Sonographic guidance for electron boost planning after breast‐conserving surgery
Authors/Creators
Description
AbstractPurposeThis study was conducted to determine the feasibility of using sonography for electron boost planning in breast cancer treatment and to define the factors that influence the accuracy and reproducibility of this technique.Patients and MethodsSeventy‐seven patients underwent 102 sonographic examinations after breast‐conserving surgery and before and after radiotherapy. The size of the electron boost field was defined by measuring the postoperative cavity. Reproducibility of the sonographic findings was investigated in 25 of the patients who were examined before and after radiotherapy (at a total dose of 46–50.4 Gy). Depth (distance from the skin surface to the posterior aspect of the postoperative cavity) was measured, and sonographic appearance of the postoperative cavity was evaluated. Type of surgical procedure, time elapsed since surgery, use of systemic therapy, menopausal status, breast size, and radiation dose were investigated for their influence on sonographic appearance and visualization of the postoperative cavity.ResultsThe postoperative cavity was well visualized in 78% of patients and visualized with some difficulty in 22%. In all but 5 patients, it was hypoechoic and inhomogeneous. The mean depth of the postoperative cavity after radiotherapy was 27 ± 4 mm. Smaller breast (p < 0.001) and younger age (p < 0.05) were associated with decreased visibility of the postoperative cavity. Sonographic appearance was the same before and after radiotherapy, but the mean difference in postoperative cavity depth between the 2 measurements was 2 mm (range, 0–4 mm). In 43/77 (56%) of the patients, changes in electron energy or in field size were required after sonographic measurement.ConclusionSonography is a useful and reproducible means of electron boost planning, helping to avoid underdosage of the postoperative cavity and overdosage of normal tissue. © 2004 Wiley Periodicals, Inc. J Clin Ultrasound 32:333–337, 2004
Additional details
Identifiers
- OpenAlex
- W1988465128
- PMID
- 15293299
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/jcu.20050
Dates
- Issued
-
July 29, 2004
References
- Fowble, B., Solin, L. J., Schultz, D. J., Rubenstein, J., & Goodman, R. L. (1990). Breast recurrence following conservative surgery and radiation: patterns of failure, prognosis, and pathologic findings from mastectomy specimens with implications for treatment. International Journal of Radiation Oncology*Biology*Physics, 19(4), 833–842. https://doi.org/10.1016/0360-3016(90)90002-2
- Gilligan, D., Hendry, J. A., & Yarnold, J. R. (1994). The use of ultrasound to measure breast thickness to select electron energies for breast boost radiotherapy. Radiotherapy and Oncology, 32(3), 265–267. https://doi.org/10.1016/0167-8140(94)90026-4
- Price, P., Walsh, G., McKinna, A. J., Ashley, S., & Yarnold, J. R. (1988). Patterns of breast relapse after local excision ± radiotherapy for early stage breast cancer. Radiotherapy and Oncology, 13(1), 53–60. https://doi.org/10.1016/0167-8140(88)90298-8
- Recht, A., & Harris, J. R. (1991). To boost or not to boost, and how to do it. International Journal of Radiation Oncology*Biology*Physics, 20(1), 177–178. https://doi.org/10.1016/0360-3016(91)90155-w
- A model for primary and secondary metastasis in breast cancer and the clinical consequences
- Bartelink, H., Garavaglia, G., Johansson, K.-A., Mijnheer, B. J., Van den Bogaert, W., van Tienhoven, G., & Yarnold, J. (1991). Quality assurance in conservative treatment of early breast cancer. Radiotherapy and Oncology, 22(4), 323–326. https://doi.org/10.1016/0167-8140(91)90172-d
- Sedlmayer, F., Rahim, H. B. K., Dieter Kogelnik, H., Menzel, C., Merz, F., Deutschmann, H., & Kranzinger, M. (1996). Quality assurance in breast cancer brachytherapy: Geographic miss in the interstitial boost treatment of the tumor bed. International Journal of Radiation Oncology*Biology*Physics, 34(5), 1133–1139. https://doi.org/10.1016/0360-3016(95)02176-0
- Vrieling, C., Collette, L., Fourquet, A., Hoogenraad, W. J., Horiot, J.-C., Jager, J. J., Pierart, M., Poortmans, P. M., Struikmans, H., Van der Hulst, M., Van der Schueren, E., & Bartelink, H. (1999). The influence of the boost in breast-conserving therapy on cosmetic outcome in the eortc "boost versus no boost" trial. International Journal of Radiation Oncology*Biology*Physics, 45(3), 677–685. https://doi.org/10.1016/s0360-3016(99)00211-4
- Harrington, K. J., Harrison, M., Bayle, P., Evans, K., Dunn, P. A., Lambert, H. E., Saidan, Z., Lynn, J., & Stewart, J. S. W. (1996). Surgical clips in planning the electron boost in breast cancer: A qualitative and quantitative evaluation. International Journal of Radiation Oncology*Biology*Physics, 34(3), 579–584. https://doi.org/10.1016/0360-3016(95)02090-x
- Leonard, C., Harlow, C. L., Coffin, C., Dross, J., Norton, L., & Kinzie, J. (1993). Use of ultrasound to guide radiation boost planning following lumpectomy for carcinoma of the breast. International Journal of Radiation Oncology*Biology*Physics, 27(5), 1193–1197. https://doi.org/10.1016/0360-3016(93)90543-5
- Messer, P. M., Kirikuta, I. C., Bratengeier, K., & Flentje, M. (1997). CT planning of boost irradiation in radiotherapy of breast cancer after conservative surgery. Radiotherapy and Oncology, 42(3), 239–243. https://doi.org/10.1016/s0167-8140(96)01891-9
- Clarke, D. H., G. Lê, M., Sarrazin, D., Lacombe, M.-J., Fontaine, F., Travagli, J.-P., May-Levin, F., Contesso, G., & Arriagada, R. (1985). Analysis of local-regional relapses in patients with early breast cancers treated by excision and radiotherapy: experience of the Institut Gustave-Roussy. International Journal of Radiation Oncology*Biology*Physics, 11(1), 137–145. https://doi.org/10.1016/0360-3016(85)90372-4
- Kurtz, J. M. (2001). Which Patients Don't Need a Tumor-Bed Boost after Whole-Breast Radiotherapy?. Strahlentherapie Und Onkologie, 177(1), 33–36. https://doi.org/10.1007/pl00002355
- Machtay, M., Lanciano, R., Hoffman, J., & Hanks, G. E. (1994). Inaccuracies in using the lumpectomy scar for planning electron boosts in primary breast carcinoma. International Journal of Radiation Oncology*Biology*Physics, 30(1), 43–48. https://doi.org/10.1016/0360-3016(94)90517-7
- Smitt, M. C., Birdwell, R. L., & Goffinet, D. R. (2001). Breast Electron Boost Planning: Comparison of CT and US. Radiology, 219(1), 203–206. https://doi.org/10.1148/radiology.219.1.r01ap34203
- Bedwinek, J. (1993). Breast conserving surgery and irradiation: The importance of demarcating the excision cavity with surgical clips. International Journal of Radiation Oncology*Biology*Physics, 26(4), 675–679. https://doi.org/10.1016/0360-3016(93)90287-6
- Fein, D. A., Fowble, B. L., Hanlon, A. L., Hoffman, J. P., Sigurdson, E. R., & Eisenberg, B. L. (1996). Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast-conserving surgery and irradiation?. International Journal of Radiation Oncology*Biology*Physics, 34(5), 1009–1017. https://doi.org/10.1016/0360-3016(95)02258-9
- Regine, W. F., Ayyangar, K. M., Komarnicky, L. T., Bhandare, N., & Mansfield, C. M. (1991). Computer-CT planning of the electron boost om definitive breast irradiation. International Journal of Radiation Oncology*Biology*Physics, 20(1), 121–125. https://doi.org/10.1016/0360-3016(91)90147-v
Citations
- Gardner, S. J., Kim, J., & Chetty, I. J. (2019). Modern Radiation Therapy Planning and Delivery. Hematology/Oncology Clinics of North America, 33(6), 947–962. https://doi.org/10.1016/j.hoc.2019.08.005
- Fontanarosa, D., van der Meer, S., Bamber, J., Harris, E., O’Shea, T., & Verhaegen, F. (2015). Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management. Physics in Medicine & Biology, 60(3), R77–R114. https://doi.org/10.1088/0031-9155/60/3/r77
- De Los Santos, J., Popple, R., Agazaryan, N., Bayouth, J. E., Bissonnette, J.-P., Bucci, M. K., Dieterich, S., Dong, L., Forster, K. M., Indelicato, D., Langen, K., Lehmann, J., Mayr, N., Parsai, I., Salter, W., Tomblyn, M., Yuh, W. T. C., & Chetty, I. J. (2013). Image Guided Radiation Therapy (IGRT) Technologies for Radiation Therapy Localization and Delivery. International Journal of Radiation Oncology*Biology*Physics, 87(1), 33–45. https://doi.org/10.1016/j.ijrobp.2013.02.021
- Electron therapy. (2012). Electron therapy. In Biomedical Physics in Radiotherapy for Cancer (pp. 285–307). CSIRO Publishing. https://doi.org/10.1071/9780643103306.ch12
- Fraser, D. J., Wong, P., Sultanem, K., & Verhaegen, F. (2010). Dosimetric evolution of the breast electron boost target using 3D ultrasound imaging. Radiotherapy and Oncology, 96(2), 185–191. https://doi.org/10.1016/j.radonc.2010.05.017