Long-Term Evaluation of a Fully Magnetically Levitated Circulatory Support Device for Advanced Heart Failure—Two-Year Results from The Heartmate 3 CE Mark Study
Authors/Creators
-
1.
Medizinische Hochschule Hannover
- 2. National Research Cardiac Surgery Center , Astana ,
-
3.
University of Vienna
-
4.
Deutsches Herzzentrum der Charité
-
5.
Leipzig Heart Institute
-
6.
Toronto General Hospital
- 7. Thoracic and Cardiovascular Surgery Clinic , Bad Oeynhausen ,
- 8. University Heart Center Freiburg-Bad Krozingen, Medical Faculty, Albert Ludwigs-University , Freiburg ,
-
9.
The Alfred Hospital
-
10.
Abbott (United States)
-
11.
Institute of Clinical and Experimental Medicine
Description
Abstract Aim This study aimed to assess safety and outcomes of patients, 2 years after implantation with the HeartMate 3 Left Ventricular Assist System. Methods and results This study included 50 adults with New York Heart Association (NYHA) class IIIB or IV symptoms or American College of Cardiology/American Heart Association stage D heart failure with an ejection fraction ≤25% and a cardiac index ≤2.2 L/min/m2 without inotropes, or inotrope-dependent with optimal medical management, or listed for heart transplant. The median duration of left ventricular assist device support was 694 days (range: 19–833 days). At baseline, cardiac index was 1.8 ±0.5 L/min/m2, 58% of patients were receiving inotropes, and 92% were INTERMACS profiles 2–4. At 2 years, Kaplan–Meier survival was 74 ±6%, 5 (10%) patients were transplanted, and 32 patients (64%) remain with support. Adverse event rates include bleeding requiring surgery (16%), gastrointestinal bleeding (20%), driveline infection (24%), ischaemic stroke (16%), haemorrhagic stroke (8%), right heart failure (14%), and outflow graft thrombosis (2%). Notably, no haemolysis, pump thrombosis, or pump malfunction events occurred. At 2 years, 47% of patients remained in NYHA class I and 41% in NYHA class II (P <0.0001). From baseline to 2 years, the mean six-minute walk distance increased from 239 m to 347 m (P <0.0001), and the mean EQ-5D quality of life score improved from 48.2 to 70.6 (P < 0.0001). Conclusions Two years post-HeartMate 3 implantation, results show expected and acceptable survival, enhanced haemocompatibility, improved patient functional status and quality of life. This corroborates the success of HeartMate 3 since its first-in-man implantation case in Germany. ClinicalTrials.gov: NCT02170363.
Additional details
Identifiers
- OpenAlex
- W2883188598
- PMID
- 30052304
- URL
- https://academic.oup.com/eurjhf/article/21/1/90/8408143
Dates
- Issued
-
July 27, 2018
References
- John, R., Naka, Y., Smedira, N. G., Starling, R., Jorde, U., Eckman, P., Farrar, D. J., & Pagani, F. D. (2011). Continuous Flow Left Ventricular Assist Device Outcomes in Commercial Use Compared With the Prior Clinical Trial. The Annals of Thoracic Surgery, 92(4), 1406–1413. https://doi.org/10.1016/j.athoracsur.2011.05.080
- Kirklin, J. K., Pagani, F. D., Kormos, R. L., Stevenson, L. W., Blume, E. D., Myers, S. L., Miller, M. A., Baldwin, J. T., Young, J. B., & Naftel, D. C. (2017). Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. The Journal of Heart and Lung Transplantation, 36(10), 1080–1086. https://doi.org/10.1016/j.healun.2017.07.005
- Bourque, K., Cotter, C., Dague, C., Harjes, D., Dur, O., Duhamel, J., Spink, K., Walsh, K., & Burke, E. (2016). Design Rationale and Preclinical Evaluation of the HeartMate 3 Left Ventricular Assist System for Hemocompatibility. ASAIO Journal, 62(4), 375–383. https://doi.org/10.1097/mat.0000000000000388
- Uriel, N., Colombo, P. C., Cleveland, J. C., Long, J. W., Salerno, C., Goldstein, D. J., Patel, C. B., Ewald, G. A., Tatooles, A. J., Silvestry, S. C., John, R., Caldeira, C., Jeevanandam, V., Boyle, A. J., Sundareswaran, K. S., Sood, P., & Mehra, M. R. (2017). Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months. Circulation, 135(21), 2003–2012. https://doi.org/10.1161/circulationaha.117.028303
- Netuka, I., Kvasnička, T., Kvasnička, J., Hrachovinová, I., Ivák, P., Mareček, F., Bílková, J., Malíková, I., Jančová, M., Malý, J., Sood, P., Sundareswaran, K. S., Connors, J. M., & Mehra, M. R. (2016). Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure. The Journal of Heart and Lung Transplantation, 35(7), 860–867. https://doi.org/10.1016/j.healun.2016.05.019
- Krabatsch, T., Netuka, I., Schmitto, J. D., Zimpfer, D., Garbade, J., Rao, V., Morshuis, M., Beyersdorf, F., Marasco, S., Damme, L., & Pya, Y. (2017). Heartmate 3 fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure –1 year results from the Ce mark trial. Journal of Cardiothoracic Surgery, 12(1). https://doi.org/10.1186/s13019-017-0587-3
- Zimpfer, D., Netuka, I., Schmitto, J. D., Pya, Y., Garbade, J., Morshuis, M., Beyersdorf, F., Marasco, S., Rao, V., Damme, L., Sood, P., & Krabatsch, T. (2016). Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes. European Journal of Cardio-Thoracic Surgery, 50(3), 548–554. https://doi.org/10.1093/ejcts/ezw169
- Netuka, I., Sood, P., Pya, Y., Zimpfer, D., Krabatsch, T., Garbade, J., Rao, V., Morshuis, M., Marasco, S., Beyersdorf, F., Damme, L., & Schmitto, J. D. (2015). Fully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF. Journal of the American College of Cardiology, 66(23), 2579–2589. https://doi.org/10.1016/j.jacc.2015.09.083
- Schmitto, J. D., Hanke, J. S., Rojas, S. V., Avsar, M., & Haverich, A. (2015). First implantation in man of a new magnetically levitated left ventricular assist device (HeartMate III). The Journal of Heart and Lung Transplantation, 34(6), 858–860. https://doi.org/10.1016/j.healun.2015.03.001
- Schulz, A., Stepanenko, A., & Krabatsch, T. (2016). HeartMate 3 implantation via left lateral thoracotomy with outflow graft anastomosis to the descending aorta. The Journal of Heart and Lung Transplantation, 35(5), 690–692. https://doi.org/10.1016/j.healun.2016.01.004
- Kirklin, J. K., Cantor, R., Mohacsi, P., Gummert, J., De By, T., Hannan, M. M., Kormos, R. L., Schueler, S., Lund, L. H., Nakatani, T., Taylor, R., & Lannon, J. (2016). First Annual IMACS Report: A global International Society for Heart and Lung Transplantation Registry for Mechanical Circulatory Support. The Journal of Heart and Lung Transplantation, 35(4), 407–412. https://doi.org/10.1016/j.healun.2016.01.002
- Kirklin, J. K., Pagani, F. D., Kormos, R. L., Stevenson, L. W., Blume, E. D., Myers, S. L., Miller, M. A., Baldwin, J. T., Young, J. B., & Naftel, D. C. (2017). Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. The Journal of Heart and Lung Transplantation, 36(10), 1080–1086. https://doi.org/10.1016/j.healun.2017.07.005
- Mehra, M. R., Goldstein, D. J., Uriel, N., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C., Walsh, M. N., Milano, C. A., Patel, C. B., Ewald, G. A., Itoh, A., Dean, D., Krishnamoorthy, A., Cotts, W. G., Tatooles, A. J., Jorde, U. P., Bruckner, B. A., Estep, J. D., Jeevanandam, V., … Naka, Y. (2018). Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. New England Journal of Medicine, 378(15), 1386–1395. https://doi.org/10.1056/nejmoa1800866
- Mehra, M. R., Stewart, G. C., & Uber, P. A. (2014). The vexing problem of thrombosis in long-term mechanical circulatory support. The Journal of Heart and Lung Transplantation, 33(1), 1–11. https://doi.org/10.1016/j.healun.2013.12.002
- Starling, R. C., Moazami, N., Silvestry, S. C., Ewald, G., Rogers, J. G., Milano, C. A., Rame, J. E., Acker, M. A., Blackstone, E. H., Ehrlinger, J., Thuita, L., Mountis, M. M., Soltesz, E. G., Lytle, B. W., & Smedira, N. G. (2014). Unexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis. New England Journal of Medicine, 370(1), 33–40. https://doi.org/10.1056/nejmoa1313385
- Levin, A. P., Uriel, N., Takayama, H., Mody, K. P., Ota, T., Yuzefpolskaya, M., Colombo, P. C., Garan, A. R., Dionizovik-Dimanovski, M., Sladen, R. N., Naka, Y., & Jorde, U. P. (2015). Device Exchange in HeartMate II Recipients: Long-Term Outcomes and Risk of Thrombosis Recurrence. ASAIO Journal, 61(2), 144–149. https://doi.org/10.1097/mat.0000000000000170
- McCarthy, F. H., Kobrin, D., Rame, J. E., Groeneveld, P. W., McDermott, K. M., Atluri, P., Acker, M. A., & Desai, N. D. (2015). Increasing Frequency of Left Ventricular Assist Device Exchanges in the United States. The Annals of Thoracic Surgery, 100(5), 1660–1665. https://doi.org/10.1016/j.athoracsur.2015.04.072
- Soleimani, B., Stephenson, E. R., Price, L. C., El-Banayosy, A., & Pae, W. E. (2015). Clinical Experience With Sternotomy Versus Subcostal Approach for Exchange of HeartMate II Left Ventricular Assist Device. The Annals of Thoracic Surgery, 100(5), 1577–1580. https://doi.org/10.1016/j.athoracsur.2015.05.033
- Kirklin, J. K., Naftel, D. C., Pagani, F. D., Kormos, R. L., Myers, S., Acker, M. A., Rogers, J., Slaughter, M. S., & Stevenson, L. W. (2015). Pump thrombosis in the Thoratec HeartMate II device: An update analysis of the INTERMACS Registry. The Journal of Heart and Lung Transplantation, 34(12), 1515–1526. https://doi.org/10.1016/j.healun.2015.10.024
- Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., Najarian, K. B., Bhat, G., Aaronson, K. D., & Boyce, S. W. (2014). An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. The Journal of Heart and Lung Transplantation, 33(1), 23–34. https://doi.org/10.1016/j.healun.2013.12.001
- Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., Gregoric, I. D., Mallidi, H., Leadley, K., Aaronson, K. D., Frazier, O. H., & Milano, C. A. (2017). Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. New England Journal of Medicine, 376(5), 451–460. https://doi.org/10.1056/nejmoa1602954
- Mehra, M. R., Naka, Y., Uriel, N., Goldstein, D. J., Cleveland, J. C., Colombo, P. C., Walsh, M. N., Milano, C. A., Patel, C. B., Jorde, U. P., Pagani, F. D., Aaronson, K. D., Dean, D. A., McCants, K., Itoh, A., Ewald, G. A., Horstmanshof, D., Long, J. W., & Salerno, C. (2017). A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. New England Journal of Medicine, 376(5), 440–450. https://doi.org/10.1056/nejmoa1610426
- Meyer, A. L., Malehsa, D., Bara, C., Budde, U., Slaughter, M. S., Haverich, A., & Strueber, M. (2010). Acquired von Willebrand Syndrome in Patients With an Axial Flow Left Ventricular Assist Device. Circulation: Heart Failure, 3(6), 675–681. https://doi.org/10.1161/circheartfailure.109.877597
- Uriel, N., Pak, S.-W., Jorde, U. P., Jude, B., Susen, S., Vincentelli, A., Ennezat, P.-V., Cappleman, S., Naka, Y., & Mancini, D. (2010). Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of Transplantation. Journal of the American College of Cardiology, 56(15), 1207–1213. https://doi.org/10.1016/j.jacc.2010.05.016
- Wever-Pinzon, O., Selzman, C. H., Drakos, S. G., Saidi, A., Stoddard, G. J., Gilbert, E. M., Labedi, M., Reid, B. B., Davis, E. S., Kfoury, A. G., Li, D. Y., Stehlik, J., & Bader, F. (2013). Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II. Circulation: Heart Failure, 6(3), 517–526. https://doi.org/10.1161/circheartfailure.112.000206
1–25 of 41
Citations
- Mansouri, H., Kemerli, M., MacIver, R., & Amili, O. (2026). Embolic Transport in LVAD Outflow: An Experimental Study Using Patient-Specific and Idealized Aortic Models. Annals of Biomedical Engineering, 54(11), 4094–4114. https://doi.org/10.1007/s10439-026-04136-3
- Liu, S.-H., Tsai, C.-S., Tsai, Y.-T., Lin, C.-Y., Ke, H.-Y., Lin, Y.-C., Chen, J.-L., Yang, H.-Y., Chien, W.-C., Weng, T.-H., & Hsu, P.-S. (2026). Efficacy of HeartMate 3 ventricular assist devices reimbursed by National Health Insurance: Retrospective analysis from a single center in Taiwan. Asian Journal of Surgery, 49(3), 1308–1315. https://doi.org/10.1016/j.asjsur.2025.10.065
- Cinkajzlova, A., Kasperova, B. J., Ivak, P., Netuka, I., Melenovsky, V., Mrazova, L. S., Stranecky, V., Mraz, M., Stemberkova Hubackova, S., & Haluzik, M. (2026). SGLT2 inhibitor therapy is associated with IL-10/TGF-α/sVEGFR3 signalling and adipose tissue remodelling in advanced heart failure. Journal of Molecular and Cellular Cardiology Plus, 17, 100860. https://doi.org/10.1016/j.jmccpl.2026.100860
- de La Bourdonnaye, C., Dib, N., Buschiazzo, A., Aymami, M., Charton, M., Flécher, E., & Tomasi, J. (2026). Assistance circulatoire mécanique de longue durée. EMC - Techniques chirurgicales - Thorax, 43(1), 1–12. https://doi.org/10.1016/s1241-8226(25)49817-x
- Krommenhoek, J. F., Janssen, E., den Exter, P. L., van der Horst, S. F. B., Beeres, S. L. M. A., Hjortnaes, J., Palmen, M., Klok, F. A., van Rein, N., Fiocco, M., Jukema, W., & Tops, L. F. (2026). Incidence of Recurrent Major Bleeding and its Impact on Survival in LVAD Patients: A Multistate Analysis. TH Open, 10(CP). https://doi.org/10.1055/a-2976-7540
- Hlavacek, D., Cinkajzlova, A., Kollar, M., Kasperova, B. J., Melenovsky, V., Mraz, M., Haluzik, M., Ivak, P., & Stemberkova Hubackova, S. (2026). Impact of a durable left ventricular assist device on inflammation and cardiac remodelling in subjects with advanced heart failure. Open Heart, 13(2), e004189. https://doi.org/10.1136/openhrt-2026-004189
- Wang, S., Wang, Y., Zhang, J., Yu, S., Kong, F., Zhou, C., & Dong, N. (2025). Implantation of integrated magnetically levitated biventricular assist devices (DuoCor) – a single-center clinical experience. International Journal of Surgery, 111(10), 6743–6754. https://doi.org/10.1097/js9.0000000000002879
- Qiu, Z., Song, X., Shi, H., Zhang, X., Chen, W., Wu, Y., & Chen, X. (2025). Safety and Efficacy of the Corheart 6 Left Ventricular Assist System. ASAIO Journal. https://doi.org/10.1097/mat.0000000000002554
- Hasan, R., Abou El Ala, A., Chang, A., & Colvin, M. (2024). Future Innovations Designed to Reduce Mortality and Morbidity of Mechanical Circulatory Support. In Mechanical Circulatory Support (pp. 1–12). Springer Nature Switzerland. https://doi.org/10.1007/978-3-030-86172-8_59-1
- Hasan, M., & Akamine, C. (2024). Electronic Control System for the Left Ventricular Assistance Device. 2024 4th Interdisciplinary Conference on Electrics and Computer (INTCEC), 1–6. https://doi.org/10.1109/intcec61833.2024.10602850
- Nair, S. S., Nagesh, D. S., Shenoy, S. J., & Harikrishnan, S. (2024). Performance evaluation of an automatically controlled transcutaneous energy transfer system powering left ventricular assist device. Artificial Organs, 49(3), 390–400. https://doi.org/10.1111/aor.14892
- Viana, P., Lopes, L. M., Cabral, T. D. D., Persson, J., Tapioca, V. de O., Freire, C. V. S., Relvas, J. H., Mesquita, Y., Marques, I. R., & Gomes, W. F. (2024). Warfarin and Aspirin Versus Warfarin Alone in Patients With HeartMate 3 Left Ventricular Assist Device: A Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology, 48(1), 53–58. https://doi.org/10.1111/pace.15110
- https://doi.org/10.3390/fluids9070157
- https://doi.org/10.57187/s.3529
- Ganapathi, A. M., Salerno, C. T., & Mokadam, N. A. (2023, September 8). Left Ventricular Assist Devices: Description of Available Technologies. In Textbook of Transplantation and Mechanical Support for End‐Stage Heart and Lung Disease (pp. 691–705). Wiley. https://doi.org/10.1002/9781119633884.ch50
- George, T. J., Kabra, N., DiMaio, J. M., Rawitscher, D. A., & Afzal, A. (2023). The Impact of MOMENTUM 3 Trial Eligibility on Left Ventricular Assist Device Outcomes: A Real-World Experience. Journal of Surgical Research, 287, 40–46. https://doi.org/10.1016/j.jss.2023.01.015
- Schmitto, J. D., Shaw, S., Garbade, J., Gustafsson, F., Morshuis, M., Zimpfer, D., Lavee, J., Pya, Y., Berchtold-Herz, M., Wang, A., Gazzola, C., Potapov, E., & Saeed, D. (2023). Fully magnetically centrifugal left ventricular assist device and long-term outcomes: the ELEVATE registry. European Heart Journal, 45(8), 613–625. https://doi.org/10.1093/eurheartj/ehad658
- https://doi.org/10.23736/s0021-9509.22.12445-6
- https://doi.org/10.3390/app14010284
- Jakus, N., Brugts, J. J., Claggett, B., Timmermans, P., Pouleur, A., Rubiś, P., Van Craenenbroeck, E. M., Gaizauskas, E., Barge‐Caballero, E., Paolillo, S., Grundmann, S., D'Amario, D., Braun, O. Ö., Gkouziouta, A., Meyns, B., Droogne, W., Wierzbicki, K., Holcman, K., Planinc, I., … registry, P. (2022). Improved survival of left ventricular assist device carriers in Europe according to implantation eras: results from the PCHF‐VAD registry. European Journal of Heart Failure, 24(7), 1305–1315. https://doi.org/10.1002/ejhf.2526
- Kourliouros, A., & Tsui, S. (2022). Quality of Life Following the Use of Mechanical Circulatory Support Devices. In Patient Reported Outcomes and Quality of Life in Cardiovascular Interventions (pp. 9–16). Springer International Publishing. https://doi.org/10.1007/978-3-031-09815-4_2
- Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Zimpfer, D. (2022). HVAD to HeartMate 3 Left Ventricular Assist Device Exchange: Best Practices Recommendations. The Annals of Thoracic Surgery, 113(6), 1770–1777. https://doi.org/10.1016/j.athoracsur.2021.11.078
- Vidula, H., Takeda, K., Estep, J. D., Silvestry, S. C., Milano, C., Cleveland, J. C., Goldstein, D. J., Uriel, N., Kormos, R. L., Dirckx, N., & Mehra, M. R. (2022). Hospitalization Patterns and Impact of a Magnetically-Levitated Left Ventricular Assist Device in the MOMENTUM 3 Trial. JACC: Heart Failure, 10(7), 470–481. https://doi.org/10.1016/j.jchf.2022.03.007
- Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Zimpfer, D. (2022). HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations. The Journal of Thoracic and Cardiovascular Surgery, 163(6), 2120–2127.e5. https://doi.org/10.1016/j.jtcvs.2021.11.085
- Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Daniel, Z. (2022). HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations. European Journal of Cardio-Thoracic Surgery, 62(1), Article ezac169. https://doi.org/10.1093/ejcts/ezac169
1–25 of 83