Feasibility and First Results of Heart Failure Monitoring Using the Wearable Cardioverter–Defibrillator in Newly Diagnosed Heart Failure with Reduced Ejection Fraction
Authors/Creators
-
1.
Medizinische Hochschule Hannover
- 2. Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, 30625 Hannover, Germany
Description
The wearable cardioverter–defibrillator (WCD) is used in patients with newly diagnosed heart failure and reduced ejection fraction (HFrEF). In addition to arrhythmic events, the WCD provides near-continuous telemetric heart failure monitoring. The purpose of this study was to evaluate the clinical relevance of additionally recorded parameters, such as heart rate or step count. We included patients with newly diagnosed HFrEF prescribed with a WCD. Via the WCD, step count and heart rate were acquired, and an approximate for heart rate variability (HRV5) was calculated. Multivariate analysis was performed to analyze predictors for an improvement in left ventricular ejection fraction (LVEF). Two hundred and seventy-six patients (31.9% female) were included. Mean LVEF was 25.3 ± 8.5%. Between the first and last seven days of usage, median heart rate fell significantly (p < 0.001), while median step count and HRV5 significantly increased (p < 0.001). In a multivariate analysis, a delta of HRV5 > 23 ms was an independent predictor for LVEF improvement of ≥10% between prescription and 3-month follow-up. Patients with newly diagnosed HFrEF showed significant changes in heart rate, step count, and HRV5 between the beginning and end of WCD prescription time. HRV5 was an independent predictor for LVEF improvement and could serve as an early indicator of treatment response.
Additional details
Identifiers
- OpenAlex
- W3217176079
- PMID
- 34883802
- URL
- https://www.mdpi.com/1424-8220/21/23/7798
Dates
- Issued
-
November 23, 2021
References
- Duncker, D., Haghikia, A., König, T., Hohmann, S., Gutleben, K.-J., Westenfeld, R., Oswald, H., Klein, H., Bauersachs, J., Hilfiker-Kleiner, D., & Veltmann, C. (2014). Risk for Ventricular Fibrillation in Peripartum Cardiomyopathy with Severely Reduced Left Ventricular Function—Value of the Wearable Cardioverter/Defibrillator. European Journal of Heart Failure, 16(12), 1331–1336. https://doi.org/10.1002/ejhf.188
- Duncker, D., König, T., Hohmann, S., Bauersachs, J., & Veltmann, C. (2017). Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: Insights from the PROLONG study. Clinical Cardiology, 40(8), 586–590. https://doi.org/10.1002/clc.22706
- Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Wranicz, J., Malik, R., Morin, D. P., Zweibel, S., Buxton, A. E., Elayi, C. S., Chung, E. H., Rashba, E., Borggrefe, M., Hue, T. F., Maguire, C., Lin, F., Simon, J. A., Hulley, S., & Lee, B. K. (2018). Wearable Cardioverter–Defibrillator after Myocardial Infarction. New England Journal of Medicine, 379(13), 1205–1215. https://doi.org/10.1056/nejmoa1800781
- Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., Kirchhof, P., Kjeldsen, K., Kuck, K.-H., Hernandez-Madrid, A., Nikolaou, N., Norekvål, T. M., Spaulding, C., Van Veldhuisen, D. J., Group, E. S. D., … Parkhomenko, A. (2015). 2015 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. European Heart Journal, 36(41), 2793–2867. https://doi.org/10.1093/eurheartj/ehv316
- Deneke, T., Bosch, R., Eckardt, L., Nowak, B., Schwab, J. O., Sommer, P., Veltmann, C., & Helms, T. M. (2019). Der tragbare Kardioverter/Defibrillator (WCD) – Indikationen und Einsatz: Empfehlung der AG1 der Deutschen Gesellschaft für Kardiologie – Herz- und Kreislaufforschung e. V. (DGK). Der Kardiologe, 13(5), 292–304. https://doi.org/10.1007/s12181-019-0331-4
- 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death
- Duncker, D., Westenfeld, R., Konrad, T., Pfeffer, T., Correia de Freitas, C. A., Pfister, R., Thomas, D., Fürnkranz, A., Andrié, R. P., Napp, A., Schmitt, J., Karolyi, L., Wakili, R., Hilfiker-Kleiner, D., Bauersachs, J., & Veltmann, C. (2017). Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis. Clinical Research in Cardiology, 106(8), 582–589. https://doi.org/10.1007/s00392-017-1090-5
- Epstein, A. E., Abraham, W. T., Bianco, N. R., Kern, K. B., Mirro, M., Rao, S. V., Rhee, E. K., Solomon, S. D., & Szymkiewicz, S. J. (2013). Wearable Cardioverter-Defibrillator Use in Patients Perceived to Be at High Risk Early Post-Myocardial Infarction. Journal of the American College of Cardiology, 62(21), 2000–2007. https://doi.org/10.1016/j.jacc.2013.05.086
- Zishiri, E. T., Williams, S., Cronin, E. M., Blackstone, E. H., Ellis, S. G., Roselli, E. E., Smedira, N. G., Gillinov, A. M., Glad, J. A., Tchou, P. J., Szymkiewicz, S. J., & Chung, M. K. (2013). Early Risk of Mortality After Coronary Artery Revascularization in Patients With Left Ventricular Dysfunction and Potential Role of the Wearable Cardioverter Defibrillator. Circulation: Arrhythmia and Electrophysiology, 6(1), 117–128. https://doi.org/10.1161/circep.112.973552
- Rao, M., Goldenberg, I., Moss, A. J., Klein, H., Huang, D. T., Bianco, N. R., Szymkiewicz, S. J., Zareba, W., Brenyo, A., Buber, J., & Barsheshet, A. (2011). Wearable Defibrillator in Congenital Structural Heart Disease and Inherited Arrhythmias. The American Journal of Cardiology, 108(11), 1632–1638. https://doi.org/10.1016/j.amjcard.2011.07.021
- Opreanu, M., Wan, C., Singh, V., Salehi, N., Ahmad, J., Szymkiewicz, S. J., & Thakur, R. K. (2015). Wearable cardioverter-defibrillator as a bridge to cardiac transplantation: A national database analysis. The Journal of Heart and Lung Transplantation, 34(10), 1305–1309. https://doi.org/10.1016/j.healun.2015.04.004
- Salehi, N., Nasiri, M., Bianco, N. R., Opreanu, M., Singh, V., Satija, V., Jhand, A. S., Karapetyan, L., Safadi, A. R., Surapaneni, P., & Thakur, R. K. (2016). The Wearable Cardioverter Defibrillator in Nonischemic Cardiomyopathy: A US National Database Analysis. Canadian Journal of Cardiology, 32(10), 1247.e1–1247.e6. https://doi.org/10.1016/j.cjca.2015.12.035
- Wäßnig, N. K., Günther, M., Quick, S., Pfluecke, C., Rottstädt, F., Szymkiewicz, S. J., Ringquist, S., Strasser, R. H., & Speiser, U. (2016). Experience With the Wearable Cardioverter-Defibrillator in Patients at High Risk for Sudden Cardiac Death. Circulation, 134(9), 635–643. https://doi.org/10.1161/circulationaha.115.019124
- Erath, J. W., Vamos, M., Benz, A. P., & Hohnloser, S. H. (2017). Usefulness of the WCD in patients with suspected tachymyopathy. Clinical Research in Cardiology, 107(1), 70–75. https://doi.org/10.1007/s00392-017-1159-1
- The Wearable Cardioverter/Defibrillator—Toy or Tool?
- Duncker, D., & Veltmann, C. (2018). Role of the Wearable Defibrillator in Newly Diagnosed Heart Failure. Current Heart Failure Reports, 15(6), 368–375. https://doi.org/10.1007/s11897-018-0415-7
- Duncker, D., König, T., Hohmann, S., Bauersachs, J., & Veltmann, C. (2017). Avoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator—The PROLONG Study. Journal of the American Heart Association, 6(1). https://doi.org/10.1161/jaha.116.004512
- Mueller-Leisse, J., Brunn, J., Zormpas, C., Hohmann, S., Hillmann, H. A. K., Eiringhaus, J., Bauersachs, J., Veltmann, C., & Duncker, D. (2021). Extended Follow-Up After Wearable Cardioverter-Defibrillator Period: The PROLONG-II Study. ESC Heart Failure, 8(6), 5142–5148. https://doi.org/10.1002/ehf2.13586
- McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., Cleland, J. G. F., Coats, A. J. S., Crespo-Leiro, M. G., Farmakis, D., Gilard, M., Heymans, S., Hoes, A. W., Jaarsma, T., Jankowska, E. A., … Skibelund, A. K. (2021). 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. European Heart Journal, 42(36), 3599–3726. https://doi.org/10.1093/eurheartj/ehab368
- Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., Lancellotti, P., Muraru, D., Picard, M. H., Rietzschel, E. R., Rudski, L., Spencer, K. T., Tsang, W., & Voigt, J.-U. (2015). Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Journal of the American Society of Echocardiography, 28(1), 1–39.e14. https://doi.org/10.1016/j.echo.2014.10.003
- Task Force of the European Society of Cardiology and the North American Society of Pacing Electrophysiology (1996). Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Eur. Heart J., 17, 354–381.
- Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011). pROC: an open-source package for R and S+ to analyze and compare ROC curves. BMC Bioinformatics, 12(1). https://doi.org/10.1186/1471-2105-12-77
- Chung, M. K., Szymkiewicz, S. J., Shao, M., Zishiri, E., Niebauer, M. J., Lindsay, B. D., & Tchou, P. J. (2010). Aggregate National Experience With the Wearable Cardioverter-Defibrillator. Journal of the American College of Cardiology, 56(3), 194–203. https://doi.org/10.1016/j.jacc.2010.04.016
- Kutyifa, V., Moss, A. J., Klein, H., Biton, Y., McNitt, S., MacKecknie, B., Zareba, W., & Goldenberg, I. (2015). Use of the Wearable Cardioverter Defibrillator in High-Risk Cardiac Patients. Circulation, 132(17), 1613–1619. https://doi.org/10.1161/circulationaha.115.015677
- Veltmann, C., Winter, S., Duncker, D., Jungbauer, C. G., Wäßnig, N. K., Geller, J. C., Erath, J. W., Goeing, O., Perings, C., Ulbrich, M., Roser, M., Husser, D., Gansera, L. S., Soezener, K., Malur, F. M., Block, M., Fetsch, T., Kutyifa, V., & Klein, H. U. (2020). Protected risk stratification with the wearable cardioverter-defibrillator: results from the WEARIT-II-EUROPE registry. Clinical Research in Cardiology, 110(1), 102–113. https://doi.org/10.1007/s00392-020-01657-2
1–25 of 50
Citations
- Providência, R., Salih, A., Aidelsburger, P., Elayi, C. S., Narayanan, K., Piot, O., Casolo, G., Metra, M., Boveda, S., Marijon, E., & Duncker, D. (2026). Wearable cardioverter-defibrillator in patients with non-ischaemic cardiomyopathy: a meta-analysis. Heart, heartjnl-2025-326956. https://doi.org/10.1136/heartjnl-2025-326956
- Duncker, D., Hillmann, H. A. K., & Müller-Leisse, J. (2025). Telemonitoring bei Patienten mit kardialen implantierbaren elektronischen Devices und Herzinsuffizienz. Herzschrittmachertherapie + Elektrophysiologie, 36(1), 28–33. https://doi.org/10.1007/s00399-024-01062-6
- Guglieri, M., Lenormand, T., Bodin, A., Bisson, A., & Fauchier, L. (2025). Variabiliy in Prescribing Patterns of Wearable Cardiac Defibrillators: Current Data, Guidelines, Challenges, and Controversies. Current Cardiology Reports, 27(1). https://doi.org/10.1007/s11886-025-02321-9
- Hillmann, H. A. K., Hermans, A. N. L., Gawalko, M., Mueller-Leisse, J., Betz, K., Sohaib, A., Fung, C. H., Pisters, R., Lodziński, P., Chaldoupi, S.-M., Gupta, D., van der Velden, R. M. J., Pluymaekers, N. A. H. A., Sandgren, E., Nørregaard, M., Evens, S., De Cooman, T., Verhaert, D., Hemels, M., … Duncker, D. (2025). Ultra-short-term heart rate variability using a photoplethysmography-based smartphone application: a TeleCheck-AF subanalysis. European Heart Journal - Digital Health, 6(4), 675–682. https://doi.org/10.1093/ehjdh/ztaf035
- Lenormand, T., Bodin, A., & Fauchier, L. (2024). The Role of the Wearable Defibrillator in Heart Failure. Current Heart Failure Reports, 21(1), 33–42. https://doi.org/10.1007/s11897-023-00641-x
- Scholte, N. T. B., van Ravensberg, A. E., Shakoor, A., Boersma, E., Ronner, E., de Boer, R. A., Brugts, J. J., Bruining, N., & van der Boon, R. M. A. (2024). A scoping review on advancements in noninvasive wearable technology for heart failure management. Npj Digital Medicine, 7(1). https://doi.org/10.1038/s41746-024-01268-5
- Sridhar, A. R., Cheung, J. W., Lampert, R., Silva, J. N. A., Gopinathannair, R., Sotomonte, J. C., Tarakji, K., Fellman, M., Chrispin, J., Varma, N., Kabra, R., Mehta, N., Al-Khatib, S. M., Mayfield, J. J., Navara, R., Rajagopalan, B., Passman, R., Fleureau, Y., Shah, M. J., … Lakkireddy, D. (2024). State of the art of mobile health technologies use in clinical arrhythmia care. Communications Medicine, 4(1). https://doi.org/10.1038/s43856-024-00618-4
- Casolo, G., Gulizia, M. M., Aschieri, D., Chinaglia, A., Corda, M., Nassiacos, D., Caico, S. I., Chimenti, C., Giaccardi, M., Gotti, E., Maffé, S., Magnano, R., Solarino, G., Gabrielli, D., Oliva, F., & Colivicchi, F. (2023). ANMCO position paper: guide to the appropriate use of the wearable cardioverter defibrillator in clinical practice for patients at high transient risk of sudden cardiac death. European Heart Journal Supplements, 25(Supplement_D), D294–D311. https://doi.org/10.1093/eurheartjsupp/suad101
- Garcia, R., Warming, P. E., Narayanan, K., Defaye, P., Guedon-Moreau, L., Blangy, H., Piot, O., Leclercq, C., Marijon, E., Investigators, . the W.-F., Moreau, L. G., Mahfoud, M., Ritter, P., Dupuis, J. M., Yalioua, A., Dompnier, A., Goralski, M., Cheggour, S., Leclercq, C., … Chavernac, P. (2023). Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study. Europace, 25(5). https://doi.org/10.1093/europace/euad062
- Iliodromitis, K., Balogh, Z., Triposkiadis, F., Deftereos, S., Vrachatis, D., Bimpong-Buta, N.-Y., Schiedat, F., & Bogossian, H. (2023). Assessing physical activity with the wearable cardioverter defibrillator in patients with newly diagnosed heart failure. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1176710
- Olic, J.-J., Stöllberger, C., Schukro, C., Odening, K. E., Reuschel, E., Fischer, M., Veltmann, C., Duncker, D., & Baessler, A. (2022). Usage of the wearable cardioverter-defibrillator during pregnancy. IJC Heart & Vasculature, 41, Article 101066. https://doi.org/10.1016/j.ijcha.2022.101066
- Rohrer, U., Manninger, M., Zirlik, A., & Scherr, D. (2021). Multiparameter Monitoring with a Wearable Cardioverter Defibrillator. Sensors, 22(1), 22. https://doi.org/10.3390/s22010022