Published November 22, 2005 | Journal article | Version v1 | https://doi.org/10.1007/s00167-005-0704-z

The influence of pre‐tensioning of meniscal transplants on the tibiofemoral contact area

Description

AbstractThe purpose of the present study was to determine the effect of biological in‐growth and pre‐tensioning on the load transmission function of meniscal transplants. The ability of meniscal transplants to transfer load to the tibial plateau was measured in an animal model. Thirty‐six sheep were divided into six groups: group A was the sham group, in group B a medial meniscectomy was performed, and in groups C–F a medial meniscal transplantation with an autograft was carried out. In groups C–F, different levels of pre‐tensioning force were applied via bone tunnel sutures (C=0, D=20, E=40, and F=60 N, respectively). The animals were killed after 6 months. The excised knees were mounted in a materials testing machine at 30, 60, and 90° of flexion, and loaded through the femoral axis to 500 N. A thin film pressure measuring transducer (K‐scan, Tekscan®) was positioned underneath the meniscus in the medial compartment in order to determine contact area and pressure. The mean contact pressure (MCP) of the sham group (A) and the groups with the transplanted meniscus (C–F) was significantly lower in relation to the meniscectomized knees (B). Significant increases in contact area and reductions in peak contact pressure were also observed. Only the meniscal transplantation group with 40 N (E) pre‐tension consistently showed a significant or strong trend toward increased contact area, compared to the meniscectomized knees (B) at all flexion angles tested. All meniscal transplanted groups with the exception of the 0 N group (C) showed a significant reduction in peak contact pressure in comparison to the meniscectomized group (B). The results indicate that meniscal transplantation reduces the MCP on the tibial plateau independent of the level of intraoperative pre‐tensioning. Furthermore, the menisci pre‐tensioned to 40 N showed significantly increased contact area and reduced peak contact pressure in comparison to the meniscectomized knees at all flexion angles tested, and revealed results similar to those reported in the literature for meniscal allografts fixated with bone plugs.

Additional details

Dates

Issued
November 22, 2005

References

  1. Ahmed, A. M., & Burke, D. L. (1983). In-Vitro of Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the Knee. Journal of Biomechanical Engineering, 105(3), 216–225. https://doi.org/10.1115/1.3138409
  2. Alhalki, M. M., Howell, S. M., & Hull, M. L. (1999). How Three Methods for Fixing a Medial Meniscal Autograft Affect Tibial Contact Mechanics. The American Journal of Sports Medicine, 27(3), 320–328. https://doi.org/10.1177/03635465990270030901
  3. Alhalki, M. M., Hull, M. L., & Howell, S. M. (2000). Contact Mechanics of the Medial Tibial Plateau after Implantation of a Medial Meniscal Allograft. The American Journal of Sports Medicine, 28(3), 370–376. https://doi.org/10.1177/03635465000280031501
  4. Allen, P., Denham, R., & Swan, A. (1984). Late degenerative changes after meniscectomy. Factors affecting the knee after operation. The Journal of Bone and Joint Surgery. British Volume, 66-B(5), 666–671. https://doi.org/10.1302/0301-620x.66b5.6548755
  5. Andrish, J. T., Kambic, H. E., Valdevit, A. D. C., Kuroda, R., Parker, R. D., Aronowitz, E., & Elster, T. (2001). Selected Knee Osteotomies and Meniscal Replacement: Effects on Dynamic Intra-Joint Loading. The Journal of Bone and Joint Surgery-American Volume, 83, 142–150. https://doi.org/10.2106/00004623-200100022-00012
  6. https://doi.org/10.1302/0301%E2%80%90620x.84b2.12443 https://doi.org/10.1302/0301%E2%80%90620x.84b2.12443
  7. Arnoczky, S. P., Warren, R. F., & Spivak, J. M. (1988). Meniscal repair using an exogenous fibrin clot. An experimental study in dogs. The Journal of Bone & Joint Surgery, 70(8), 1209–1217. https://doi.org/10.2106/00004623-198870080-00012
  8. https://doi.org/10.1016/0021%E2%80%909290(91)90340%E2%80%90s https://doi.org/10.1016/0021%E2%80%909290(91)90340%E2%80%90s
  9. Bach, J. M., & Hull, M. L. (1995). A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint. Journal of Biomechanical Engineering, 117(4), 373–382. https://doi.org/10.1115/1.2794195
  10. Baratz, M. E., Fu, F. H., & Mengato, R. (1986). Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. The American Journal of Sports Medicine, 14(4), 270–275. https://doi.org/10.1177/036354658601400405
  11. Baratz, M. E., Rehak, D. C., Fu, F. H., & Rudert, M. J. (1988). Peripheral tears of the meniscus. The American Journal of Sports Medicine, 16(1), 1–6. https://doi.org/10.1177/036354658801600101
  12. Pickles, D. M., & Bellenger, C. R. (1993). Load-Bearing in the Ovine Medial Tibial Condyle: Effect of Meniscectomy. Veterinary and Comparative Orthopaedics and Traumatology, 06(02), 100–104. https://doi.org/10.1055/s-0038-1633027
  13. Die Bewegungen des Kniegelenkes nach einer neuen Methode an lebenden Menschen gemessen
  14. Brown, T. D., & Shaw, D. T. (1984). In vitro contact stress distribution on the femoral condyles. Journal of Orthopaedic Research, 2(2), 190–199. https://doi.org/10.1002/jor.1100020210
  15. https://doi.org/10.1016/0021%E2%80%909290(94)90018%E2%80%903 https://doi.org/10.1016/0021%E2%80%909290(94)90018%E2%80%903
  16. Bylski‐Austrow, D. I., Malumed, J., Meade, T., & Grood, E. S. (1993). Knee joint contact pressure decreases after chronic meniscectomy relative to the acutely meniscectomized joint: A mechanical study in the goat. Journal of Orthopaedic Research, 11(6), 796–804. https://doi.org/10.1002/jor.1100110604
  17. Cameron, J. C., & Saha, S. (1997). Meniscal Allograft Transplantation for Unicompartmental Arthritis of the Knee. Clinical Orthopaedics and Related Research, 337, 164–171. https://doi.org/10.1097/00003086-199704000-00018
  18. Carter, T. R. (1999). Meniscal Allograft Transplantation. Sports Medicine and Arthroscopy Review, 7(1), 51–62. https://doi.org/10.1097/00132585-199901000-00008
  19. https://doi.org/10.1016/s0749%E2%80%908063(96)90007%E2%80%909 https://doi.org/10.1016/s0749%E2%80%908063(96)90007%E2%80%909
  20. Cook, J. L., Tomlinson, J. L., Arnoczky, S. P., Fox, D. B., Cook, C. R., & Kreeger, J. M. (2001). Kinetic Study of the Replacement of Porcine Small Intestinal Submucosa Grafts and the Regeneration of Meniscal-Like Tissue in Large Avascular Meniscal Defects in Dogs. Tissue Engineering, 7(3), 321–334. https://doi.org/10.1089/10763270152044189
  21. Fairbank, T. J. (1948). KNEE JOINT CHANGES AFTER MENISCECTOMY. The Journal of Bone and Joint Surgery. British Volume, 30-B(4), 664–670. https://doi.org/10.1302/0301-620x.30b4.664
  22. FITHIAN, D. C., KELLY, M. A., & MOW, V. C. (1990). Material Properties and Structure-Function Relationships in the Menisci. Clinical Orthopaedics and Related Research, 252, 19–31. https://doi.org/10.1097/00003086-199003000-00004
  23. Fukubayashi, T., & Kurosawa, H. (1980). The Contact Area and Pressure Distribution Pattern of the Knee: A Study of Normal and Osteoarthrotic Knee Joints. Acta Orthopaedica Scandinavica, 51(1-6), 871–879. https://doi.org/10.3109/17453678008990887
  24. Gao, J., Wei, X., & Messner, K. (1998). Healing of the Anterior Attachment of the Rabbit Meniscus to Bone. Clinical Orthopaedics and Related Research, 348, 246???258. https://doi.org/10.1097/00003086-199803000-00036
  25. Garrett, J. C. (1993). Meniscal Transplantation. Sports Medicine and Arthroscopy Review, 1(2), 164–167. https://doi.org/10.1097/00132585-199300120-00010

1–25 of 68

Citations

  1. Boksh, K., Bashabayev, B., Shepherd, D. E. T., Espino, D. M., Ghosh, A., Aujla, R., & Boutefnouchet, T. (2025). Pressure Sensors for Measuring Tibiofemoral Contact Mechanics in Meniscal Root Repair: A Systematic Review. Sensors, 25(5), 1507. https://doi.org/10.3390/s25051507
  2. Kumar, M., & Venkatachalam, S. (2022). Pressure Mapping System for Marine Structure Application: An alternate approach with validation. OCEANS 2022 - Chennai, 1–9. https://doi.org/10.1109/oceanschennai45887.2022.9775340
  3. Seitz, A. M., & Dürselen, L. (2018). Biomechanical considerations are crucial for the success of tendon and meniscus allograft integration—a systematic review. Knee Surgery, Sports Traumatology, Arthroscopy, 27(6), 1708–1716. https://doi.org/10.1007/s00167-018-5185-y
  4. Vrancken, A. C. T., Hannink, G., Madej, W., Verdonschot, N., van Tienen, T. G., & Buma, P. (2017). In Vivo Performance of a Novel, Anatomically Shaped, Total Meniscal Prosthesis Made of Polycarbonate Urethane: A 12-Month Evaluation in Goats. The American Journal of Sports Medicine, 45(12), 2824–2834. https://doi.org/10.1177/0363546517713687
  5. Vrancken, A. C. T., Eggermont, F., van Tienen, T. G., Hannink, G., Buma, P., Janssen, D., & Verdonschot, N. (2015). Functional biomechanical performance of a novel anatomically shaped polycarbonate urethane total meniscus replacement. Knee Surgery, Sports Traumatology, Arthroscopy, 24(5), 1485–1494. https://doi.org/10.1007/s00167-015-3632-6
  6. Jansson, K. S., Michalski, M. P., Smith, S. D., LaPrade, R. F., & Wijdicks, C. A. (2013). Tekscan pressure sensor output changes in the presence of liquid exposure. Journal of Biomechanics, 46(3), 612–614. https://doi.org/10.1016/j.jbiomech.2012.09.033
  7. Verdonk, R., Verdonk, P., & Almqvist, K. F. (2011). Meniscal Allografts: Indications and Results. In Sports Injuries (pp. 321–327). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-15630-4_43
  8. Ballyns, J. J., & Bonassar, L. J. (2011). Dynamic compressive loading of image-guided tissue engineered meniscal constructs. Journal of Biomechanics, 44(3), 509–516. https://doi.org/10.1016/j.jbiomech.2010.09.017
  9. von Lewinski, G., & Wirth, C. J. (2010). Basic Science. In The Meniscus (pp. 303–313). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-02450-4_39
  10. Nomura, K., Fukada, K., Azuma, T., Hamasaki, T., Sakoda, S., & Nomura, T. (2009). A quantitative characterization of postural sway during human quiet standing using a thin pressure distribution measurement system. Gait & Posture, 29(4), 654–657. https://doi.org/10.1016/j.gaitpost.2009.02.001
  11. Lewinski, G. (2008). Allogene Meniskustransplantation. Der Orthopäde, 37(8), 743–748. https://doi.org/10.1007/s00132-008-1268-7
  12. Lubowitz, J. H., Verdonk, P. C. M., Reid, J. B., & Verdonk, R. (2007). Meniscus allograft transplantation: a current concepts review. Knee Surgery, Sports Traumatology, Arthroscopy, 15(5), 476–492. https://doi.org/10.1007/s00167-006-0216-5