Published July 27, 2018 | Journal article | Version v1 | https://doi.org/10.1002/ejhf.1284

Long-Term Evaluation of a Fully Magnetically Levitated Circulatory Support Device for Advanced Heart Failure—Two-Year Results from The Heartmate 3 CE Mark Study

Description

Abstract Aim This study aimed to assess safety and outcomes of patients, 2 years after implantation with the HeartMate 3 Left Ventricular Assist System. Methods and results This study included 50 adults with New York Heart Association (NYHA) class IIIB or IV symptoms or American College of Cardiology/American Heart Association stage D heart failure with an ejection fraction ≤25% and a cardiac index ≤2.2 L/min/m2 without inotropes, or inotrope-dependent with optimal medical management, or listed for heart transplant. The median duration of left ventricular assist device support was 694 days (range: 19–833 days). At baseline, cardiac index was 1.8 ±0.5 L/min/m2, 58% of patients were receiving inotropes, and 92% were INTERMACS profiles 2–4. At 2 years, Kaplan–Meier survival was 74 ±6%, 5 (10%) patients were transplanted, and 32 patients (64%) remain with support. Adverse event rates include bleeding requiring surgery (16%), gastrointestinal bleeding (20%), driveline infection (24%), ischaemic stroke (16%), haemorrhagic stroke (8%), right heart failure (14%), and outflow graft thrombosis (2%). Notably, no haemolysis, pump thrombosis, or pump malfunction events occurred. At 2 years, 47% of patients remained in NYHA class I and 41% in NYHA class II (P <0.0001). From baseline to 2 years, the mean six-minute walk distance increased from 239 m to 347 m (P <0.0001), and the mean EQ-5D quality of life score improved from 48.2 to 70.6 (P < 0.0001). Conclusions Two years post-HeartMate 3 implantation, results show expected and acceptable survival, enhanced haemocompatibility, improved patient functional status and quality of life. This corroborates the success of HeartMate 3 since its first-in-man implantation case in Germany. ClinicalTrials.gov: NCT02170363.

Additional details

Dates

Issued
July 27, 2018

References

  1. John, R., Naka, Y., Smedira, N. G., Starling, R., Jorde, U., Eckman, P., Farrar, D. J., & Pagani, F. D. (2011). Continuous Flow Left Ventricular Assist Device Outcomes in Commercial Use Compared With the Prior Clinical Trial. The Annals of Thoracic Surgery, 92(4), 1406–1413. https://doi.org/10.1016/j.athoracsur.2011.05.080
  2. Kirklin, J. K., Pagani, F. D., Kormos, R. L., Stevenson, L. W., Blume, E. D., Myers, S. L., Miller, M. A., Baldwin, J. T., Young, J. B., & Naftel, D. C. (2017). Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. The Journal of Heart and Lung Transplantation, 36(10), 1080–1086. https://doi.org/10.1016/j.healun.2017.07.005
  3. Bourque, K., Cotter, C., Dague, C., Harjes, D., Dur, O., Duhamel, J., Spink, K., Walsh, K., & Burke, E. (2016). Design Rationale and Preclinical Evaluation of the HeartMate 3 Left Ventricular Assist System for Hemocompatibility. ASAIO Journal, 62(4), 375–383. https://doi.org/10.1097/mat.0000000000000388
  4. Uriel, N., Colombo, P. C., Cleveland, J. C., Long, J. W., Salerno, C., Goldstein, D. J., Patel, C. B., Ewald, G. A., Tatooles, A. J., Silvestry, S. C., John, R., Caldeira, C., Jeevanandam, V., Boyle, A. J., Sundareswaran, K. S., Sood, P., & Mehra, M. R. (2017). Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months. Circulation, 135(21), 2003–2012. https://doi.org/10.1161/circulationaha.117.028303
  5. Netuka, I., Kvasnička, T., Kvasnička, J., Hrachovinová, I., Ivák, P., Mareček, F., Bílková, J., Malíková, I., Jančová, M., Malý, J., Sood, P., Sundareswaran, K. S., Connors, J. M., & Mehra, M. R. (2016). Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure. The Journal of Heart and Lung Transplantation, 35(7), 860–867. https://doi.org/10.1016/j.healun.2016.05.019
  6. Krabatsch, T., Netuka, I., Schmitto, J. D., Zimpfer, D., Garbade, J., Rao, V., Morshuis, M., Beyersdorf, F., Marasco, S., Damme, L., & Pya, Y. (2017). Heartmate 3 fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure –1 year results from the Ce mark trial. Journal of Cardiothoracic Surgery, 12(1). https://doi.org/10.1186/s13019-017-0587-3
  7. Zimpfer, D., Netuka, I., Schmitto, J. D., Pya, Y., Garbade, J., Morshuis, M., Beyersdorf, F., Marasco, S., Rao, V., Damme, L., Sood, P., & Krabatsch, T. (2016). Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes. European Journal of Cardio-Thoracic Surgery, 50(3), 548–554. https://doi.org/10.1093/ejcts/ezw169
  8. Netuka, I., Sood, P., Pya, Y., Zimpfer, D., Krabatsch, T., Garbade, J., Rao, V., Morshuis, M., Marasco, S., Beyersdorf, F., Damme, L., & Schmitto, J. D. (2015). Fully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF. Journal of the American College of Cardiology, 66(23), 2579–2589. https://doi.org/10.1016/j.jacc.2015.09.083
  9. Schmitto, J. D., Hanke, J. S., Rojas, S. V., Avsar, M., & Haverich, A. (2015). First implantation in man of a new magnetically levitated left ventricular assist device (HeartMate III). The Journal of Heart and Lung Transplantation, 34(6), 858–860. https://doi.org/10.1016/j.healun.2015.03.001
  10. Schulz, A., Stepanenko, A., & Krabatsch, T. (2016). HeartMate 3 implantation via left lateral thoracotomy with outflow graft anastomosis to the descending aorta. The Journal of Heart and Lung Transplantation, 35(5), 690–692. https://doi.org/10.1016/j.healun.2016.01.004
  11. Kirklin, J. K., Cantor, R., Mohacsi, P., Gummert, J., De By, T., Hannan, M. M., Kormos, R. L., Schueler, S., Lund, L. H., Nakatani, T., Taylor, R., & Lannon, J. (2016). First Annual IMACS Report: A global International Society for Heart and Lung Transplantation Registry for Mechanical Circulatory Support. The Journal of Heart and Lung Transplantation, 35(4), 407–412. https://doi.org/10.1016/j.healun.2016.01.002
  12. Kirklin, J. K., Pagani, F. D., Kormos, R. L., Stevenson, L. W., Blume, E. D., Myers, S. L., Miller, M. A., Baldwin, J. T., Young, J. B., & Naftel, D. C. (2017). Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. The Journal of Heart and Lung Transplantation, 36(10), 1080–1086. https://doi.org/10.1016/j.healun.2017.07.005
  13. Mehra, M. R., Goldstein, D. J., Uriel, N., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C., Walsh, M. N., Milano, C. A., Patel, C. B., Ewald, G. A., Itoh, A., Dean, D., Krishnamoorthy, A., Cotts, W. G., Tatooles, A. J., Jorde, U. P., Bruckner, B. A., Estep, J. D., Jeevanandam, V., … Naka, Y. (2018). Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. New England Journal of Medicine, 378(15), 1386–1395. https://doi.org/10.1056/nejmoa1800866
  14. Mehra, M. R., Stewart, G. C., & Uber, P. A. (2014). The vexing problem of thrombosis in long-term mechanical circulatory support. The Journal of Heart and Lung Transplantation, 33(1), 1–11. https://doi.org/10.1016/j.healun.2013.12.002
  15. Starling, R. C., Moazami, N., Silvestry, S. C., Ewald, G., Rogers, J. G., Milano, C. A., Rame, J. E., Acker, M. A., Blackstone, E. H., Ehrlinger, J., Thuita, L., Mountis, M. M., Soltesz, E. G., Lytle, B. W., & Smedira, N. G. (2014). Unexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis. New England Journal of Medicine, 370(1), 33–40. https://doi.org/10.1056/nejmoa1313385
  16. Levin, A. P., Uriel, N., Takayama, H., Mody, K. P., Ota, T., Yuzefpolskaya, M., Colombo, P. C., Garan, A. R., Dionizovik-Dimanovski, M., Sladen, R. N., Naka, Y., & Jorde, U. P. (2015). Device Exchange in HeartMate II Recipients: Long-Term Outcomes and Risk of Thrombosis Recurrence. ASAIO Journal, 61(2), 144–149. https://doi.org/10.1097/mat.0000000000000170
  17. McCarthy, F. H., Kobrin, D., Rame, J. E., Groeneveld, P. W., McDermott, K. M., Atluri, P., Acker, M. A., & Desai, N. D. (2015). Increasing Frequency of Left Ventricular Assist Device Exchanges in the United States. The Annals of Thoracic Surgery, 100(5), 1660–1665. https://doi.org/10.1016/j.athoracsur.2015.04.072
  18. Soleimani, B., Stephenson, E. R., Price, L. C., El-Banayosy, A., & Pae, W. E. (2015). Clinical Experience With Sternotomy Versus Subcostal Approach for Exchange of HeartMate II Left Ventricular Assist Device. The Annals of Thoracic Surgery, 100(5), 1577–1580. https://doi.org/10.1016/j.athoracsur.2015.05.033
  19. Kirklin, J. K., Naftel, D. C., Pagani, F. D., Kormos, R. L., Myers, S., Acker, M. A., Rogers, J., Slaughter, M. S., & Stevenson, L. W. (2015). Pump thrombosis in the Thoratec HeartMate II device: An update analysis of the INTERMACS Registry. The Journal of Heart and Lung Transplantation, 34(12), 1515–1526. https://doi.org/10.1016/j.healun.2015.10.024
  20. Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., Najarian, K. B., Bhat, G., Aaronson, K. D., & Boyce, S. W. (2014). An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. The Journal of Heart and Lung Transplantation, 33(1), 23–34. https://doi.org/10.1016/j.healun.2013.12.001
  21. Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., Gregoric, I. D., Mallidi, H., Leadley, K., Aaronson, K. D., Frazier, O. H., & Milano, C. A. (2017). Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. New England Journal of Medicine, 376(5), 451–460. https://doi.org/10.1056/nejmoa1602954
  22. Mehra, M. R., Naka, Y., Uriel, N., Goldstein, D. J., Cleveland, J. C., Colombo, P. C., Walsh, M. N., Milano, C. A., Patel, C. B., Jorde, U. P., Pagani, F. D., Aaronson, K. D., Dean, D. A., McCants, K., Itoh, A., Ewald, G. A., Horstmanshof, D., Long, J. W., & Salerno, C. (2017). A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. New England Journal of Medicine, 376(5), 440–450. https://doi.org/10.1056/nejmoa1610426
  23. Meyer, A. L., Malehsa, D., Bara, C., Budde, U., Slaughter, M. S., Haverich, A., & Strueber, M. (2010). Acquired von Willebrand Syndrome in Patients With an Axial Flow Left Ventricular Assist Device. Circulation: Heart Failure, 3(6), 675–681. https://doi.org/10.1161/circheartfailure.109.877597
  24. Uriel, N., Pak, S.-W., Jorde, U. P., Jude, B., Susen, S., Vincentelli, A., Ennezat, P.-V., Cappleman, S., Naka, Y., & Mancini, D. (2010). Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of Transplantation. Journal of the American College of Cardiology, 56(15), 1207–1213. https://doi.org/10.1016/j.jacc.2010.05.016
  25. Wever-Pinzon, O., Selzman, C. H., Drakos, S. G., Saidi, A., Stoddard, G. J., Gilbert, E. M., Labedi, M., Reid, B. B., Davis, E. S., Kfoury, A. G., Li, D. Y., Stehlik, J., & Bader, F. (2013). Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II. Circulation: Heart Failure, 6(3), 517–526. https://doi.org/10.1161/circheartfailure.112.000206

1–25 of 41

Citations

  1. Mansouri, H., Kemerli, M., MacIver, R., & Amili, O. (2026). Embolic Transport in LVAD Outflow: An Experimental Study Using Patient-Specific and Idealized Aortic Models. Annals of Biomedical Engineering, 54(11), 4094–4114. https://doi.org/10.1007/s10439-026-04136-3
  2. Liu, S.-H., Tsai, C.-S., Tsai, Y.-T., Lin, C.-Y., Ke, H.-Y., Lin, Y.-C., Chen, J.-L., Yang, H.-Y., Chien, W.-C., Weng, T.-H., & Hsu, P.-S. (2026). Efficacy of HeartMate 3 ventricular assist devices reimbursed by National Health Insurance: Retrospective analysis from a single center in Taiwan. Asian Journal of Surgery, 49(3), 1308–1315. https://doi.org/10.1016/j.asjsur.2025.10.065
  3. Cinkajzlova, A., Kasperova, B. J., Ivak, P., Netuka, I., Melenovsky, V., Mrazova, L. S., Stranecky, V., Mraz, M., Stemberkova Hubackova, S., & Haluzik, M. (2026). SGLT2 inhibitor therapy is associated with IL-10/TGF-α/sVEGFR3 signalling and adipose tissue remodelling in advanced heart failure. Journal of Molecular and Cellular Cardiology Plus, 17, 100860. https://doi.org/10.1016/j.jmccpl.2026.100860
  4. de La Bourdonnaye, C., Dib, N., Buschiazzo, A., Aymami, M., Charton, M., Flécher, E., & Tomasi, J. (2026). Assistance circulatoire mécanique de longue durée. EMC - Techniques chirurgicales - Thorax, 43(1), 1–12. https://doi.org/10.1016/s1241-8226(25)49817-x
  5. Krommenhoek, J. F., Janssen, E., den Exter, P. L., van der Horst, S. F. B., Beeres, S. L. M. A., Hjortnaes, J., Palmen, M., Klok, F. A., van Rein, N., Fiocco, M., Jukema, W., & Tops, L. F. (2026). Incidence of Recurrent Major Bleeding and its Impact on Survival in LVAD Patients: A Multistate Analysis. TH Open, 10(CP). https://doi.org/10.1055/a-2976-7540
  6. Hlavacek, D., Cinkajzlova, A., Kollar, M., Kasperova, B. J., Melenovsky, V., Mraz, M., Haluzik, M., Ivak, P., & Stemberkova Hubackova, S. (2026). Impact of a durable left ventricular assist device on inflammation and cardiac remodelling in subjects with advanced heart failure. Open Heart, 13(2), e004189. https://doi.org/10.1136/openhrt-2026-004189
  7. Wang, S., Wang, Y., Zhang, J., Yu, S., Kong, F., Zhou, C., & Dong, N. (2025). Implantation of integrated magnetically levitated biventricular assist devices (DuoCor) – a single-center clinical experience. International Journal of Surgery, 111(10), 6743–6754. https://doi.org/10.1097/js9.0000000000002879
  8. Qiu, Z., Song, X., Shi, H., Zhang, X., Chen, W., Wu, Y., & Chen, X. (2025). Safety and Efficacy of the Corheart 6 Left Ventricular Assist System. ASAIO Journal. https://doi.org/10.1097/mat.0000000000002554
  9. Hasan, R., Abou El Ala, A., Chang, A., & Colvin, M. (2024). Future Innovations Designed to Reduce Mortality and Morbidity of Mechanical Circulatory Support. In Mechanical Circulatory Support (pp. 1–12). Springer Nature Switzerland. https://doi.org/10.1007/978-3-030-86172-8_59-1
  10. Hasan, M., & Akamine, C. (2024). Electronic Control System for the Left Ventricular Assistance Device. 2024 4th Interdisciplinary Conference on Electrics and Computer (INTCEC), 1–6. https://doi.org/10.1109/intcec61833.2024.10602850
  11. Nair, S. S., Nagesh, D. S., Shenoy, S. J., & Harikrishnan, S. (2024). Performance evaluation of an automatically controlled transcutaneous energy transfer system powering left ventricular assist device. Artificial Organs, 49(3), 390–400. https://doi.org/10.1111/aor.14892
  12. Viana, P., Lopes, L. M., Cabral, T. D. D., Persson, J., Tapioca, V. de O., Freire, C. V. S., Relvas, J. H., Mesquita, Y., Marques, I. R., & Gomes, W. F. (2024). Warfarin and Aspirin Versus Warfarin Alone in Patients With HeartMate 3 Left Ventricular Assist Device: A Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology, 48(1), 53–58. https://doi.org/10.1111/pace.15110
  13. https://doi.org/10.3390/fluids9070157
  14. https://doi.org/10.57187/s.3529
  15. Ganapathi, A. M., Salerno, C. T., & Mokadam, N. A. (2023, September 8). Left Ventricular Assist Devices: Description of Available Technologies. In Textbook of Transplantation and Mechanical Support for End‐Stage Heart and Lung Disease (pp. 691–705). Wiley. https://doi.org/10.1002/9781119633884.ch50
  16. George, T. J., Kabra, N., DiMaio, J. M., Rawitscher, D. A., & Afzal, A. (2023). The Impact of MOMENTUM 3 Trial Eligibility on Left Ventricular Assist Device Outcomes: A Real-World Experience. Journal of Surgical Research, 287, 40–46. https://doi.org/10.1016/j.jss.2023.01.015
  17. Schmitto, J. D., Shaw, S., Garbade, J., Gustafsson, F., Morshuis, M., Zimpfer, D., Lavee, J., Pya, Y., Berchtold-Herz, M., Wang, A., Gazzola, C., Potapov, E., & Saeed, D. (2023). Fully magnetically centrifugal left ventricular assist device and long-term outcomes: the ELEVATE registry. European Heart Journal, 45(8), 613–625. https://doi.org/10.1093/eurheartj/ehad658
  18. https://doi.org/10.23736/s0021-9509.22.12445-6
  19. https://doi.org/10.3390/app14010284
  20. Jakus, N., Brugts, J. J., Claggett, B., Timmermans, P., Pouleur, A., Rubiś, P., Van Craenenbroeck, E. M., Gaizauskas, E., Barge‐Caballero, E., Paolillo, S., Grundmann, S., D'Amario, D., Braun, O. Ö., Gkouziouta, A., Meyns, B., Droogne, W., Wierzbicki, K., Holcman, K., Planinc, I., … registry, P. (2022). Improved survival of left ventricular assist device carriers in Europe according to implantation eras: results from the PCHF‐VAD registry. European Journal of Heart Failure, 24(7), 1305–1315. https://doi.org/10.1002/ejhf.2526
  21. Kourliouros, A., & Tsui, S. (2022). Quality of Life Following the Use of Mechanical Circulatory Support Devices. In Patient Reported Outcomes and Quality of Life in Cardiovascular Interventions (pp. 9–16). Springer International Publishing. https://doi.org/10.1007/978-3-031-09815-4_2
  22. Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Zimpfer, D. (2022). HVAD to HeartMate 3 Left Ventricular Assist Device Exchange: Best Practices Recommendations. The Annals of Thoracic Surgery, 113(6), 1770–1777. https://doi.org/10.1016/j.athoracsur.2021.11.078
  23. Vidula, H., Takeda, K., Estep, J. D., Silvestry, S. C., Milano, C., Cleveland, J. C., Goldstein, D. J., Uriel, N., Kormos, R. L., Dirckx, N., & Mehra, M. R. (2022). Hospitalization Patterns and Impact of a Magnetically-Levitated Left Ventricular Assist Device in the MOMENTUM 3 Trial. JACC: Heart Failure, 10(7), 470–481. https://doi.org/10.1016/j.jchf.2022.03.007
  24. Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Zimpfer, D. (2022). HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations. The Journal of Thoracic and Cardiovascular Surgery, 163(6), 2120–2127.e5. https://doi.org/10.1016/j.jtcvs.2021.11.085
  25. Salerno, C. T., Hayward, C., Hall, S., Goldstein, D., Saeed, D., Schmitto, J., Kaczorowski, D., Molina, E., Zimpfer, D., Tsui, S., Soltesz, E., Pham, D. T., Mokadam, N. A., Kilic, A., Davis, E., Feller, E., Lorts, A., Silvestry, S., Slaughter, M. S., … Daniel, Z. (2022). HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations. European Journal of Cardio-Thoracic Surgery, 62(1), Article ezac169. https://doi.org/10.1093/ejcts/ezac169

1–25 of 83