Published February 2016 | Journal article | Version v1 | https://doi.org/10.1016/j.msec.2015.11.037

Examination of a biodegradable magnesium screw for the reconstruction of the anterior cruciate ligament: A pilot in vivo study in rabbits

Additional details

Funding

DFG
SFB 599

Dates

Issued
February 2016

References

  1. Claes, S., Hermie, L., Verdonk, R., Bellemans, J., & Verdonk, P. (2012). Is osteoarthritis an inevitable consequence of anterior cruciate ligament reconstruction? A meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy, 21(9), 1967–1976. https://doi.org/10.1007/s00167-012-2251-8
  2. Marx, R. G., Jones, E. C., Angel, M., Wickiewicz, T. L., & Warren, R. F. (2003). Beliefs and attitudes of members of the American Academy of orthopaedic surgeons regarding the treatment of anterior cruciate ligament injury. Arthroscopy, 19(7), 762–770. https://doi.org/10.1016/s0749-8063(03)00398-0
  3. Mirza, F., Mai, D. D., Kirkley, A., Fowler, P. J., & Amendola, A. (2000). Management of Injuries to the Anterior Cruciate Ligament: Results of a Survey of Orthopaedic Surgeons in Canada. Clinical Journal of Sport Medicine, 10(2), 85–88. https://doi.org/10.1097/00042752-200004000-00001
  4. Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995). Preliminary results of an absorbable interference screw. Arthroscopy: The Journal of Arthroscopic & Related Surgery, 11(5), 537–548. https://doi.org/10.1016/0749-8063(95)90129-9
  5. Barber, F. A., & Dockery, W. D. (2006). Long-Term Absorption of Poly-L-Lactic Acid Interference Screws. Arthroscopy: The Journal of Arthroscopic & Related Surgery, 22(8), 820–826. https://doi.org/10.1016/j.arthro.2006.04.096
  6. Emond, C. E., Woelber, E. B., Kurd, S. K., Ciccotti, M. G., & Cohen, S. B. (2011). A Comparison of the Results of Anterior Cruciate Ligament Reconstruction Using Bioabsorbable Versus Metal Interference Screws. The Journal of Bone and Joint Surgery-American Volume, 93(6), 572–580. https://doi.org/10.2106/jbjs.j.00269
  7. Ettinger, M., Wehrhahn, T., Petri, M., Liodakis, E., Olender, G., Albrecht, U. ‐V ., Hurschler, C., Krettek, C., & Jagodzinski, M. (2011). The fixation strength of tibial PCL press‐fit reconstructions. Knee Surgery, Sports Traumatology, Arthroscopy, 20(2), 308–314. https://doi.org/10.1007/s00167-011-1584-z
  8. Synovitis of the knee after intraarticular fracture fixation with Biofix. Report of two cases
  9. Baums, M. H., Zelle, B. A., Schultz, W., Ernstberger, T., & Klinger, H. ‐M . (2006). Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction. Knee Surgery, Sports Traumatology, Arthroscopy, 14(9), 865–868. https://doi.org/10.1007/s00167-006-0049-2
  10. Krappel, F. A., Bauer, E., & Harland, U. (2006). The migration of a BioScrew® as a differential diagnosis of knee pain, locking after ACL reconstruction: a report of two cases. Archives of Orthopaedic and Trauma Surgery, 126(9), 615–620. https://doi.org/10.1007/s00402-006-0101-1
  11. Lembeck, B., & Wülker, N. (2004). Severe cartilage damage by broken poly–L–lactic acid (PLLA) interference screw after ACL reconstruction. Knee Surgery, Sports Traumatology, Arthroscopy, 13(4), 283–286. https://doi.org/10.1007/s00167-004-0545-1
  12. Waizy, H., Seitz, J.-M., Reifenrath, J., Weizbauer, A., Bach, F.-W., Meyer-Lindenberg, A., Denkena, B., & Windhagen, H. (2012). Biodegradable magnesium implants for orthopedic applications. Journal of Materials Science, 48(1), 39–50. https://doi.org/10.1007/s10853-012-6572-2
  13. Nagels, J., Stokdijk, M., & Rozing, P. M. (2003). Stress shielding and bone resorption in shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 12(1), 35–39. https://doi.org/10.1067/mse.2003.22
  14. Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006). Magnesium and its alloys as orthopedic biomaterials: A review. Biomaterials, 27(9), 1728–1734. https://doi.org/10.1016/j.biomaterials.2005.10.003
  15. Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005). In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials, 26(17), 3557–3563. https://doi.org/10.1016/j.biomaterials.2004.09.049
  16. Ezechieli, M., Diekmann, J., Weizbauer, A., Becher, C., Willbold, E., Helmecke, P., Lucas, A., Schavan, R., & Windhagen, H. (2014). Biodegradation of a magnesium alloy implant in the intercondylar femoral notch showed an appropriate response to the synovial membrane in a rabbit model in vivo. Journal of Biomaterials Applications, 29(2), 291–302. https://doi.org/10.1177/0885328214523322
  17. Waizy, H., Diekmann, J., Weizbauer, A., Reifenrath, J., Bartsch, I., Neubert, V., Schavan, R., & Windhagen, H. (2013). In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months. Journal of Biomaterials Applications, 28(5), 667–675. https://doi.org/10.1177/0885328212472215
  18. Windhagen, H., Radtke, K., Weizbauer, A., Diekmann, J., Noll, Y., Kreimeyer, U., Schavan, R., Stukenborg-Colsman, C., & Waizy, H. (2013). Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study. BioMedical Engineering OnLine, 12(1). https://doi.org/10.1186/1475-925x-12-62
  19. Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads
  20. Yamakado, K., Kitaoka, K., Yamada, H., Hashiba, K., Nakamura, R., & Tomita, K. (2002). The influence of mechanical stress on graft healing in a bone tunnel. Arthroscopy, 18(1), 82–90. https://doi.org/10.1053/jars.2002.25966
  21. Heitland, P., & Köster, H. D. (2006). Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP–MS. Journal of Trace Elements in Medicine and Biology, 20(4), 253–262. https://doi.org/10.1016/j.jtemb.2006.08.001
  22. Rodushkin, I., Ödman, F., & Branth, S. (1999). Multielement analysis of whole blood by high resolution inductively coupled plasma mass spectrometry. Fresenius' Journal of Analytical Chemistry, 364(4), 338–346. https://doi.org/10.1007/s002160051346
  23. Witte, F., Fischer, J., Nellesen, J., Vogt, C., Vogt, J., Donath, T., & Beckmann, F. (2010). In vivo corrosion and corrosion protection of magnesium alloy LAE442☆. Acta Biomaterialia, 6(5), 1792–1799. https://doi.org/10.1016/j.actbio.2009.10.012
  24. Willbold, E., & Witte, F. (2010). Histology and research at the hard tissue–implant interface using Technovit 9100 New embedding technique. Acta Biomaterialia, 6(11), 4447–4455. https://doi.org/10.1016/j.actbio.2010.06.022
  25. Donath, K., & Breuner, G. (1982). A method for the study of undecalcified bones and teeth with attached soft tissues*: The Säge‐Schliff (sawing and grinding) Technique. Journal of Oral Pathology & Medicine, 11(4), 318–326. https://doi.org/10.1111/j.1600-0714.1982.tb00172.x

1–25 of 47

Citations

  1. Xu, Y., Huang, Y., Armstrong, J., Xu, W., Biglino, G., Zhang, W., Qi, Q., Chen, X., Abram, S., Vyas, C., Da Silva Bartolo, P. J., & Liu, F. (2026). Recent advances in biomaterials and structural design of 3D printed multiphasic scaffolds for osteochondral regeneration. Materials Science and Engineering: R: Reports, 170, Article 101210. https://doi.org/10.1016/j.mser.2026.101210
  2. Yao, X., Wang, Y., Chen, X., Duan, S., Yao, H., Zeng, D., Wang, Y., Zhou, S., & Li, R. (2026). Magnesium alloys for bone-tendon interface regeneration: Biological mechanisms, alloying strategies, and self-healing coatings. Materials Today Advances, 31, 100965. https://doi.org/10.1016/j.mtadv.2026.100965
  3. Gao, X., Zhu, Z., Zhang, H., Yang, J., Zhu, Z., & Tiwari, S. K. (2025). Research Progress on Corrosion Behavior of Magnesium Alloy Composites in Practical Service Conditions. Advanced Sustainable Systems, 9(10). https://doi.org/10.1002/adsu.202500660
  4. Feng, X., Luo, Z., Shi, H., Chen, S., Chen, C., Chen, P., Zheng, S., Wan, R., Wang, Q., Li, Z., Lin, C., He, Y., Zhao, Z., Zhang, X., Zhou, X., Chen, Y., Li, Y., Liu, Q., & Chen, S. (2025). Advances in artificial ligament biomaterials for anterior cruciate ligament reconstruction: material innovation, surface modification, and novel adjuvant methods. Advanced Composites and Hybrid Materials, 8(4), Article 282. https://doi.org/10.1007/s42114-025-01307-z
  5. Sun, Y., Zhang, X., Yuan, K., Lou, J., Yu, J., Yu, H., Wang, W., & Zhang, X. (2025). Particles generated from degrading magnesium implants induce bone resorption. Composites Part B: Engineering, 296, 112241. https://doi.org/10.1016/j.compositesb.2025.112241
  6. Zhang, H., Chen, X., Ong, M. T.-Y., Lei, L., Zheng, L., Dai, B., Tong, W., Fu, B. S.-C., Xu, J., Yung, P. S.-H., & Qin, L. (2025). Current Advances of Artificial Ligaments for Anterior Cruciate Ligament Reconstruction: From Biocompatibility to Bioactivity. Engineering, 46, 47–59. https://doi.org/10.1016/j.eng.2024.10.018
  7. Wu, C., Lin, F., Liu, H., Pelletier, M. H., Lloyd, M., Walsh, W. R., & Nie, J.-F. (2025). Stronger and coarser-grained biodegradable zinc alloys. Nature, 638(8051), 684–689. https://doi.org/10.1038/s41586-024-08415-8
  8. https://doi.org/10.3390/ijms26073085
  9. Chang, C., Chen, C., Wang, J., Ren, Z., Liao, H., Liu, M., & Yan, X. (2024). Metallic and bone tissue advancements: materials, applications, and case studies. In Additive Manufacturing Materials and Technology (pp. 413–444). Elsevier. https://doi.org/10.1016/b978-0-443-18462-8.00017-9
  10. Riyaz, S., Sun, Y., Helmholz, H., Medina, T. P., Medina, O. P., Wiese, B., Will, O., Albaraghtheh, T., Mohamad, F. H., Hövener, J.-B., Glüer, C. C., & Römer, R. W. (2024). Inflammatory response toward a Mg-based metallic biomaterial implanted in a rat femur fracture model. Acta Biomaterialia, 185, 41–54. https://doi.org/10.1016/j.actbio.2024.06.040
  11. Huang, B., Yang, M., Kou, Y., & Jiang, B. (2024). Absorbable implants in sport medicine and arthroscopic surgery: A narrative review of recent development. Bioactive Materials, 31, 272–283. https://doi.org/10.1016/j.bioactmat.2023.08.015
  12. Sun, Y., Helmholz, H., & Willumeit-Römer, R. (2024). Peri‐implant gas accumulation in response to magnesium‐based musculoskeletal biomaterials: Reframing current evidence for preclinical research and clinical evaluation. Journal of Magnesium and Alloys, 12(1), 59–71. https://doi.org/10.1016/j.jma.2024.01.023
  13. Chen, Y., Zhang, S., Bai, J., Yang, Y., Wang, Y., Zhou, Y., Jiang, W., Wang, J., Zhu, J., Zhu, C., & Zhang, X. (2024). Magnesium-based biomaterials for coordinated tissue repair: A comprehensive overview of design strategies, advantages, and challenges. Journal of Magnesium and Alloys, 12(8), 3025–3061. https://doi.org/10.1016/j.jma.2024.05.028
  14. Cui, Y.-W., Wang, L., & Zhang, L.-C. (2024). Towards load-bearing biomedical titanium-based alloys: From essential requirements to future developments. Progress in Materials Science, 144, Article 101277. https://doi.org/10.1016/j.pmatsci.2024.101277
  15. Zhou, Y., Zhang, A., Wu, J., Guo, S., & Sun, Q. (2024). Application and Perspectives: Magnesium Materials in Bone Regeneration. ACS Biomaterials Science & Engineering, 10(6), 3514–3527. https://doi.org/10.1021/acsbiomaterials.3c01713
  16. https://doi.org/10.1186/s12891-024-07666-w
  17. Waelti, S. L., Fandak, J., Markart, S., Willems, E. P., Wildermuth, S., Fischer, T., Dietrich, T. J., Matissek, C., & Krebs, T. (2023). Prospective evaluation of ultrasound features of magnesium-based bioabsorbable screw resorption in pediatric fractures. European Radiology, 34(3), 1556–1566. https://doi.org/10.1007/s00330-023-10091-7
  18. Preobrazhenskiy, I. I., Deyneko, D. V., Titkov, V. V., Murashko, A. M., & Putlyaev, V. I. (2023). Study of magnesium-sodium double phosphates ceramic for bone treatment. Ceramics International, 49(17), 29064–29073. https://doi.org/10.1016/j.ceramint.2023.06.182
  19. Zheng, Y., Liu, X., Shen, D., Li, W., Cheng, Y., Yang, M., Kou, Y., & Jiang, B. (2023). Perceiving the connection between the bone healing process and biodegradation of biodegradable metal implants through precise bioadaptability principle. Journal of Materials Science & Technology, 147, 132–144. https://doi.org/10.1016/j.jmst.2022.12.004
  20. Nouri, A., Rohani Shirvan, A., Li, Y., & Wen, C. (2023). Biodegradable metallic suture anchors: A review. Smart Materials in Manufacturing, 1, 100005. https://doi.org/10.1016/j.smmf.2022.100005
  21. CHEN, J.-. xiu ., YANG, Y., ETIM, I. P., TAN, L.-. li ., YANG, K., MISRA, R. D. K., WANG, J.-. hua ., & SU, X.-. ping . (2023). In vitro degradation, wear property and biocompatibility of nano-Y2O3-containing micro-arc oxidation coating on ZK60 alloy. Transactions of Nonferrous Metals Society of China, 33(5), 1411–1424. https://doi.org/10.1016/s1003-6326(23)66192-8
  22. https://doi.org/10.1186/s40634-023-00663-3
  23. https://doi.org/10.3389/fbioe.2023.1227148
  24. https://doi.org/10.3390/jcm12083016
  25. https://doi.org/10.3390/jfb14060326

1–25 of 77