Guidelines for Orbital Defect Assessment and Patient-Specific Implant Design: Introducing OA2 (Orbital Assessment Algorithm)
Authors/Creators
-
1.
Medizinische Hochschule Hannover
- 2. Division of Plastic and Reconstructive Surgery, Shock Trauma Center, Baltimore, MD, USA
-
3.
Victoria Hospital
Description
Study Design This study presents a review of the evolutionary development in reconstructive orbital surgery over the past 3 decades. Additionally, it proposes the Orbital Assessment Algorithm (OA2) to enhance decision-making for intraorbital reconstruction of post-traumatic orbital deformities. Objective The objective of this paper is to provide insights into modern post-traumatic orbital reconstruction from a surgeon's perspective, with a specific focus on adult patients. It aims to highlight the advancements in computer-aided design and manufacturing techniques, particularly in the field of reconstructive orbital surgery, and to introduce the OA2 as a tool for improved decision-making in this context. Methods The study conducts a comprehensive review of the evolution of reconstructive orbital surgery, focusing on the integration of 3D technology into surgical practices. It also outlines the development and rationale behind the proposed OA2, emphasizing its potential to enhance the accuracy and efficacy of intraorbital reconstruction procedures for post-traumatic deformities. Results The review demonstrates the significant progress made in reconstructive orbital surgery, particularly in leveraging 3D technology for virtual modeling, navigation, and the design and manufacturing of patient-specific implants. The introduction of the OA2 provides a structured approach to assessing and addressing post-traumatic orbital deformities, offering potential benefits in decision-making and surgical outcomes. Conclusions In conclusion, this paper underscores the pivotal role of computer-aided design and manufacturing in advancing reconstructive orbital surgery. It highlights the importance of integrating innovative design concepts into implant manufacturing processes and emphasizes the potential of the OA2 to guide surgeons in the management of post-traumatic orbital deformities, ultimately contributing to improved patient outcomes.
Additional details
Identifiers
- OpenAlex
- W4403732342
- PMID
- 39544314
- URL
- https://www.mdpi.com/1943-3883/17/4/47
Dates
- Issued
-
October 24, 2024
References
- Manson, P. N. (2004). The Orbit After Converse: Seeing What Is Not There. Journal of Craniofacial Surgery, 15(3), 363–367. https://doi.org/10.1097/00001665-200405000-00003
- Three-Dimensional CT Diagnosis of Maxillofacial Trauma. (1994). Three-Dimensional CT Diagnosis of Maxillofacial Trauma. New England Journal of Medicine, 330(1), 69–69. https://doi.org/10.1056/nejm199401063300118
- Kolk, A., Pautke, C., Schott, V., Ventrella, E., Wiener, E., Ploder, O., Horch, H. H., & Neff, A. (2007). Secondary Post-Traumatic Enophthalmos: High-Resolution Magnetic Resonance Imaging Compared With Multislice Computed Tomography in Postoperative Orbital Volume Measurement. Journal of Oral and Maxillofacial Surgery, 65(10), 1926–1934. https://doi.org/10.1016/j.joms.2006.06.269
- Kokemueller, H., Zizelmann, C., Tavassol, F., Paling, T., & Gellrich, N.-C. (2008). A Comprehensive Approach to Objective Quantification of Orbital Dimensions. Journal of Oral and Maxillofacial Surgery, 66(2), 401–407. https://doi.org/10.1016/j.joms.2006.05.062
- Zimmerer, R. M., Ellis, E., Aniceto, G. S., Schramm, A., Wagner, M. E. H., Grant, M. P., Cornelius, C.-P., Strong, E. B., Rana, M., Chye, L. T., Calle, A. R., Wilde, F., Perez, D., Tavassol, F., Bittermann, G., Mahoney, N. R., Alamillos, M. R., Bašić, J., Dittmann, J., … Gellrich, N.-C. (2016). A prospective multicenter study to compare the precision of posttraumatic internal orbital reconstruction with standard preformed and individualized orbital implants. Journal of Cranio-Maxillofacial Surgery, 44(9), 1485–1497. https://doi.org/10.1016/j.jcms.2016.07.014
- Manson, P. N., Grivas, A., Rosenbaum, A., Vannier, M., Zinreich, J., & Iliff, N. (1986). Studies on Enophthalmos: II. The Measurement of Orbital Injuries and Their Treatment by Quantitative Computed Tomography. Plastic and Reconstructive Surgery, 77(2), 203–214. https://doi.org/10.1097/00006534-198602000-00005
- Manson, P. N., Ruas, E. J., & Iliff, N. T. (1987). Deep Orbital Reconstruction for Correction of Post-traumatic Enophthalmos. Clinics in Plastic Surgery, 14(1), 113–121. https://doi.org/10.1016/s0094-1298(20)30702-1
- Callahan, A. B., Campbell, A. A., Petris, C., & Kazim, M. (2017). Low-Cost 3D Printing Orbital Implant Templates in Secondary Orbital Reconstructions. Ophthalmic Plastic & Reconstructive Surgery, 33(5), 376–380. https://doi.org/10.1097/iop.0000000000000884
- Essig, H., Dressel, L., Rana, M., Rana, M., Kokemueller, H., Ruecker, M., & Gellrich, N.-C. (2013). Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: a retrospective study. Head & Face Medicine, 9(1). https://doi.org/10.1186/1746-160x-9-18
- Markiewicz, M. R., Dierks, E. J., & Bell, R. B. (2012). Does intraoperative navigation restore orbital dimensions in traumatic and post-ablative defects?. Journal of Cranio-Maxillofacial Surgery, 40(2), 142–148. https://doi.org/10.1016/j.jcms.2011.03.008
- Metzger, M. C., Hohlweg-Majert, B., Schön, R., Teschner, M., Gellrich, N.-C., Schmelzeisen, R., & Gutwald, R. (2007). Verification of clinical precision after computer-aided reconstruction in craniomaxillofacial surgery. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, 104(4), e1–e10. https://doi.org/10.1016/j.tripleo.2007.04.015
- Kawamoto, H. K. (2011). Secondary Correction of Traumatic “Dislocation Orbito-Nasale” Fractures. Annals of Plastic Surgery, 67(6), S25–S30. https://doi.org/10.1097/sap.0b013e31821835f5
- Ciprandi, M. T. O., Primo, B. T., Gassen, H. T., Closs, L. Q., Hernandez, P. A. G., & Silva, A. N. (2012). Calcium Phosphate Cement in Orbital Reconstructions. Journal of Craniofacial Surgery, 23(1), 145–148. https://doi.org/10.1097/scs.0b013e3182413d31
- Gruss, J. S. (1986). Complex Nasoethmoid–Orbital and Midfacial Fractures: Role of Craniofacial Surgical Techniques and Immediate Bone Grafting. Annals of Plastic Surgery, 17(5), 377–390. https://doi.org/10.1097/00000637-198611000-00005
- Klein, M., & Glatzer, C. (2006). Individual CAD/CAM Fabricated Glass-Bioceramic Implants in Reconstructive Surgery of the Bony Orbital Floor. Plastic and Reconstructive Surgery, 117(2), 565–570. https://doi.org/10.1097/01.prs.0000200770.83864.bc
- Nkenke, E. (2011). Secondary Reconstruction of Posttraumatic Enophthalmos: Prefabricated Implants vs Titanium Mesh. Archives of Facial Plastic Surgery, 13(4), 271. https://doi.org/10.1001/archfacial.2011.41
- Schubert, W., Gear, A. J. L., Lee, C., Hilger, P. A., Haus, E., Migliori, M. R., Mann, D. A., & Benjamin, C. I. (2002). Incorporation of Titanium Mesh in Orbital and Midface Reconstruction. Plastic and Reconstructive Surgery, 110(4), 1022–1030. https://doi.org/10.1097/01.prs.0000021307.23118.e7
- Bourry, M., Hardouin, J., Fauvel, F., Corre, P., Lebranchu, P., & Bertin, H. (2020). Clinical evaluation of the efficacy of materials used for primary reconstruction of orbital floor defects: Meta‐analysis. Head & Neck, 43(2), 679–690. https://doi.org/10.1002/hed.26518
- Kotecha, S., Ferro, A., Harrison, P., & Fan, K. (2022). Orbital reconstruction: a systematic review and meta-analysis evaluating the role of patient-specific implants. Oral and Maxillofacial Surgery, 27(2), 213–226. https://doi.org/10.1007/s10006-022-01074-x
- Taxis, J., Ungerboeck, L., Motel, C., Eckert, A. W., Platz Batista da Silva, N., Nieberle, F., Ludwig, N., Meier, J. K., Ettl, T., Reichert, T. E., & Spoerl, S. (2023). Thin PDS Foils Represent an Equally Favorable Restorative Material for Orbital Floor Fractures Compared to Titanium Meshes. Tomography, 9(4), 1515–1525. https://doi.org/10.3390/tomography9040121
- Ali, K., Schultz, K., Marx, D., Buchanan, E., & Hollier, L. (2017). Secondary Repair of Posttraumatic Enophthalmos and Extraocular Movement Disorders. Facial Plastic Surgery, 33(06), 606–612. https://doi.org/10.1055/s-0037-1608781
- Paskert, J. P., Manson, P. N., & Iliff, N. T. (1988). Nasoethmoidal and Orbital Fractures. Clinics in Plastic Surgery, 15(2), 209–223. https://doi.org/10.1016/s0094-1298(20)31439-5
- Wagner, M. E. H., Gellrich, N.-C., Friese, K.-I., Becker, M., Wolter, F.-E., Lichtenstein, J. T., Stoetzer, M., Rana, M., & Essig, H. (2015). Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts. International Journal of Computer Assisted Radiology and Surgery, 11(1), 1–9. https://doi.org/10.1007/s11548-015-1228-8
- Schreurs, R., Wilde, F., Schramm, A., & Gellrich, N.-C. (2021). Intraoperative Feedback and Quality Control in Orbital Reconstruction. Atlas of the Oral and Maxillofacial Surgery Clinics, 29(1), 97–108. https://doi.org/10.1016/j.cxom.2020.11.006
- Schramm, A., & Wilde, F. (2014). Intraoperative Imaging in Orbital and Midface Reconstruction. Facial Plastic Surgery, 30(05), 545–553. https://doi.org/10.1055/s-0034-1393700
1–25 of 46
Citations
- Scheurer, M., Schulze, J., Sakkas, A., Kasper, R., Greber, L., Rana, M., Wilde, F., Schramm, A., & Ebeling, M. (2026). Technical Note - A patient-specific implant for orbital wall reconstruction with infraorbital rim extension: Accuracy and proof-of-principle evaluation of an “one-fit-only” design. Journal of Cranio-Maxillofacial Surgery, 54(12), 109917. https://doi.org/10.1016/j.jcms.2026.109917
- https://doi.org/10.1186/s13005-025-00582-x
- https://doi.org/10.1186/s12903-025-07082-z
- https://doi.org/10.3390/cmtr18010015
- https://doi.org/10.7759/cureus.90382