Comparison of global and regional myocardial blood flow quantification using dynamic solid-state detector SPECT and Tc-99 m-sestamibi or Tc-99 m-tetrofosmin in a routine clinical setting
Authors/Creators
Description
Abstract Solid-state detector single photon emission computed tomography (SPECT) enables the acquisition of dynamic data for calculation of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Here, we report about our experiences on routine clinical use and robustness using Tc-99 m-sestamibi and Tc-99 m-tetrofosmin. 307 patients underwent dynamic list-mode myocardial perfusion imaging (MPI) and standard static MPI for clinical workup of coronary artery disease on a dedicated cardiac SPECT camera. After exclusion of 33 scans, 274 scans were eligible for MBF and MFR calculation using a 1‐tissue‐compartment model. Attenuation correction was performed for all patients using an external computed tomogram. Patients underwent stress-only scans, both stress and rest scans or rest-only scans using Tc-99 m-tetrofosmin or Tc-99 m-sestamibi. 30 patients without known cardiovascular comorbidities and without perfusion defect on static scans were compared in a sub analysis. Global stress myocardial blood flow (MBF) was significantly higher than rest MBF (2.3 vs. 1.1 ml/min/g; p < 0.001), and showed a high variability among individuals. Global myocardial flow reserve (MFR) was 2.1 (range 0.5–7.8). An analysis of 30 patients without known cardiovascular comorbidities yielded similar stress MBF measures for Tc-99 m-sestamibi and Tc-99 m-tetrofosmin (3.1 ± 1.2 vs. 2.8 ± 0.9 ml/min/g; p = 0.429). The use of attenuation correction lead to systematically lower MBF measures. Patients who underwent a one-day protocol had notably higher rest MBF (1.2 ± 0.5 vs. 1.0 ± 0.46 ml/min/g; p = 0.009) and consequently a lower MFR. Summed defect scores from standard static scans and presence of cardiovascular comorbidities negatively impacted MBF and MFR. Quantitative SPECT MBF and MFR in a clinical routine setting yields flow measures in range of expectation at an albeit wide range and is comprehensibly linked with results from standard static scan and patients history of cardiovascular diseases. Use of one-day protocols and attenuation correction systematically alters quantitative results. However, SPECT-derived MBF and MFR lack clinical reliability due to less validated reference ranges and high inter-individual variability. Graphical abstract
Additional details
Identifiers
- OpenAlex
- W4406969825
- PMID
- 39885112
- URL
- https://link.springer.com/10.1007/s10554-025-03339-4
Related works
- Is new version of
- 10.21203/rs.3.rs-5431655/v1 (DOI)
Funding
- Medizinische Hochschule Hannover (MHH)
Dates
- Issued
-
January 30, 2025
References
- Ziadi, M. C., deKemp, R. A., Williams, K. A., Guo, A., Chow, B. J. W., Renaud, J. M., Ruddy, T. D., Sarveswaran, N., Tee, R. E., & Beanlands, R. S. B. (2011). Impaired Myocardial Flow Reserve on Rubidium-82 Positron Emission Tomography Imaging Predicts Adverse Outcomes in Patients Assessed for Myocardial Ischemia. Journal of the American College of Cardiology, 58(7), 740–748. https://doi.org/10.1016/j.jacc.2011.01.065
- deKemp, R. A., Yoshinaga, K., & Beanlands, R. S. B. (2007). Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?. Journal of Nuclear Cardiology, 14(3), 380–397. https://doi.org/10.1016/j.nuclcard.2007.04.006
- Ziadi, M. C., deKemp, R. A., Williams, K., Guo, A., Renaud, J. M., Chow, B. J. W., Klein, R., Ruddy, T. D., Aung, M., Garrard, L., & Beanlands, R. S. B. (2012). Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease?. Journal of Nuclear Cardiology, 19(4), 670–680. https://doi.org/10.1007/s12350-011-9506-5
- Herzog, B. A., Husmann, L., Valenta, I., Gaemperli, O., Siegrist, P. T., Tay, F. M., Burkhard, N., Wyss, C. A., & Kaufmann, P. A. (2009). Long-Term Prognostic Value of 13N-Ammonia Myocardial Perfusion Positron Emission Tomography. Journal of the American College of Cardiology, 54(2), 150–156. https://doi.org/10.1016/j.jacc.2009.02.069
- Saraste, A., Kajander, S., Han, C., Nesterov, S. V., & Knuuti, J. (2012). PET: Is myocardial flow quantification a clinical reality?. Journal of Nuclear Cardiology, 19(5), 1044–1059. https://doi.org/10.1007/s12350-012-9588-8
- Camici, P. G., & Rimoldi, O. E. (2009). The Clinical Value of Myocardial Blood Flow Measurement. Journal of Nuclear Medicine, 50(7), 1076–1087. https://doi.org/10.2967/jnumed.108.054478
- Murthy, V. L., Naya, M., Foster, C. R., Hainer, J., Gaber, M., Di Carli, G., Blankstein, R., Dorbala, S., Sitek, A., Pencina, M. J., & Di Carli, M. F. (2011). Improved Cardiac Risk Assessment With Noninvasive Measures of Coronary Flow Reserve. Circulation, 124(20), 2215–2224. https://doi.org/10.1161/circulationaha.111.050427
- Valenta, I., Dilsizian, V., Quercioli, A., Ruddy, T. D., & Schindler, T. H. (2013). Quantitative PET/CT Measures of Myocardial Flow Reserve and Atherosclerosis for Cardiac Risk Assessment and Predicting Adverse Patient Outcomes. Current Cardiology Reports, 15(3). https://doi.org/10.1007/s11886-012-0344-0
- Storto, G., Sorrentino, A. R., Pellegrino, T., Liuzzi, R., Petretta, M., & Cuocolo, A. (2007). Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries. European Journal of Nuclear Medicine and Molecular Imaging, 34(8), 1156–1161. https://doi.org/10.1007/s00259-006-0333-x
- Gullberg, G. T., Reutter, B. W., Sitek, A., Maltz, J. S., & Budinger, T. F. (2010). Dynamic single photon emission computed tomography—basic principles and cardiac applications. Physics in Medicine and Biology, 55(20), R111–R191. https://doi.org/10.1088/0031-9155/55/20/r01
- Daniele, S., Nappi, C., Acampa, W., Storto, G., Pellegrino, T., Ricci, F., Xhoxhi, E., Porcaro, F., Petretta, M., & Cuocolo, A. (2011). Incremental prognostic value of coronary flow reserve assessed with single-photon emission computed tomography. Journal of Nuclear Cardiology, 18(4), 612–619. https://doi.org/10.1007/s12350-011-9345-4
- Hsu, B., Chen, F.-C., Wu, T.-C., Huang, W.-S., Hou, P.-N., Chen, C.-C., & Hung, G.-U. (2014). Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease. European Journal of Nuclear Medicine and Molecular Imaging, 41(12), 2294–2306. https://doi.org/10.1007/s00259-014-2881-9
- Shrestha, U., Sciammarella, M., Alhassen, F., Yeghiazarians, Y., Ellin, J., Verdin, E., Boyle, A., Seo, Y., Botvinick, E. H., & Gullberg, G. T. (2017). Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation. Journal of Nuclear Cardiology, 24(1), 268–277. https://doi.org/10.1007/s12350-015-0320-3
- Ben-Haim, S., Murthy, V. L., Breault, C., Allie, R., Sitek, A., Roth, N., Fantony, J., Moore, S. C., Park, M.-A., Kijewski, M., Haroon, A., Slomka, P., Erlandsson, K., Baavour, R., Zilberstien, Y., Bomanji, J., & Di Carli, M. F. (2013). Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study. Journal of Nuclear Medicine, 54(6), 873–879. https://doi.org/10.2967/jnumed.112.109652
- Ben Bouallègue, F., Roubille, F., Lattuca, B., Cung, T. T., Macia, J.-C., Gervasoni, R., Leclercq, F., & Mariano-Goulart, D. (2015). SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements. Journal of Nuclear Medicine, 56(11), 1712–1717. https://doi.org/10.2967/jnumed.114.143164
- Shiraishi, S., Sakamoto, F., Tsuda, N., Yoshida, M., Tomiguchi, S., Utsunomiya, D., Ogawa, H., & Yamashita, Y. (2015). Prediction of Left Main or 3-Vessel Disease Using Myocardial Perfusion Reserve on Dynamic Thallium-201 Single-Photon Emission Computed Tomography With a Semiconductor Gamma Camera. Circulation Journal, 79(3), 623–631. https://doi.org/10.1253/circj.cj-14-0932
- Wells, R. G., Marvin, B., Poirier, M., Renaud, J., deKemp, R. A., & Ruddy, T. D. (2017). Optimization of SPECT Measurement of Myocardial Blood Flow with Corrections for Attenuation, Motion, and Blood Binding Compared with PET. Journal of Nuclear Medicine, 58(12), 2013–2019. https://doi.org/10.2967/jnumed.117.191049
- Agostini, D., Roule, V., Nganoa, C., Roth, N., Baavour, R., Parienti, J.-J., Beygui, F., & Manrique, A. (2018). First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. European Journal of Nuclear Medicine and Molecular Imaging, 45(7), 1079–1090. https://doi.org/10.1007/s00259-018-3958-7
- de Souza, A. C. do A. H., Gonçalves, B. K. D., Tedeschi, A. L., & Lima, R. S. L. (2021). Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease. Journal of Nuclear Cardiology, 28(3), 876–884. https://doi.org/10.1007/s12350-019-01775-z
- Panjer, M., Dobrolinska, M., Wagenaar, N. R. L., & Slart, R. H. J. A. (2022). Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis. Journal of Nuclear Cardiology, 29(4), 1686–1697. https://doi.org/10.1007/s12350-021-02721-8
- Liga, R., Neglia, D., Kusch, A., Favilli, B., Giorgetti, A., & Gimelli, A. (2022). Prognostic Role of Dynamic CZT Imaging in CAD Patients. JACC: Cardiovascular Imaging, 15(3), 540–542. https://doi.org/10.1016/j.jcmg.2021.09.030
- Schindler, T. H., Fearon, W. F., Pelletier-Galarneau, M., Ambrosio, G., Sechtem, U., Ruddy, T. D., Patel, K. K., Bhatt, D. L., Bateman, T. M., Gewirtz, H., Shirani, J., Knuuti, J., Gropler, R. J., Chareonthaitawee, P., Slart, R. H. J. A., Windecker, S., Kaufmann, P. A., Abraham, M. R., Taqueti, V. R., … Dilsizian, V. (2023). Myocardial Perfusion PET for the Detection and Reporting of Coronary Microvascular Dysfunction. JACC: Cardiovascular Imaging, 16(4), 536–548. https://doi.org/10.1016/j.jcmg.2022.12.015
- Zavadovsky, K. V., Mochula, A. V., Maltseva, A. N., Boshchenko, A. A., Baev, A. E., Andreev, S. L., Nesterov, E. A., Liga, R., & Gimelli, A. (2022). The diagnostic value of SPECT CZT quantitative myocardial blood flow in high-risk patients. Journal of Nuclear Cardiology, 29(3), 1051–1063. https://doi.org/10.1007/s12350-020-02395-8
- Di Carli, M. F. (2023). Clinical Value of Positron Emission Tomography Myocardial Perfusion Imaging and Blood Flow Quantification. Cardiology Clinics, 41(2), 185–195. https://doi.org/10.1016/j.ccl.2023.01.007
- Murthy, V. L., Bateman, T. M., Beanlands, R. S., Berman, D. S., Borges-Neto, S., Chareonthaitawee, P., Cerqueira, M. D., deKemp, R. A., DePuey, E. G., Dilsizian, V., Dorbala, S., Ficaro, E. P., Garcia, E. V., Gewirtz, H., Heller, G. V., Lewin, H. C., Malhotra, S., Mann, A., Ruddy, T. D., … Di Carli, M. F. (2017). Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC. Journal of Nuclear Medicine, 59(2), 273–293. https://doi.org/10.2967/jnumed.117.201368
1–25 of 37