The History, Challenges and the Future of Biodegradable Metal Implants
Description
New interest in magnesium alloys as temporary biomaterials was reborn in the recent years. Especially metals based on physiological trace elements seem to be promising as an alternative to current biodegradable implant materials in cardiovascular and musculoskeletal applications. First clinical reports can be dated back before 1900. Magnesium alloys were used by surgeons of different clinical background in cardiovascular, neural, skin, general and musculoskeletal surgery. All patients have benefited from the treatment with magnesium alloys, although rapid corrosion caused sometimes painless subcutaneous gas cavities. These reports encouraged researchers to study and invent new magnesium alloys which aim to provide more uniform and slow corrosion rates. The most challenging part was to analyze the corrosion of implanted magnesium alloys in-vivo, since the magnesium alloys interlock with the surrounding tissue during corrosion. Therefore, the implanted samples could not be retrieved without damaging the fragile implant-tissue interface. Synchrotron-radiation based microtomography (SRµCT) was introduced as a solution to this challenge. SRµCT enables to measure non-destructively the in-vivo corrosion rates of magnesium alloys as well as their corrosion morphology. Based on these data, it was concluded that suitable magnesium implants should provide small grains, which are distributed very homogenously and should be produced with highest purity. The future of biodegradable magnesium alloys might be directed towards implant areas where high ductility, maximal tensile strength as well as high compression strength is needed and the properties of current biodegradable implant-materials are exceeded by the properties of magnesium alloys.
Additional details
Identifiers
- OpenAlex
- W2071079265
- URL
- https://www.scientific.net/AMR.95.3
Dates
- Issued
-
January 2010
Citations
- Chandra, G., & Pandey, A. (2022). Preparation Strategies for Mg-Alloys for Biodegradable Orthopaedic Implants and Other Biomedical Applications: A Review. IRBM, 43(3), 229–249. https://doi.org/10.1016/j.irbm.2020.06.003
- Prokoshkin, S., Pustov, Y., Zhukova, Y., Kadirov, P., Dubinskiy, S., Sheremetyev, V., & Karavaeva, M. (2021). Effect of Thermomechanical Treatment on Functional Properties of Biodegradable Fe-30Mn-5Si Shape Memory Alloy. Metallurgical and Materials Transactions A, 52(5), 2024–2032. https://doi.org/10.1007/s11661-021-06217-5
- Chandra, G., & Pandey, A. (2021). Design approaches and challenges for biodegradable bone implants: a review. Expert Review of Medical Devices, 18(7), 629–647. https://doi.org/10.1080/17434440.2021.1935875
- Van der Biest, O., Gil-Santos, A., Hort, N., Schmid-Fetzer, R., & Moelans, N. (2018). Study on Mg–Si–Sr Ternary Alloys for Biomedical Applications. In The Minerals, Metals & Materials Series (pp. 413–424). Springer International Publishing. https://doi.org/10.1007/978-3-319-72332-7_64
- Bakhsheshi-Rad, H. R., Hamzah, E., Tok, H. Y., Kasiri-Asgarani, M., Jabbarzare, S., & Medraj, M. (2017). Microstructure, In Vitro Corrosion Behavior and Cytotoxicity of Biodegradable Mg-Ca-Zn and Mg-Ca-Zn-Bi Alloys. Journal of Materials Engineering and Performance, 26(2), 653–666. https://doi.org/10.1007/s11665-016-2499-0
- https://doi.org/10.1557/jmr.2017.419
- Rahim, M. I., Weizbauer, A., Evertz, F., Hoffmann, A., Rohde, M., Glasmacher, B., Windhagen, H., Gross, G., Seitz, J., & Mueller, P. P. (2016). Differential magnesium implant corrosion coat formation and contribution to bone bonding. Journal of Biomedical Materials Research Part A, 105(3), 697–709. https://doi.org/10.1002/jbm.a.35943
- Gil-Santos, A., Moelans, N., Hort, N., & Van der Biest, O. (2016). Identification and description of intermetallic compounds in Mg–Si–Sr cast and heat-treated alloys. Journal of Alloys and Compounds, 669, 123–133. https://doi.org/10.1016/j.jallcom.2016.01.221
- Schaffer, J. E., Nauman, E. A., & Stanciu, L. A. (2013). Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility. Acta Biomaterialia, 9(10), 8574–8584. https://doi.org/10.1016/j.actbio.2012.07.043
- Doepke, A., Kuhlmann, J., Guo, X., Voorhees, R. T., & Heineman, W. R. (2013). A system for characterizing Mg corrosion in aqueous solutions using electrochemical sensors and impedance spectroscopy. Acta Biomaterialia, 9(11), 9211–9219. https://doi.org/10.1016/j.actbio.2013.07.011
- https://doi.org/10.1680/emr.12.00020
- Das, D., Zhang, Z., Winkler, T., Mour, M., Günter, C. I., Morlock, M. M., Machens, H.-G., & Schilling, A. F. (2011). Bioresorption and Degradation of Biomaterials. In Advances in Biochemical Engineering/Biotechnology (pp. 317–333). Springer Berlin Heidelberg. https://doi.org/10.1007/10_2011_119
- Gupta, N., Luong, D. D., & Rohatgi, P. K. (2011). A method for intermediate strain rate compression testing and study of compressive failure mechanism of Mg-Al-Zn alloy. Journal of Applied Physics, 109(10). https://doi.org/10.1063/1.3590155