Skip to main
Flow and mass transfer prediction in anisotropic TPMS-structures as extracorporeal oxygenator membranes using reduced order modeling
Authors/Creators
-
Barbian, Kai P.1
-
Hirschwald, Lukas T.1
-
Linkhorst, John2, 1
-
Neidlin, Michael1
-
Steinseifer, Ulrich1
-
Wessling, Matthias
-
Wiegmann, Bettina3, 4
-
Jansen, Sebastian V.1
Additional details
- Extracorporeal membrane oxygenation (ECMO) in critically ill patients with coronavirus disease 2019 (COVID-19) pneumonia and acute respiratory distress syndrome (ARDS)
-
Oh, T. K., Cho, H.-W., Lee, H.-T., & Song, I.-A. (2021). Chronic respiratory disease and survival outcomes after extracorporeal membrane oxygenation. Respiratory Research, 22(1).
https://doi.org/10.1186/s12931-021-01796-8
-
Teber, O. O., Altinay, A. D., Mehrabani, S. A. N., Tasdemir, R. S., Zeytuncu, B., Genceli, E. A., Dulekgurgen, E., Pekkan, K., & Koyuncu, İ. (2022). Polymeric hollow fiber membrane oxygenators as artificial lungs: A review. Biochemical Engineering Journal, 180, 108340.
https://doi.org/10.1016/j.bej.2022.108340
-
Gartner, M. J., Wilhelm, C. R., Gage, K. L., Fabrizio, M. C., & Wagner, W. R. (2000). Modeling Flow Effects on Thrombotic Deposition in a Membrane Oxygenator. Artificial Organs, 24(1), 29–36.
https://doi.org/10.1046/j.1525-1594.2000.06384.x
-
Birkenmaier, C., Dornia, C., Lehle, K., Müller, T., Gruber, M., Philipp, A., & Krenkel, L. (2019). Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study. ASAIO Journal, 66(8), 922–928.
https://doi.org/10.1097/mat.0000000000001089
-
Kaesler, A., Rosen, M., Schmitz‐Rode, T., Steinseifer, U., & Arens, J. (2018). Computational Modeling of Oxygen Transfer in Artificial Lungs. Artificial Organs, 42(8), 786–799.
https://doi.org/10.1111/aor.13146
-
Lubnow, M., Philipp, A., Foltan, M., Bull Enger, T., Lunz, D., Bein, T., Haneya, A., Schmid, C., Riegger, G., Müller, T., Lehle, K., & Schäfer, A. (2014). Technical Complications during Veno-Venous Extracorporeal Membrane Oxygenation and Their Relevance Predicting a System-Exchange – Retrospective Analysis of 265 Cases. PLoS ONE, 9(12), e112316.
https://doi.org/10.1371/journal.pone.0112316
- Biohybrid lung development: Towards complete endothelialization of an assembled extracorporeal membrane oxygenator
-
Femmer, T., Kuehne, A. J. C., & Wessling, M. (2015). Estimation of the structure dependent performance of 3-D rapid prototyped membranes. Chemical Engineering Journal, 273, 438–445.
https://doi.org/10.1016/j.cej.2015.03.029
-
Hesselmann, F., Scherenberg, N., Bongartz, P., Djeljadini, S., Wessling, M., Cornelissen, C., Schmitz-Rode, T., Steinseifer, U., Jansen, S. V., & Arens, J. (2021). Structure-dependent gas transfer performance of 3D-membranes for artificial membrane lungs. Journal of Membrane Science, 634, 119371.
https://doi.org/10.1016/j.memsci.2021.119371
-
Hesselmann, F., Halwes, M., Bongartz, P., Wessling, M., Cornelissen, C., Schmitz-Rode, T., Steinseifer, U., Jansen, S. V., & Arens, J. (2022). TPMS-based membrane lung with locally-modified permeabilities for optimal flow distribution. Scientific Reports, 12(1).
https://doi.org/10.1038/s41598-022-11175-y
-
Taskin, M. E., Fraser, K. H., Zhang, T., Griffith, B. P., & Wu, Z. J. (2010). Micro-scale modeling of flow and oxygen transfer in hollow-fiber membrane bundle. Journal of Membrane Science, 362(1-2), 172–183.
https://doi.org/10.1016/j.memsci.2010.06.034
-
Hormes, M., Borchardt, R., Mager, I., Schmitz-Rode, T., Behr, M., & Steinseifer, U. (2011). A Validated Cfd Model to Predict O2 and Co2 Transfer Within Hollow Fiber Membrane Oxygenators. The International Journal of Artificial Organs, 34(3), 317–325.
https://doi.org/10.5301/ijao.2011.6494
-
Zhang, J., Nolan, T. D. C., Zhang, T., Griffith, B. P., & Wu, Z. J. (2007). Characterization of membrane blood oxygenation devices using computational fluid dynamics. Journal of Membrane Science, 288(1-2), 268–279.
https://doi.org/10.1016/j.memsci.2006.11.041
-
Hewitt, T. J., Hattler, B. G., & Federspiel, W. J. (1998). A Mathematical Model of Gas Exchange in an Intravenous Membrane Oxygenator. Annals of Biomedical Engineering, 26(1), 166–178.
https://doi.org/10.1114/1.53
-
Hesselmann, F., Arnemann, D., Bongartz, P., Wessling, M., Cornelissen, C., Schmitz‐Rode, T., Steinseifer, U., Jansen, S. V., & Arens, J. (2021). Three‐dimensional membranes for artificial lungs: Comparison of flow‐induced hemolysis. Artificial Organs, 46(3), 412–426.
https://doi.org/10.1111/aor.14081
-
Han, L., & Che, S. (2018). An Overview of Materials with Triply Periodic Minimal Surfaces and Related Geometry: From Biological Structures to Self‐Assembled Systems. Advanced Materials, 30(17).
https://doi.org/10.1002/adma.201705708
-
Tang, W., Zhou, H., Zeng, Y., Yan, M., Jiang, C., Yang, P., Li, Q., Li, Z., Fu, J., Huang, Y., & Zhao, Y. (2023). Analysis on the convective heat transfer process and performance evaluation of Triply Periodic Minimal Surface (TPMS) based on Diamond, Gyroid and Iwp. International Journal of Heat and Mass Transfer, 201, 123642.
https://doi.org/10.1016/j.ijheatmasstransfer.2022.123642
-
Roache, P. J. (1994). Perspective: A Method for Uniform Reporting of Grid Refinement Studies. Journal of Fluids Engineering, 116(3), 405–413.
https://doi.org/10.1115/1.2910291
-
Zakhary, B., Sheldrake, J., & Pellegrino, V. (2020). Extracorporeal membrane oxygenation and V/Q ratios: an ex vivo analysis of CO2 clearance within the Maquet Quadrox-iD oxygenator. Perfusion, 35(1_suppl), 29–33.
https://doi.org/10.1177/0267659120906767
-
Liu, H., Lan, L., Abrigo, J., Ip, H. L., Soo, Y., Zheng, D., Wong, K. S., Wang, D., Shi, L., Leung, T. W., & Leng, X. (2021). Corrigendum: Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients With Intracranial Arterial Stenosis. Frontiers in Physiology, 12.
https://doi.org/10.3389/fphys.2021.782647
-
Boyd, J., Buick, J. M., & Green, S. (2007). Analysis of the Casson and Carreau-Yasuda non-Newtonian blood models in steady and oscillatory flows using the lattice Boltzmann method. Physics of Fluids, 19(9).
https://doi.org/10.1063/1.2772250
- The design and application of upwind schemes on unstructured meshes
-
Majumdar, S. (1988). ROLE OF UNDERRELAXATION IN MOMENTUM INTERPOLATION FOR CALCULATION OF FLOW WITH NONSTAGGERED GRIDS. Numerical Heat Transfer, 13(1), 125–132.
https://doi.org/10.1080/10407788808913607
- Oxygenation and membrane oxygenators: Emergence evolution and progress in material development and process enhancement for biomedical applications
-
Hwang, S.-T., Tang, T. E. S., & Kammermeyer, K. (1971). Transport of dissolved oxygen through silicone rubber membrane. Journal of Macromolecular Science, Part B, 5(1), 1–10.
https://doi.org/10.1080/00222347108212517
-
Markov, D. A., Lillie, E. M., Garbett, S. P., & McCawley, L. J. (2013). Variation in diffusion of gases through PDMS due to plasma surface treatment and storage conditions. Biomedical Microdevices, 16(1), 91–96.
https://doi.org/10.1007/s10544-013-9808-2
-
Shiku, H., Saito, T., Wu, C.-C., Yasukawa, T., Yokoo, M., Abe, H., Matsue, T., & Yamada, H. (2006). Oxygen Permeability of Surface-modified Poly(dimethylsiloxane) Characterized by Scanning Electrochemical Microscopy. Chemistry Letters, 35(2), 234–235.
https://doi.org/10.1246/cl.2006.234
-
Kjeldsen, P. (1993). Evaluation of gas diffusion through plastic materials used in experimental and sampling equipment. Water Research, 27(1), 121–131.
https://doi.org/10.1016/0043-1354(93)90202-s
-
Charati, S. G., & Stern, S. A. (1998). Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations. Macromolecules, 31(16), 5529–5535.
https://doi.org/10.1021/ma980387e
-
Mäki, A.-J., Peltokangas, M., Kreutzer, J., Auvinen, S., & Kallio, P. (2015). Modeling carbon dioxide transport in PDMS-based microfluidic cell culture devices. Chemical Engineering Science, 137, 515–524.
https://doi.org/10.1016/j.ces.2015.06.065
-
He, G., Zhang, T., Zhang, J., Griffith, B. P., & Wu, Z. J. (2020). Model-Based Design and Optimization of Blood Oxygenators. Journal of Medical Devices, 14(4).
https://doi.org/10.1115/1.4047872
-
Whitaker, S. (1986). Flow in porous media I: A theoretical derivation of Darcy's law. Transport in Porous Media, 1(1), 3–25.
https://doi.org/10.1007/bf01036523
-
Rai, R., & Sahu, C. K. (2020). Driven by Data or Derived Through Physics? A Review of Hybrid Physics Guided Machine Learning Techniques With Cyber-Physical System (CPS) Focus. IEEE Access, 8, 71050–71073.
https://doi.org/10.1109/access.2020.2987324
-
Asbai-Ghoudan, R., Ruiz de Galarreta, S., & Rodriguez-Florez, N. (2021). Analytical model for the prediction of permeability of triply periodic minimal surfaces. Journal of the Mechanical Behavior of Biomedical Materials, 124, 104804.
https://doi.org/10.1016/j.jmbbm.2021.104804
-
Ali, D., Ozalp, M., Blanquer, S. B. G., & Onel, S. (2020). Permeability and fluid flow-induced wall shear stress in bone scaffolds with TPMS and lattice architectures: A CFD analysis. European Journal of Mechanics - B/Fluids, 79, 376–385.
https://doi.org/10.1016/j.euromechflu.2019.09.015
- Study on the scale characteristics of permeability of TPMS porous materials
-
Rathore, S. S., Mehta, B., Kumar, P., & Asfer, M. (2022). Flow Characterization in Triply Periodic Minimal Surface (TPMS)-Based Porous Geometries: Part 1—Hydrodynamics. Transport in Porous Media, 146(3), 669–701.
https://doi.org/10.1007/s11242-022-01880-7
-
Jones, C. C., McDonough, J. M., Capasso, P., Wang, D., Rosenstein, K. S., & Zwischenberger, J. B. (2013). Improved Computational Fluid Dynamic Simulations of Blood Flow in Membrane Oxygenators from X-ray Imaging. Annals of Biomedical Engineering, 41(10), 2088–2098.
https://doi.org/10.1007/s10439-013-0824-4
-
Lenci, A., Zeighami, F., & Di Federico, V. (2022). Effective Forchheimer Coefficient for Layered Porous Media. Transport in Porous Media, 144(2), 459–480.
https://doi.org/10.1007/s11242-022-01815-2
-
Li, D., & Engler, T. W. (2001, May 15). Literature Review on Correlations of the Non-Darcy Coefficient. SPE Permian Basin Oil and Gas Recovery Conference.
https://doi.org/10.2118/70015-ms
-
Pascal, H., & Quillian, R. (1980, September). ANALYSIS OF VERTICAL FRACTURE LENGTH AND NON-DARCY FLOW COEFFICIENT USING VARIABLE RATE TESTS. Proceedings of SPE Annual Technical Conference and Exhibition.
https://doi.org/10.2523/9348-ms
- The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves
-
Svitek, R. G., & Federspiel, W. J. (2008). A Mathematical Model to Predict CO2 Removal in Hollow Fiber Membrane Oxygenators. Annals of Biomedical Engineering, 36(6), 992–1003.
https://doi.org/10.1007/s10439-008-9482-3
-
Zhou, X., Loran, D. B., Wang, D., Hyde, B. R., Lick, S. D., & Zwischenberger, J. B. (2005). Seventy-two hour gas exchange performance and hemodynamic properties of NOVALUNG®iLA as a gas exchanger for arteriovenous carbon dioxide removal. Perfusion, 20(6), 303–308.
https://doi.org/10.1191/0267659105pf838oa
-
Sonntag, S. J., Kaufmann, T. A. S., Büsen, M. R., Laumen, M., Gräf, F., Linde, T., & Steinseifer, U. (2014). Numerical Washout Study of a Pulsatile Total Artificial Heart. The International Journal of Artificial Organs, 37(3), 241–252.
https://doi.org/10.5301/ijao.5000306
-
Despotovic, M., Nedic, V., Despotovic, D., & Cvetanovic, S. (2016). Evaluation of empirical models for predicting monthly mean horizontal diffuse solar radiation. Renewable and Sustainable Energy Reviews, 56, 246–260.
https://doi.org/10.1016/j.rser.2015.11.058
-
Göçken, M., Özçalıcı, M., Boru, A., & Dosdoğru, A. T. (2016). Integrating metaheuristics and Artificial Neural Networks for improved stock price prediction. Expert Systems with Applications, 44, 320–331.
https://doi.org/10.1016/j.eswa.2015.09.029
-
Partopour, B., & Dixon, A. G. (2019). 110th Anniversary: Commentary: CFD as a Modeling Tool for Fixed Bed Reactors. Industrial & Engineering Chemistry Research, 58(14), 5733–5736.
https://doi.org/10.1021/acs.iecr.8b06380
-
Prasianakis, N. I., Haller, R., Mahrous, M., Poonoosamy, J., Pfingsten, W., & Churakov, S. V. (2020). Neural network based process coupling and parameter upscaling in reactive transport simulations. Geochimica Et Cosmochimica Acta, 291, 126–143.
https://doi.org/10.1016/j.gca.2020.07.019
-
Rabbani, A., & Babaei, M. (2019). Hybrid pore-network and lattice-Boltzmann permeability modelling accelerated by machine learning. Advances in Water Resources, 126, 116–128.
https://doi.org/10.1016/j.advwatres.2019.02.012
-
Marcato, A., Boccardo, G., & Marchisio, D. (2022). From Computational Fluid Dynamics to Structure Interpretation via Neural Networks: An Application to Flow and Transport in Porous Media. Industrial & Engineering Chemistry Research, 61(24), 8530–8541.
https://doi.org/10.1021/acs.iecr.1c04760
-
Blum, C., Groß-Hardt, S., Steinseifer, U., & Neidlin, M. (2022). An Accelerated Thrombosis Model for Computational Fluid Dynamics Simulations in Rotary Blood Pumps. Cardiovascular Engineering and Technology, 13(4), 638–649.
https://doi.org/10.1007/s13239-021-00606-y
-
Méndez Rojano, R., Lai, A., Zhussupbekov, M., Burgreen, G. W., Cook, K., Antaki, J. F., & Marsden, A. L. (2022). A fibrin enhanced thrombosis model for medical devices operating at low shear regimes or large surface areas. PLOS Computational Biology, 18(10), e1010277.
https://doi.org/10.1371/journal.pcbi.1010277
-
Fang, P., Du, J., Boraschi, A., Bozzi, S., Redaelli, A., Schmid Daners, M., Kurtcuoglu, V., Consolo, F., & de Zélicourt, D. (2022). Insights Into the Low Rate of In-Pump Thrombosis With the HeartMate 3: Does the Artificial Pulse Improve Washout?. Frontiers in Cardiovascular Medicine, 9.
https://doi.org/10.3389/fcvm.2022.775780
-
Pflaum, M., Barbian, K. P., Neuhaus, F., Sitarz, G., Nölke, C., Jansen, S. V., Linkhorst, J., Hirschwald, L. T., Brosch, S., Certa, C., Steinseifer, U., Wessling, M., Arens, J., Ruhparwar, A., & Wiegmann, B. (2026). From Fiber Bundles to Architected Membranes: Triply Periodic Minimal Surface Architectures for Biohybrid Artificial Lungs. Advanced Materials, 38(55).
https://doi.org/10.1002/adma.74361
-
Ameri, A., Duwig, C., & Kusar, H. (2026). Liquid distribution performance of Triply Periodic Minimal Surface packings: Effects of topology, porosity, flow rate and inlet configuration. Chemical Engineering Research and Design, 229, 237–252.
https://doi.org/10.1016/j.cherd.2026.04.002
-
Barbian, K. P., Lemainque, T., Grunden, I., Iwa, R., Wiegmann, B., Linkhorst, J., Wessling, M., Heyer, J., Steinseifer, U., Neidlin, M., & Jansen, S. V. (2025). Tailored 3D Lattice Microstructures for Enhanced Functionality in Blood‐Gas Exchange. Advanced Science, 12(25).
https://doi.org/10.1002/advs.202501162
-
Barbian, K. P., Neuhaus, F., Hirschwald, L. T., Linkhorst, J., Wessling, M., Wiegmann, B., Focke, J. M., Steinseifer, U., Neidlin, M., & Jansen, S. V. (2025). 3D Membrane Microstructures for Increased Efficiency in Blood‐Gas Transfer. Advanced Science, 12(47).
https://doi.org/10.1002/advs.202512302
-
Kılıç, M. A., Akyürek, M., Abidnejad, R., & Karakoç, A. (2025). Evaluation of triply periodic minimal surface geometries in 3D ‐printed PLA scaffolds for chondrogenic differentiation. Biotechnology Progress, 41(6).
https://doi.org/10.1002/btpr.70062
-
Gregory, S. D., Stephens, A. F., Heinsar, S., Arens, J., & Fraser, J. F. (2025). The past, present, and future of mechanical circulatory and respiratory support. In Mechanical Circulatory and Respiratory Support (pp. 883–899). Elsevier.
https://doi.org/10.1016/b978-0-443-22148-4.00037-x
-
Gupta, A., Rana, M., & Mondal, N. (2025). Determining the optimal design parameters for gyroids using computational fluid dynamics analysis under a non-Newtonian perfusion system. Biomedical Engineering Advances, 9, 100153.
https://doi.org/10.1016/j.bea.2025.100153
-
Ullah, A., Gölcez, T., Teber, O. O., Koyuncu, İ., Kerem Uğuz, A., & Pekkan, K. (2025). A microfluidic technique for measuring fiber-level mass transport efficiency and hemolysis of blood oxygenators. Biomicrofluidics, 19(6).
https://doi.org/10.1063/5.0293504
-
Li, W. (2025). Numerical Investigation of Gas Exchange Processes in Hollow-Fiber Membrane Bundles. ASAIO Journal, 72(1), 32–41.
https://doi.org/10.1097/mat.0000000000002444
-
Askew, K., Rizzo, J., Fan, L., & He, G. (2025). Computational Fluid Dynamics Modeling of Sweep Gas Flow Rate-Dependent Carbon Dioxide Removal in Oxygenators. Fluids, 10(6), 158.
https://doi.org/10.3390/fluids10060158
-
Gluns, J., Zhao, L., Spiehl, D., Mikolei, J. J., Pardehkhorram, R., Ceolin, M., & Andrieu‐Brunsen, A. (2024). 3D Printing of Ordered Mesoporous Silica Using Light‐Induced Sol‐Gel Chemistry. Advanced Functional Materials, 34(46).
https://doi.org/10.1002/adfm.202405511
-
Hirschwald, L. T., Hagemann, F., Biermann, M., Hanßen, P., Hoffmann, P., Höhs, T., Neuhaus, F., Tillmann, M. T., Peric, P., Wattenberg, M., Stille, M., Fechter, T., Theißen, A., Winnersbach, P., Barbian, K. P., Jansen, S. V., Steinseifer, U., Wiegmann, B., Rossaint, R., … Linkhorst, J. (2024). Enhanced Hemodynamics of Anisometric TPMS Topology Reduce Blood Clotting in 3D Printed Blood Contactors. Advanced Healthcare Materials, 14(2).
https://doi.org/10.1002/adhm.202403111
-
Poletti, G., Bardón, R. G., Dubini, G., & Pennati, G. (2024). CFD Two-Phase Blood Model Predicting the Hematocrit Heterogeneity Inside Fiber Bundles of Blood Oxygenators. Annals of Biomedical Engineering, 53(2), 507–519.
https://doi.org/10.1007/s10439-024-03644-4
-
Li, J., Luo, K., Qi, W., Du, J., Huang, Y., & Lu, C. (2024). Prediction of the mechanical properties of TPMS structures based on Back propagation neural network. Computer Methods in Biomechanics and Biomedical Engineering, 28(7), 949–961.
https://doi.org/10.1080/10255842.2024.2307917