Published February 19, 2026 | Journal article | Version v1 | https://doi.org/10.1186/s13014-026-02807-y

Comparison of heart-sparing radiation techniques for left-sided breast cancer: DIBH combined with tangential 3D radiation vs. conventional and tangential VMAT techniques

Description

Abstract Background Adjuvant radiotherapy after breast-conserving surgery reduces local recurrence and improves survival in breast cancer. For left-sided tumors, achieving homogeneous target coverage while minimizing dose to organs at risk (OARs), particularly the heart and ipsilateral lung, remains challenging. The German S3-Guideline recommends hypofractionated whole-breast irradiation combined with deep inspiration breath hold (DIBH) to limit heart dose. This planning study compared conventional 3D conformal tangential radiotherapy (3D-FiF) and continuous-arc VMAT (cVMAT) with a novel tangential partial-arc VMAT technique (tVMAT) in left-sided breast cancer. Methods Twenty patients with left-sided breast cancer were included. For each patient, three DIBH treatment plans were generated: 3D-FiF with two opposed tangential fields and two subfields, cVMAT with a 240° double arc, and tVMAT with two partial double arcs of 40° each. Dose differences were evaluated using the Wilcoxon signed-rank test. Results Dose coverage of the clinical target volume (CTV) (D 95% ) was comparable between 3D-FiF and tVMAT, while cVMAT required a higher dose. tVMAT achieved a more homogeneous CTV dose distribution and showed significantly better conformity for both planning target volume (PTV) and CTV compared to 3D-FiF. Compared to cVMAT, tVMAT provided similar conformity and homogeneity for the PTV but lower mean doses to the heart, LAD, and left ventricle. 3D-FiF resulted in the lowest low-dose exposure of the lungs and contralateral breast, while tVMAT reduced these doses by factor 2.06 for the contralateral breast and factor 2.38 for the contralateral lung. Conclusions tVMAT proved to be a robust and reproducible irradiation technique for left-sided whole-breast irradiation in DIBH using a hypofractionated protocol. While achieving excellent dose homogeneity and conformity in the target volume, OARs – especially cardiac and contralateral structures – received significantly less low-dose exposure compared to cVMAT. Compared with 3D-FiF, tVMAT achieved more homogeneous and conformal dose distributions and was less dependent on individual planner experience. Our findings encourage the implementation of tVMAT to achieve optimal target coverage with minimal organ-at-risk exposure. Clinical trial registration Not applicable.

Additional details

Funding

Medizinische Hochschule Hannover (MHH)

Dates

Issued
February 19, 2026

References

  1. Robert Koch Institute, Association of Population-based Cancer Registries in Germany. Cancer in Germany 2019/2020. 14th ed. Berlin: Robert Koch Institute; 2024.
  2. Tyldesley, S., Foroudi, F., Barbera, L., Boyd, C., Schulze, K., Walker, H., & Mackillop, W. J. (2003). The Appropriate Rate of Breast Conserving Surgery: an Evidence-based Estimate. Clinical Oncology, 15(3), 144–155. https://doi.org/10.1053/clon.2003.0206
  3. Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trials. (2011). Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trials. The Lancet, 378(9804), 1707–1716. https://doi.org/10.1016/s0140-6736(11)61629-2
  4. Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials. (2005). Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials. The Lancet, 366(9503), 2087–2106. https://doi.org/10.1016/s0140-6736(05)67887-7
  5. Association of the Scientific Medical Societies in Germany (AWMF). S3 guideline breast cancer, long version 4.4 - June 2021. Berlin: AWMF; 2021 [cited 2025 Aug 02]. Available from: https://register.awmf.org/assets/guidelines/032-045OLI_S3_Mammakarzinom_2021-07.pdf
  6. KNÖCHELMANN, A. C., CEYLAN, N., & BREMER, M. (2021). Left-sided Breast Cancer Irradiation With Deep Inspiration Breath-hold: Changes in Heart and Lung Dose in Two Periods. In Vivo, 36(1), 314–324. https://doi.org/10.21873/invivo.12704
  7. Hall, E. J. (2006). Intensity-modulated radiation therapy, protons, and the risk of second cancers. International Journal of Radiation Oncology*Biology*Physics, 65(1), 1–7. https://doi.org/10.1016/j.ijrobp.2006.01.027
  8. Huang, Y., Gong, C., Luo, M., Yuan, X., Ding, S., Wang, X., & Zhang, Y. (2023). Comparative dosimetric and radiobiological assessment of left-sided whole breast and regional nodes with advanced radiotherapy techniques. Journal of Radiation Research, 64(4), 677–684. https://doi.org/10.1093/jrr/rrad045
  9. Fogliata, A., Seppälä, J., Reggiori, G., Lobefalo, F., Palumbo, V., De Rose, F., Franceschini, D., Scorsetti, M., & Cozzi, L. (2017). Dosimetric trade-offs in breast treatment with VMAT technique. The British Journal of Radiology, 90(1070). https://doi.org/10.1259/bjr.20160701
  10. Virén, T., Heikkilä, J., Myllyoja, K., Koskela, K., Lahtinen, T., & Seppälä, J. (2015). Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy. Radiation Oncology, 10(1). https://doi.org/10.1186/s13014-015-0392-x
  11. Vicini, F. A., Sharpe, M., Kestin, L., Martinez, A., Mitchell, C. K., Wallace, M. F., Matter, R., & Wong, J. (2002). Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 54(5), 1336–1344. https://doi.org/10.1016/s0360-3016(02)03746-x
  12. Moore, K. L. (2019). Automated Radiotherapy Treatment Planning. Seminars in Radiation Oncology, 29(3), 209–218. https://doi.org/10.1016/j.semradonc.2019.02.003
  13. Tudda, A., Castriconi, R., Placidi, L., Benecchi, G., Buono, R. C., Cagni, E., Cicchetti, A., Landoni, V., Malatesta, T., Mazzilli, A., Meffe, G., Moretti, E., Mori, M., Oliviero, C., Guidasci, G. R., Scaggion, A., Trojani, V., Vecchio, A. del ., & Fiorino, C. (2025). Multi-institutional Knowledge-Based (KB) plan prediction benchmark models for whole breast irradiation. Physica Medica, 130, 104889. https://doi.org/10.1016/j.ejmp.2024.104889
  14. Offersen, B. V., Boersma, L. J., Kirkove, C., Hol, S., Aznar, M. C., Biete Sola, A., Kirova, Y. M., Pignol, J.-P., Remouchamps, V., Verhoeven, K., Weltens, C., Arenas, M., Gabrys, D., Kopek, N., Krause, M., Lundstedt, D., Marinko, T., Montero, A., Yarnold, J., & Poortmans, P. (2015). ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer. Radiotherapy and Oncology, 114(1), 3–10. https://doi.org/10.1016/j.radonc.2014.11.030
  15. Feng, M., Moran, J. M., Koelling, T., Chughtai, A., Chan, J. L., Freedman, L., Hayman, J. A., Jagsi, R., Jolly, S., Larouere, J., Soriano, J., Marsh, R., & Pierce, L. J. (2011). Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast Cancer. International Journal of Radiation Oncology*Biology*Physics, 79(1), 10–18. https://doi.org/10.1016/j.ijrobp.2009.10.058
  16. International Commission on Radiation Units and Measurements (ICRU). Prescribing, Recording, and reporting photon beam Therapy. ICRU report 50. Bethesda, MD: ICRU; 1993.
  17. International Commission on Radiation Units and Measurements (ICRU). Prescribing, Recording, and reporting photon beam therapy (Supplement to ICRU report 50). ICRU report 62. Bethesda, MD: ICRU; 1999.
  18. International Commission on Radiation Units and Measurements (ICRU). Prescribing, Recording, and reporting Photon-Beam Intensity-Modulated radiation therapy (IMRT). ICRU report 83. Bethesda, MD: ICRU; 2010.
  19. Timmerman, R. (2022). A Story of Hypofractionation and the Table on the Wall. International Journal of Radiation Oncology*Biology*Physics, 112(1), 4–21. https://doi.org/10.1016/j.ijrobp.2021.09.027
  20. Paddick, I. (2000). A simple scoring ratio to index the conformity of radiosurgical treatment plans. Journal of Neurosurgery, 93(supplement_3), 219–222. https://doi.org/10.3171/jns.2000.93.supplement_3.0219
  21. Feuvret, L., Noël, G., Mazeron, J.-J., & Bey, P. (2006). Conformity index: A review. International Journal of Radiation Oncology*Biology*Physics, 64(2), 333–342. https://doi.org/10.1016/j.ijrobp.2005.09.028
  22. Zhao, H., He, M., Cheng, G., Han, D., Wu, N., Shi, D., Zhao, Z., & Jin, J. (2015). A comparative dosimetric study of left sided breast cancer after breast-conserving surgery treated with VMAT and IMRT. Radiation Oncology, 10(1). https://doi.org/10.1186/s13014-015-0531-4
  23. Munshi, A., Sarkar, B., Anbazhagan, S., Giri, U. K., Kaur, H., Jassal, K., Ganesh, T., & Kalyan Mohanti, B. (2017). Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients. Australasian Physical & Engineering Sciences in Medicine, 40(3), 729–736. https://doi.org/10.1007/s13246-017-0558-y
  24. Yu, P.-C., Wu, C.-J., Tsai, Y.-L., Shaw, S., Sung, S.-Y., Lui, L. T., & Nien, H.-H. (2018). Dosimetric analysis of tangent-based volumetric modulated arc therapy with deep inspiration breath-hold technique for left breast cancer patients. Radiation Oncology, 13(1). https://doi.org/10.1186/s13014-018-1170-3
  25. Karpf, D., Sakka, M., Metzger, M., & Grabenbauer, G. G. (2019). Left breast irradiation with tangential intensity modulated radiotherapy (t-IMRT) versus tangential volumetric modulated arc therapy (t-VMAT): trade-offs between secondary cancer induction risk and optimal target coverage. Radiation Oncology, 14(1). https://doi.org/10.1186/s13014-019-1363-4

1–25 of 36