Published January 5, 2023 | Journal article | Version v1 | https://doi.org/10.3390/bioengineering10010072

Biohybrid lung Development: Towards Complete Endothelialization of an Assembled Extracorporeal Membrane Oxygenator

  • 1. Department for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30625 Hannover, Germany
  • 2. Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Stadtfelddamm 34, 30625 Hannover, Germany
  • 3. ROR icon None

Description

Towards the establishment of a long-term lung-assist device to be used both as a bridge and as an alternative to lung transplantation according to final destination therapy, we develop the biohybrid lung (BHL) on the technical basis of contemporary extracorporeal membrane oxygenation (ECMO). Here, to overcome the significant drawbacks of ECMO, in particular the missing hemocompatibility of the artificial surfaces, all blood-contacting areas need to be endothelialized sufficiently. In continuation of our recent accomplishments, demonstrating the feasibility of establishing a physiological acting endothelial cell (EC) monolayer on the hollow fiber membranes (HFMs) of the ECMO in vitro, the next step towards BHL translation is the endothelialization of the complete oxygenator, consisting of HFMs and the surrounding housing. Therefore, we assessed EC seeding inside our model oxygenator (MOx), which simulated the conditions in the assembled HFM oxygenators in order to identify the most important factors influencing efficient endothelialization, such as cell seeding density, cell distribution, incubation time and culture medium consumption. Overall, upon adjusting the concentration of infused ECs to 15.2 × 104/cm2 and ensuring optimal dispersion of cells in the MOx, viable and confluent EC monolayers formed on all relevant surfaces within 24 h, even though they comprised different polymers, i.e., the fibronectin-coated HFMs and the polysulfone MOx housing. Periodic medium change ensured monolayer survival and negligible apoptosis rates comparable to the reference within the assembled system. By means of these results, revealing essential implications for BHL development, their clinical translation is coming one step closer to reality.

Additional details

Funding

German Centre for Lung Research (DZL)
82DZL00201
German Centre for Lung Research (DZL)
347346497
German Centre for Lung Research (DZL)
447746988
German Centre for Lung Research (DZL)
347368182
German Centre for Lung Research (DZL)
ZN3440
German Research Foundation
82DZL00201
German Research Foundation
347346497
German Research Foundation
447746988
German Research Foundation
347368182
German Research Foundation
ZN3440
Federal State of Lower Saxony
82DZL00201
Federal State of Lower Saxony
347346497
Federal State of Lower Saxony
447746988
Federal State of Lower Saxony
347368182
Federal State of Lower Saxony
ZN3440
ROR icon Deutsche Forschungsgemeinschaft
DFGSPP2014

Dates

Issued
January 5, 2023

References

  1. (2022, August 24). ISHLT: The International Society for Heart & Lung Transplantation—TTX Registry Slides. Available online: https://ishlt.org/research-data/registries/ttx-registry/ttx-registry-slides
  2. (2022, August 23). Heart, Available online: https://srtr.transplant.hrsa.gov/annual_reports/2020/Lung.aspx
  3. Smits, J. M., Nossent, G., Evrard, P., Lang, G., Knoop, C., Kwakkel-van Erp, J. M., Langer, F., Schramm, R., van de Graaf, E., Vos, R., Verleden, G., Rondelet, B., Hoefer, D., Hoek, R., Hoetzenecker, K., Deuse, T., Strelniece, A., Green, D., de Vries, E., … Gottlieb, J. (2018). Lung allocation score: the Eurotransplant model versus the revised US model - a cross-sectional study. Transplant International, 31(8), 930–937. https://doi.org/10.1111/tri.13262
  4. Gottlieb, J. (2017). Lung allocation. Journal of Thoracic Disease, 9(8), 2670–2674. https://doi.org/10.21037/jtd.2017.07.83
  5. (2022, August 23). The to10 Causes of Death. Available online: https://www.who.int/news-room/fact-sheets/detail/the-top-10-causes-of-death
  6. Tonna, J. E., Abrams, D., Brodie, D., Greenwood, J. C., RUBIO Mateo-Sidron, J. A., Usman, A., & Fan, E. (2021). Management of Adult Patients Supported with Venovenous Extracorporeal Membrane Oxygenation (VV ECMO): Guideline from the Extracorporeal Life Support Organization (ELSO). ASAIO Journal, 67(6), 601–610. https://doi.org/10.1097/mat.0000000000001432
  7. Biran, R., & Pond, D. (2017). Heparin coatings for improving blood compatibility of medical devices. Advanced Drug Delivery Reviews, 112, 12–23. https://doi.org/10.1016/j.addr.2016.12.002
  8. Lehle, K., Philipp, A., Gleich, O., Holzamer, A., Müller, T., Bein, T., & Schmid, C. (2008). Efficiency in Extracorporeal Membrane Oxygenation—Cellular Deposits on Polymethypentene Membranes Increase Resistance to Blood Flow and Reduce Gas Exchange Capacity. ASAIO Journal, 54(6), 612–617. https://doi.org/10.1097/mat.0b013e318186a807
  9. Callaghan, S., Cai, T., McCafferty, C., Van Den Helm, S., Horton, S., MacLaren, G., Monagle, P., & Ignjatovic, V. (2020). Adsorption of Blood Components to Extracorporeal Membrane Oxygenation (ECMO) Surfaces in Humans: A Systematic Review. Journal of Clinical Medicine, 9(10), 3272. https://doi.org/10.3390/jcm9103272
  10. (2022, December 14). Rapid Activation of the Alternative Pathway of Complement by: ASAIO Journal. Available online: https://journals.lww.com/asaiojournal/Abstract/1999/01000/Rapid_Activation_of_the_Alternative_Pathway_of.25.aspx
  11. Zimpfer, D., Fiane, A. E., Larbalestier, R., Tsui, S., Jansz, P., Simon, A., Schueler, S., Strueber, M., & Schmitto, J. D. (2020). Long-Term Survival of Patients With Advanced Heart Failure Receiving an Left Ventricular Assist Device Intended as a Bridge to Transplantation. Circulation: Heart Failure, 13(3). https://doi.org/10.1161/circheartfailure.119.006252
  12. McGuigan, A. P., & Sefton, M. V. (2007). The influence of biomaterials on endothelial cell thrombogenicity. Biomaterials, 28(16), 2547–2571. https://doi.org/10.1016/j.biomaterials.2007.01.039
  13. Matsuzaki, Y., John, K., Shoji, T., & Shinoka, T. (2019). The Evolution of Tissue Engineered Vascular Graft Technologies: From Preclinical Trials to Advancing Patient Care. Applied Sciences, 9(7), 1274. https://doi.org/10.3390/app9071274
  14. Koenneker, S., Teebken, O. E., Bonehie, M., Pflaum, M., Jockenhoevel, S., Haverich, A., & Wilhelmi, M. H. (2010). A Biological Alternative to Alloplastic Grafts in Dialysis Therapy: Evaluation of an Autologised Bioartificial Haemodialysis Shunt Vessel in a Sheep Model. European Journal of Vascular and Endovascular Surgery, 40(6), 810–816. https://doi.org/10.1016/j.ejvs.2010.04.023
  15. Dietrich, M., Finocchiaro, N., Olszweski, S., Arens, J., Schmitz-Rode, T., Sachweh, J., Jockenhoevel, S., Cornelissen, C. G., & Soncini, M. (2015). ENDOXY - Development of a Biomimetic Oxygenator-Test-Device. PLOS ONE, 10(12), e0142961. https://doi.org/10.1371/journal.pone.0142961
  16. Polk, A. A., Maul, T. M., McKeel, D. T., Snyder, T. A., Lehocky, C. A., Pitt, B., Stolz, D. B., Federspiel, W. J., & Wagner, W. R. (2010). A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers. Biotechnology and Bioengineering, 106(3), 490–500. https://doi.org/10.1002/bit.22675
  17. Klein, S., Hesselmann, F., Djeljadini, S., Berger, T., Thiebes, A. L., Schmitz-Rode, T., Jockenhoevel, S., & Cornelissen, C. G. (2019). EndOxy: Dynamic Long-Term Evaluation of Endothelialized Gas Exchange Membranes for a Biohybrid Lung. Annals of Biomedical Engineering, 48(2), 747–756. https://doi.org/10.1007/s10439-019-02401-2
  18. Pflaum, M., Kühn-Kauffeldt, M., Schmeckebier, S., Dipresa, D., Chauhan, K., Wiegmann, B., Haug, R. J., Schein, J., Haverich, A., & Korossis, S. (2017). Endothelialization and characterization of titanium dioxide-coated gas-exchange membranes for application in the bioartificial lung. Acta Biomaterialia, 50, 510–521. https://doi.org/10.1016/j.actbio.2016.12.017
  19. Takagi, M., Shiwaku, K., Inoue, T., Shirakawa, Y., Sawa, Y., Matsuda, H., & Yoshida, T. (2003). Hydrodynamically stable adhesion of endothelial cells onto a polypropylene hollow fiber membrane by modification with adhesive protein. Journal of Artificial Organs, 6(3), 222–226. https://doi.org/10.1007/s10047-003-0218-8
  20. Zwirner, U., Höffler, K., Pflaum, M., Korossis, S., Haverich, A., & Wiegmann, B. (2018). Identifying an optimal seeding protocol and endothelial cell substrate for biohybrid lung development. Journal of Tissue Engineering and Regenerative Medicine, 12(12), 2319–2330. https://doi.org/10.1002/term.2764
  21. Möller, L., Hess, C., Paleček, J., Su, Y., Haverich, A., Kirschning, A., & Dräger, G. (2013). Towards a biocompatible artificial lung: Covalent functionalization of poly(4-methylpent-1-ene) (TPX) with cRGD pentapeptide. Beilstein Journal of Organic Chemistry, 9, 270–277. https://doi.org/10.3762/bjoc.9.33
  22. Pflaum, M., Jurmann, S., Katsirntaki, K., Mälzer, M., Haverich, A., & Wiegmann, B. (2021). Towards Biohybrid Lung Development—Fibronectin-Coating Bestows Hemocompatibility of Gas Exchange Hollow Fiber Membranes by Improving Flow-Resistant Endothelialization. Membranes, 12(1), 35. https://doi.org/10.3390/membranes12010035
  23. Hess, C., Wiegmann, B., Maurer, A. N., Fischer, P., Möller, L., Martin, U., Hilfiker, A., Haverich, A., & Fischer, S. (2010). Reduced Thrombocyte Adhesion to Endothelialized Poly 4-Methyl-1-Pentene Gas Exchange Membranes—A First Step Toward Bioartificial Lung Development. Tissue Engineering Part A, 16(10), 3043–3053. https://doi.org/10.1089/ten.tea.2010.0131
  24. Pflaum, M., Dahlmann, J., Engels, L., Naghilouy-Hidaji, H., Adam, D., Zöllner, J., Otto, A., Schmeckebier, S., Martin, U., Haverich, A., Olmer, R., & Wiegmann, B. (2021). Towards Biohybrid Lung: Induced Pluripotent Stem Cell Derived Endothelial Cells as Clinically Relevant Cell Source for Biologization. Micromachines, 12(8), 981. https://doi.org/10.3390/mi12080981
  25. Wiegmann, B., Figueiredo, C., Gras, C., Pflaum, M., Schmeckebier, S., Korossis, S., Haverich, A., & Blasczyk, R. (2014). Prevention of rejection of allogeneic endothelial cells in a biohybrid lung by silencing HLA-class I expression. Biomaterials, 35(28), 8123–8133. https://doi.org/10.1016/j.biomaterials.2014.06.007

1–25 of 46

Citations

  1. Pflaum, M., Barbian, K. P., Neuhaus, F., Sitarz, G., Nölke, C., Jansen, S. V., Linkhorst, J., Hirschwald, L. T., Brosch, S., Certa, C., Steinseifer, U., Wessling, M., Arens, J., Ruhparwar, A., & Wiegmann, B. (2026). From Fiber Bundles to Architected Membranes: Triply Periodic Minimal Surface Architectures for Biohybrid Artificial Lungs. Advanced Materials, 38(55), Article e74361. https://doi.org/10.1002/adma.74361
  2. He, W., Karmakar, A., & Antaki, J. F. (2026). Computational Fluid Dynamics Simulation of Endothelium-Modulated Thrombosis. Journal of Cardiovascular Translational Research, 19(1). https://doi.org/10.1007/s12265-026-10749-9
  3. Cheremkhina, M., Babendreyer, A., Neullens, C. T., Krapp, S., Pabst, A., Ohl, K., Ruetten, S., Ludwig, A., Cornelissen, C. G., Jockenhoevel, S., Tenbrock, K., & Thiebes, A. L. (2026). Modelling inflammatory endothelial dysfunction: a human in vitro platform for translational research. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1792998
  4. Barbian, K. P., Lemainque, T., Grunden, I., Iwa, R., Wiegmann, B., Linkhorst, J., Wessling, M., Heyer, J., Steinseifer, U., Neidlin, M., & Jansen, S. V. (2025). Tailored 3D Lattice Microstructures for Enhanced Functionality in Blood‐Gas Exchange. Advanced Science, 12(25), Article 2501162. https://doi.org/10.1002/advs.202501162
  5. Szentgyorgyi, L., Butt, S. P., & Krishnamoorthy, B. (2025). Evolution of extracorporeal membrane oxygenation: historical milestones and advanced developments. The Journal of ExtraCorporeal Technology, 57(4), 243–262. https://doi.org/10.1051/ject/2025033
  6. Haritz, J. L., Pflaum, M., Güntner, H. J., Katsirntaki, K., Hegermann, J., Hehnen, F., Lommel, M., Kertzscher, U., Arens, J., Haverich, A., Ruhparwar, A., & Wiegmann, B. (2024). Citrate‐Coated Iron Oxide Nanoparticles Facilitate Endothelialization of Left Ventricular Assist Device Impeller for Improved Antithrombogenicity. Advanced Science, 12(6), Article 2408976. https://doi.org/10.1002/advs.202408976
  7. Nwanna-Nzewunwa, O., & Keshavamurthy, S. (2024). ECMO – Current Applications, Technological Advances and Future Directions. In Evolving Therapies and Technologies in Extracorporeal Membrane Oxygenation. IntechOpen. https://doi.org/10.5772/intechopen.1005329
  8. Cheremkhina, M., Babendreyer, A., Neullens, C. T., Krapp, S., Pabst, A., Ohl, K., Ruetten, S., Ludwig, A., Cornelissen, C. G., Jockenhoevel, S., Tenbrock, K., & Thiebes, A. L. (2023). Modelling Inflammatory Endothelial Dysfunction: A Human In Vitro Platform for Translational Research. In bioRxiv. openRxiv. https://doi.org/10.1101/2023.10.31.564901
  9. Barbian, K. P., Hirschwald, L. T., Linkhorst, J., Neidlin, M., Steinseifer, U., Wessling, M., Wiegmann, B., & Jansen, S. V. (2023). Flow and Mass Transfer Prediction in Anisotropic Tpms-Structures as Extracorporeal Oxygenator Membranes Using Reduced Order Modeling. Elsevier BV. https://doi.org/10.2139/ssrn.4514006
  10. Davidy, A. (2023). Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane. ChemEngineering, 7(4), 60. https://doi.org/10.3390/chemengineering7040060
  11. Cheremkhina, M., Klein, S., Babendreyer, A., Ludwig, A., Schmitz-Rode, T., Jockenhoevel, S., Cornelissen, C. G., & Thiebes, A. L. (2023). Influence of Aerosolization on Endothelial Cells for Efficient Cell Deposition in Biohybrid and Regenerative Applications. Micromachines, 14(3), 575. https://doi.org/10.3390/mi14030575
  12. Strudthoff, L. J., Focke, J., Hesselmann, F., Kaesler, A., Martins Costa, A., Schlanstein, P. C., Schmitz-Rode, T., Steinseifer, U., Steuer, N. B., Wiegmann, B., Arens, J., & Jansen, S. V. (2023). Novel Size-Variable Dedicated Rodent Oxygenator for ECLS Animal Models—Introduction of the "RatOx" Oxygenator and Preliminary In Vitro Results. Micromachines, 14(4), 800. https://doi.org/10.3390/mi14040800