Published June 1997 | Journal article | Version v1 | https://doi.org/10.1007/s001670050032

Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: interference screw versus staple fixation in human knees

Description

AbstractThe endoscopic single incision technique for anterior cruciate ligament (ACL) reconstruction with a femoral half‐tunnel may lead to a graft/tunnel mismatch and subsequent protrusion of the block from the tibial tunnel. The typical tibial fixation with an interference screw is not possible in these cases. Fixation with staples in a bony groove inferior to the tunnel outlet can be used as an alternative technique. Current literature does not provide biomechanical data of either fixation technique in a human model. This study was performed to evaluate the primary biomechanical parameters of this technique compared with a standard interference screw fixation of the block. Fifty‐five fresh‐frozen relatively young (mean age 44 years) human cadaver knee joints were used. Grafts were harvested from the patellar tendon midportion with bone blocks of 25 mm length and 9 mm width. A 10‐mm tibial tunnel was drilled from the anteromedial cortex to the center of the tibial insertion of the ACL. Three different sizes of interference screws (7 × 30, 9 × 20, 9 × 30 mm) were chosen as a standard control procedure (n = 40). For tibial bone‐block fixation the graft was placed through the tunnel, and the screw was then inserted on the cancellous or the cortical surface, respectively. Fifteen knees were treated by staple fixation. A groove was created inferior to the tunnel outlet with a chisel. The bone block was fixed in this groove with two barbed stainless steel staples. Tensile testing in both groups was carried out under an axial load parallel to the tibial tunnel in a Zwick testing machine with a velocity of 1 mm/s. Dislocation of the graft and stiffness were calculated at 175 N load. Maximum load to failure using interference screws varied between 506 and 758 N. Load to failure using staples was 588 N. Dislocation of the graft ranged between 3.8 and 4.7 mm for interference screw fixation and was 4.7 mm for staples. Stiffness calculated at 175 N load was significantly higher in staple fixation. With either fixation technique, the recorded failure loads were sufficient to withstand the graft loads which are to be expected during the rehabilitation period. Staple fixation of the bone block outside of the tunnel resulted in a fixation strength comparable to interference screw fixation.

Additional details

Dates

Issued
June 1997

Citations

  1. https://doi.org/10.1177/03635465261428673
  2. Wang, K. C., Keeley, T., & Lansdown, D. A. (2025). Anterior Cruciate Ligament Reconstruction: Common Intraoperative Mistakes and Techniques for Error Recovery. Current Reviews in Musculoskeletal Medicine, 18(12), 645–657. https://doi.org/10.1007/s12178-025-09947-w
  3. Sidharthan, S., & Bhattacharya, R. (2024). Technology Update in Management of Multi-Ligament Knee Injuries. Indian Journal of Orthopaedics, 58(11), 1537–1547. https://doi.org/10.1007/s43465-024-01281-6
  4. Yıldırım, C., Demirel, M., Koraman, E., Muratoğlu, O. G., Yamak, F., Bozdağ, S. E., & Kocabey, Y. (2024). The Effect of Supplementary Staple Fixation on Biomechanical Properties of Soft Tissue Graft Tibial Fixation in Anterior Cruciate Ligament Reconstruction. The Journal of Knee Surgery, 37(10), 736–741. https://doi.org/10.1055/s-0044-1786007
  5. Praz, C., Cottebrune, T., Ferreira, A., & Hulet, C. (2023). Reconstruction du ligament croisé antérieur par autogreffe de ligament patellaire. In L'arthroscopie du Genou (pp. 195–205.e2). Elsevier. https://doi.org/10.1016/b978-2-294-76665-7.00025-6
  6. Dwyer, T., Hoit, G., Sellan, M., Gopinath, R., Whelan, D., Theodoropoulos, J., & Chahal, J. (2022). Six Percent Incidence of Graft-Tunnel Mismatch in Anatomic Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft and Anteromedial Portal Drilling. Arthroscopy, Sports Medicine, and Rehabilitation, 4(2), e479–e486. https://doi.org/10.1016/j.asmr.2021.11.006
  7. https://doi.org/10.1097/jsa.0000000000000315
  8. https://doi.org/10.18621/eurj.904343
  9. Sheean, A. J., Nickoli, M. S., Villa Albers, M. B., & Fu, F. H. (2019). Intraoperative. In Complications in Orthopaedics: Sports Medicine (pp. 51–58). Elsevier. https://doi.org/10.1016/b978-0-323-54598-3.00007-2
  10. Ganokroj, P., Polklaew, T., & Lertwanich, P. (2019). Determination of patellar tendon length for anterior cruciate ligament reconstruction using an anteroposterior knee radiograph. Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 16, 1–7. https://doi.org/10.1016/j.asmart.2018.12.001
  11. Oikawa, R., Tajima, G., Yan, J., Maruyama, M., Sugawara, A., Oikawa, S., Saigo, T., Takahashi, H., & Doita, M. (2019). Morphology of the patellar tendon and its insertion sites using three-dimensional computed tomography: A cadaveric study. The Knee, 26(2), 302–309. https://doi.org/10.1016/j.knee.2018.12.002
  12. Bauer, L. A. de R., Alberti, H. A. A., Corotti, V. G. de P., Franco, A. P. G. de O., Stieven Filho, E., & Cunha, L. A. M. da . (2018). Análise biomecânica da dupla fixação de enxerto tendinoso em tíbia porcina – uso de parafuso de interferência e agrafe. Revista Brasileira de Ortopedia, 53(5), 564–569. https://doi.org/10.1016/j.rbo.2017.05.014
  13. Bauer, L. A. de R., Alberti, H. A. A., Corotti, V. G. de P., Franco, A. P. G. de O., Stieven Filho, E., & Cunha, L. A. M. da . (2018). Biomechanical analysis of a double fixation method for tendon graft in porcine tibia – using an interference screw plus staple. Revista Brasileira De Ortopedia (English Edition), 53(5), 564–569. https://doi.org/10.1016/j.rboe.2018.07.003
  14. Noyes, F. R., & Barber-Westin, S. D. (2017). Posterior Cruciate Ligament Injuries. In Noyes' Knee Disorders: Surgery, Rehabilitation, Clinical Outcomes (pp. 447–526). Elsevier. https://doi.org/10.1016/b978-0-323-32903-3.00016-0
  15. https://doi.org/10.1177/2309499017690983
  16. Arnold, M. P., Burger, L. D., Wirz, D., Goepfert, B., & Hirschmann, M. T. (2016). The biomechanical strength of a hardware-free femoral press-fit method for ACL bone–tendon–bone graft fixation. Knee Surgery, Sports Traumatology, Arthroscopy, 25(4), 1234–1240. https://doi.org/10.1007/s00167-015-3960-6
  17. Milano, G., Petersen, W., Hoeher, J., Paessler, H. H., Akoto, R., Campana, V., Saccomanno, M. F., & Siebold, R. (2014). Fixation. In Anterior Cruciate Ligament Reconstruction (pp. 215–256). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-45349-6_24
  18. Mall, N. A., Heard, W. M. R., Verma, N. N., & Bach, B. R. (2013). Fixation in Revision ACL Reconstruction. In Revision ACL Reconstruction (pp. 105–117). Springer New York. https://doi.org/10.1007/978-1-4614-0766-9_11
  19. Hsu, S.-L., & Wang, C.-J. (2013). Graft failure versus graft fixation in ACL reconstruction: histological and immunohistochemical studies in rabbits. Archives of Orthopaedic and Trauma Surgery, 133(9), 1197–1202. https://doi.org/10.1007/s00402-013-1790-x
  20. https://doi.org/10.1097/bto.0b013e3182596417
  21. Saccomanni, B. (2011). RETRACTED ARTICLE: Graft fixation alternatives in anterior cruciate ligament reconstruction. MUSCULOSKELETAL SURGERY, 95(3), 183–191. https://doi.org/10.1007/s12306-011-0137-4
  22. Rodríguez, C., Maestro, A., García, T. E., & Rodríguez, L. (2011). Comportamiento biomecánico bajo carga estática de diferentes sistemas de fijación femoral para la reconstrucción del ligamento cruzado anterior. Revista Española de Cirugía Ortopédica y Traumatología, 55(6), 428–436. https://doi.org/10.1016/j.recot.2011.07.002
  23. Rodríguez, C., Maestro, A., García, T. E., & Montes, S. (2011). Static load biomechanical behaviour of different femoral fixation systems for anterior cruciate ligament reconstruction. Revista Española De Cirugía Ortopédica Y Traumatología (English Edition), 55(6), 428–436. https://doi.org/10.1016/j.recote.2011.07.001
  24. https://doi.org/10.2106/jbjs.j.00269
  25. Clark, N., & Herrington, D. L. (2010, May 14). The knee. In Sports Rehabilitation and Injury Prevention (1st ed., pp. 407–463). Wiley. https://doi.org/10.1002/9781118685150.ch21

1–25 of 54