Published July 28, 2016 | Journal article | Version v1 | https://doi.org/10.1093/eurheartj/ehw231

Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis

Additional details

Dates

Issued
July 28, 2016

References

  1. Li, J. S., Sexton, D. J., Mick, N., Nettles, R., Fowler, V. G., Ryan, T., Bashore, T., & Corey, G. R. (2000). Proposed Modifications to the Duke Criteria for the Diagnosis of Infective Endocarditis. Clinical Infectious Diseases, 30(4), 633–638. https://doi.org/10.1086/313753
  2. Habib, G., Derumeaux, G., Avierinos, J.-F., Casalta, J.-P., Jamal, F., Volot, F., Garcia, M., Lefevre, J., Biou, F., Maximovitch-Rodaminoff, A., Fournier, P. E., Ambrosi, P., Velut, J.-G., Cribier, A., Harle, J.-R., Weiller, P.-J., Raoult, D., & Luccioni, R. (1999). Value and limitations of the duke criteria for the diagnosis of infective endocarditis. Journal of the American College of Cardiology, 33(7), 2023–2029. https://doi.org/10.1016/s0735-1097(99)00116-3
  3. Habib, G., Lancellotti, P., Antunes, M. J., Bongiorni, M. G., Casalta, J.-P., Del Zotti, F., Dulgheru, R., El Khoury, G., Erba, P. A., Iung, B., Miro, J. M., Mulder, B. J., Plonska-Gosciniak, E., Price, S., Roos-Hesselink, J., Snygg-Martin, U., Thuny, F., Tornos Mas, P., Vilacosta, I., … Nesukay, E. (2015). 2015 ESC Guidelines for the management of infective endocarditis. European Heart Journal, 36(44), 3075–3128. https://doi.org/10.1093/eurheartj/ehv319
  4. Rouzet, F., Chequer, R., Benali, K., Lepage, L., Ghodbane, W., Duval, X., Iung, B., Vahanian, A., Le Guludec, D., & Hyafil, F. (2014). Respective Performance of 18 F-FDG PET and Radiolabeled Leukocyte Scintigraphy for the Diagnosis of Prosthetic Valve Endocarditis. Journal of Nuclear Medicine, 55(12), 1980–1985. https://doi.org/10.2967/jnumed.114.141895
  5. Indium-111 leukocyte scintigraphic detection of myocardial abscess formation in patients with endocarditis
  6. Erba, P. A., Sollini, M., Conti, U., Bandera, F., Tascini, C., De Tommasi, S. M., Zucchelli, G., Doria, R., Menichetti, F., Bongiorni, M. G., Lazzeri, E., & Mariani, G. (2013). Radiolabeled WBC Scintigraphy in the Diagnostic Workup of Patients With Suspected Device-Related Infections. JACC: Cardiovascular Imaging, 6(10), 1075–1086. https://doi.org/10.1016/j.jcmg.2013.08.001
  7. Buechel, R. R., Herzog, B. A., Husmann, L., Burger, I. A., Pazhenkottil, A. P., Treyer, V., Valenta, I., von Schulthess, P., Nkoulou, R., Wyss, C. A., & Kaufmann, P. A. (2010). Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. European Journal of Nuclear Medicine and Molecular Imaging, 37(4), 773–778. https://doi.org/10.1007/s00259-009-1375-7
  8. Imbert, L., Poussier, S., Franken, P. R., Songy, B., Verger, A., Morel, O., Wolf, D., Noel, A., Karcher, G., & Marie, P.-Y. (2012). Compared Performance of High-Sensitivity Cameras Dedicated to Myocardial Perfusion SPECT: A Comprehensive Analysis of Phantom and Human Images. Journal of Nuclear Medicine, 53(12), 1897–1903. https://doi.org/10.2967/jnumed.112.107417
  9. Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010). A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. European Journal of Nuclear Medicine and Molecular Imaging, 37(10), 1887–1902. https://doi.org/10.1007/s00259-010-1488-z
  10. Nichols, K. J. (2007). Regarding the virtues and limitations of combining myocardial perfusion SPECT data acquired by diverse methods. Journal of Nuclear Cardiology, 14(1), 4–5. https://doi.org/10.1016/j.nuclcard.2006.11.008
  11. In vivo visualization of 111In labeled CD133+ peripheral blood stem cells after intracoronary administration in patients with chronic ischemic heart disease
  12. Roca, M., de Vries, E. F. J., Jamar, F., Israel, O., & Signore, A. (2010). Guidelines for the labelling of leucocytes with 111In-oxine. European Journal of Nuclear Medicine and Molecular Imaging, 37(4), 835–841. https://doi.org/10.1007/s00259-010-1393-5
  13. Loening, A. M., & Gambhir, S. S. (2003). AMIDE: A Free Software Tool for Multimodality Medical Image Analysis. Molecular Imaging, 2(3), 131–137. https://doi.org/10.1162/153535003322556877
  14. Cervo, M., Gerbaudo, V. H., Park, M.-A., & Moore, S. C. (2013). Quantitative simultaneous 111 In/99m Tc SPECT-CT of osteomyelitis. Medical Physics, 40(8), 082501. https://doi.org/10.1118/1.4812421
  15. Ben-Haim, S., Kacperski, K., Hain, S., Van Gramberg, D., Hutton, B. F., Erlandsson, K., Sharir, T., Roth, N., Waddington, W. A., Berman, D. S., & Ell, P. J. (2010). Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. European Journal of Nuclear Medicine and Molecular Imaging, 37(9), 1710–1721. https://doi.org/10.1007/s00259-010-1441-1
  16. Kraitchman, D. L., Tatsumi, M., Gilson, W. D., Ishimori, T., Kedziorek, D., Walczak, P., Segars, W. P., H. Chen, H., Fritzges, D., Izbudak, I., Young, R. G., Marcelino, M., Pittenger, M. F., Solaiyappan, M., Boston, R. C., Tsui, B. M. W., Wahl, R. L., & Bulte, J. W. M. (2005). Dynamic Imaging of Allogeneic Mesenchymal Stem Cells Trafficking to Myocardial Infarction. Circulation, 112(10), 1451–1461. https://doi.org/10.1161/circulationaha.105.537480
  17. Schächinger, V., Aicher, A., Döbert, N., Röver, R., Diener, J., Fichtlscherer, S., Assmus, B., Seeger, F. H., Menzel, C., Brenner, W., Dimmeler, S., & Zeiher, A. M. (2008). Pilot Trial on Determinants of Progenitor Cell Recruitment to the Infarcted Human Myocardium. Circulation, 118(14), 1425–1432. https://doi.org/10.1161/circulationaha.108.777102
  18. Matsunari, I., Schricke, U., Bengel, F. M., Haase, H.-U., Barthel, P., Schmidt, G., Nekolla, S. G., Schoemig, A., & Schwaiger, M. (2000). Extent of Cardiac Sympathetic Neuronal Damage Is Determined by the Area of Ischemia in Patients With Acute Coronary Syndromes. Circulation, 101(22), 2579–2585. https://doi.org/10.1161/01.cir.101.22.2579
  19. Thackeray, J. T., & Bengel, F. M. (2016). Translational Molecular Nuclear Cardiology. Cardiology Clinics, 34(1), 187–198. https://doi.org/10.1016/j.ccl.2015.08.004
  20. Evangelista, A., & Gonzalez-Alujas, M. T. (2004). Echocardiography in infective endocarditis. Heart, 90(6), 614–617. https://doi.org/10.1136/hrt.2003.029868
  21. Thuny, F., Gaubert, J.-Y., Jacquier, A., Tessonnier, L., Cammilleri, S., Raoult, D., & Habib, G. (2013). Imaging investigations in infective endocarditis: Current approach and perspectives. Archives of Cardiovascular Diseases, 106(1), 52–62. https://doi.org/10.1016/j.acvd.2012.09.004
  22. Lancellotti, P., Habib, G., Oury, C., & Nchimi, A. (2015). Positron Emission Tomography/Computed Tomography Imaging in Device Infective Endocarditis. Circulation, 132(12), 1076–1080. https://doi.org/10.1161/circulationaha.115.018521
  23. Einstein, A. J., Blankstein, R., Andrews, H., Fish, M., Padgett, R., Hayes, S. W., Friedman, J. D., Qureshi, M., Rakotoarivelo, H., Slomka, P., Nakazato, R., Bokhari, S., Di Carli, M., & Berman, D. S. (2014). Comparison of Image Quality, Myocardial Perfusion, and Left Ventricular Function Between Standard Imaging and Single-Injection Ultra-Low-Dose Imaging Using a High-Efficiency SPECT Camera: The MILLISIEVERT Study. Journal of Nuclear Medicine, 55(9), 1430–1437. https://doi.org/10.2967/jnumed.114.138222
  24. Lautamäki, R., Brown, T. L. Y., Merrill, J., & Bengel, F. M. (2007). CT-based attenuation correction in 82Rb-myocardial perfusion PET–CT: incidence of misalignment and effect on regional tracer distribution. European Journal of Nuclear Medicine and Molecular Imaging, 35(2), 305–310. https://doi.org/10.1007/s00259-007-0607-y
  25. Goetze, S., Brown, T. L., Lavely, W. C., Zhang, Z., & Bengel, F. M. (2007). Attenuation Correction in Myocardial Perfusion SPECT/CT: Effects of Misregistration and Value of Reregistration. Journal of Nuclear Medicine, 48(7), 1090–1095. https://doi.org/10.2967/jnumed.107.040535

1–25 of 26

Citations

  1. Caobelli, F., Dweck, M. R., Albano, D., Gheysens, O., Georgoulias, P., Nekolla, S., Lairez, O., Leccisotti, L., Lubberink, M., Massalha, S., Nappi, C., Rischpler, C., Saraste, A., & Hyafil, F. (2024). Hybrid cardiovascular imaging. A clinical consensus statement of the european association of nuclear medicine (EANM) and the european association of cardiovascular imaging (EACVI) of the ESC. European Journal of Nuclear Medicine and Molecular Imaging, 52(3), 1095–1118. https://doi.org/10.1007/s00259-024-06946-w
  2. Mulgaonkar, A., Udayakumar, D., Yang, Y., Harris, S., Öz, O. K., Ramakrishnan Geethakumari, P., & Sun, X. (2023). Current and potential roles of immuno-PET/-SPECT in CAR T-cell therapy. Frontiers in Medicine, 10. https://doi.org/10.3389/fmed.2023.1199146
  3. Uenomachi, M., Takahashi, M., Shimazoe, K., Takahashi, H., Kamada, K., Orita, T., Ogane, K., & Tsuji, A. B. (2021). Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-97302-7
  4. Wu, J., & Liu, C. (2019). Recent advances in cardiac SPECT instrumentation and imaging methods. Physics in Medicine & Biology, 64(6), 06TR01. https://doi.org/10.1088/1361-6560/ab04de
  5. Thackeray, J. T. (2018). PET Assessment of Immune Cell Activity and Therapeutic Monitoring Following Myocardial Infarction. Current Cardiology Reports, 20(3), Article 13. https://doi.org/10.1007/s11886-018-0955-1
  6. Kircher, M., & Lapa, C. (2017). Novel Noninvasive Nuclear Medicine Imaging Techniques for Cardiac Inflammation. Current Cardiovascular Imaging Reports, 10(2). https://doi.org/10.1007/s12410-017-9400-x
  7. Sollini, M., Boni, R., Antunovic, L., Kirienko, M., Lazzeri, E., & Erba, P. A. (2017). The Role of Nuclear Cardiac Imaging in Infective Endocarditis. Current Cardiovascular Imaging Reports, 10(7). https://doi.org/10.1007/s12410-017-9421-5
  8. Marchetta, S., Withofs, N., Erba, P. A., Habib, G., Hustinx, R., & Lancellotti, P. (2017). Radionuclide Imaging of Infective Endocarditis: State of Art and Future Perspective. Current Cardiovascular Imaging Reports, 10(8). https://doi.org/10.1007/s12410-017-9425-1
  9. Delgado, V., Gaemperli, O., Lombardi, M., Kaufmann, P. A., & Bax, J. J. (2017). The year in cardiology 2016: imaging. European Heart Journal, ehw633. https://doi.org/10.1093/eurheartj/ehw633
  10. Sohns, J. M., Bavendiek, U., Ross, T. L., & Bengel, F. M. (2017). Targeting Cardiovascular Implant Infection. Circulation: Cardiovascular Imaging, 10(12). https://doi.org/10.1161/circimaging.117.005376