Physical aspects of scintigraphybased dosimetry for nuclear medicine therapy
Description
SummaryIn nuclear medicine therapy the treatment of tumours by radiation exposure from internally deposited labelled antibodies or labelled peptides is currently an active field of investigation. To permit the efficient delivery of high amounts of radiation dose to tumours while limiting the radiation dose to critical organs dosimetry calculations have to be performed. These are relying on scintigraphic data being input to the well known MIRD formalism.This paper focuses on the methods and the difficulties associated with the scintigraphic determination of organ kinetics. The physical properties of the well-known scintigraphic imaging modalities, PET, SPECT and planar scintigraphy, are discussed thereby taking into account the properties of the appropriate radionuclides currently being available for therapy and dosimetry. Several arguments are given and disputed for the limited clinical use of PET and SPECT in dosimetry and the ongoing preference of planar whole-body imaging as the method of choice. The quantitative restrictions still inherent to this method are also discussed in detail. Procedural recommendations are proposed covering all processes related to data acquisition, data correction and data analysis which finally lead to reliable estimations of organ dose.
Additional details
Identifiers
- OpenAlex
- W2081974592
- PMID
- 20505893
- URL
- http://www.thieme-connect.de/DOI/DOI?10.3413/nukmed-0283
Dates
- Issued
-
2010
Citations
- Budiansah, I., Hardiansyah, D., Riana, A., Pawiro, S. A., Beer, A. J., & Glatting, G. (2025). Accuracy and precision analyses of single-time-point dosimetry utilising physiologically-based pharmacokinetic modelling and non-linear mixed-effects modelling. EJNMMI Physics, 12(1). https://doi.org/10.1186/s40658-025-00726-7
- Hardiansyah, D., Riana, A., Beer, A. J., & Glatting, G. (2023). Single-time-point estimation of absorbed doses in PRRT using a non-linear mixed-effects model. Zeitschrift Für Medizinische Physik, 33(1), 70–81. https://doi.org/10.1016/j.zemedi.2022.06.004
- Khalil, M. M. (2021). Internal Radiation Dosimetry. In Basic Sciences of Nuclear Medicine (pp. 203–228). Springer International Publishing. https://doi.org/10.1007/978-3-030-65245-6_9
- Rinscheid, A., Kletting, P., Eiber, M., Beer, A. J., & Glatting, G. (2019). Technical Note: Optimal sampling schedules for kidney dosimetry based on the hybrid planar/SPECT method in 177Lu‐PSMA therapy. Medical Physics, 46(12), 5861–5866. https://doi.org/10.1002/mp.13846
- Hardiansyah, D., Guo, W., Attarwala, A. A., Kletting, P., Mottaghy, F. M., & Glatting, G. (2017). Treatment planning in PRRT based on simulated PET data and a PBPK model. Nuklearmedizin, 56(01), 23–30. https://doi.org/10.3413/nukmed-0819-16-04
- Ritt, P., & Kuwert, T. (2012). Quantitative SPECT/CT. In Recent Results in Cancer Research (pp. 313–330). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-10853-2_10
- Römer, W. (2012). SPECT/CT – Technische Aspekte und Optimierungsmöglichkeiten. Der Radiologe, 52(7), 608–614. https://doi.org/10.1007/s00117-011-2268-x
- Rosenbaum-Krumme, S., Nagarajah, J., Ruhlmann, M., Bockisch, A., & Jentzen, W. (2012). 124I-PET/CT images of differentiated thyroid cancer patients. Nuklearmedizin, 51(06), 213–216. https://doi.org/10.3413/nukmed-0481-12-02
- Wierts, R., de Pont, C. D. J. M., Brans, B., Mottaghy, F. M., & Kemerink, G. J. (2011). Dosimetry in molecular nuclear therapy. Methods, 55(3), 196–202. https://doi.org/10.1016/j.ymeth.2011.09.016
- Parach, A. A., & Rajabi, H. (2011). A comparison between GATE4 results and MCNP4B published data for internal radiation dosimetry. Nuklearmedizin, 50(03), 122–133. https://doi.org/10.3413/nukmed-0363-10-10
- Laßmann, M. (2011). Von der effektiven Dosis in der Diagnostik zur patienten - spezifischen Dosimetrie in der nuklearmedizinischen Therapie. Nuklearmedizin, 50(06), 221–223. https://doi.org/10.3413/nukmed-2011060001