scientific Reports, 10(1). https://doi.org/10.1038/s41598-020-59562-7
- Moatti, A., Cai, Y., Li, C., Sattler, T., Edwards, L., Piedrahita, J., Ligler, F. S., & Greenbaum, A. (2020). Three-dimensional imaging of intact porcine cochlea using tissue clearing and custom-built light-sheet microscopy. Biomedical Optics Express, 11(11), 6181. https://doi.org/10.1364/boe.402991
- Matryba, P., Kaczmarek, L., & Gołąb, J. (2019). Advances in Ex Situ Tissue Optical Clearing. Laser & Photonics Reviews, 13(8). https://doi.org/10.1002/lpor.201800292
- Schulze, J., Nolte, L., Lyutenski, S., Tinne, N., Heinemann, D., Ripken, T., Willaredt, M. A., Nothwang, H. G., Lenarz, T., & Warnecke, A. (2019). Scannende laseroptische Tomographie in einem neuropathischen Mausmodell: Visualisierung von strukturellen Veränderungen. HNO, 67(8), 590–599. https://doi.org/10.1007/s00106-019-0652-4
- Schulze, J., Nolte, L., Lyutenski, S., Tinne, N., Heinemann, D., Ripken, T., Willaredt, M. A., Nothwang, H. G., Lenarz, T., & Warnecke, A. (2019). Scanning laser optical tomography in a neuropathic mouse model: Visualization of structural changes. HNO, 67(S2), 69–76. https://doi.org/10.1007/s00106-019-0654-2
- Elkaseer, A., Salem, M., Hagenmeyer, V., & Scholz, S. (2019). Vision system-based inspection and alignment of laminated polymer films for 3D-Integration of microsystems. IFAC-PapersOnLine, 52(15), 13–18. https://doi.org/10.1016/j.ifacol.2019.11.642
- Urata, S., Iida, T., Yamamoto, M., Mizushima, Y., Fujimoto, C., Matsumoto, Y., Yamasoba, T., & Okabe, S. (2019). Cellular cartography of the organ of Corti based on optical tissue clearing and machine learning. eLife, 8. https://doi.org/10.7554/elife.40946
- Chen, L., Li, G., Tang, L., Zhang, M., Liu, L., Liu, A., McGinty, J., & Ruan, S. (2018). Hyperspectral scanning laser optical tomography. Journal of Biophotonics, 12(4). https://doi.org/10.1002/jbio.201800221
- Nolte, L., Antonopoulos, G. C., Rämisch, L., Heisterkamp, A., Ripken, T., & Meyer, H. (2018). Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT). Biomedical Optics Express, 9(6), 2627. https://doi.org/10.1364/boe.9.002627
- Ingendoh-Tsakmakidis, A., Nolte, L., Winkel, A., Meyer, H., Koroleva, A., Shpichka, A., Ripken, T., Heisterkamp, A., Stiesch, M., & Riveiro Rodríguez, A. (2018). Time resolved 3D live-cell imaging on implants. PLOS ONE, 13(10), e0205411. https://doi.org/10.1371/journal.pone.0205411
- Tinne, N., Antonopoulos, G. C., Mohebbi, S., Andrade, J., Nolte, L., Meyer, H., Heisterkamp, A., Majdani, O., Ripken, T., & Aegerter, C. M. (2017). Three-dimensional hard and soft tissue imaging of the human cochlea by scanning laser optical tomography (SLOT). PLOS ONE, 12(9), e0184069. https://doi.org/10.1371/journal.pone.0184069
- Mirsalehi, M., Mohebbi, S., Ebrahimpoor, S., Kuhnel, M. P., Lenarz, T., & Majdani, O. (2017). Preparation of Human Inner Ear Structures for High Resolution Imaging Studies. Archives of Neuroscience, In Press(In Press). https://doi.org/10.5812/archneurosci.14491