Comparison of phase-resolved functional lung (PREFUL) MRI derived perfusion and ventilation parameters at 1.5T and 3T in healthy volunteers
Authors/Creators
Contributors
Editor:
Description
Purpose The purpose of this study is to evaluate the influence of different field strengths on perfusion and ventilation parameters, SNR and CNR derived by PREFUL MRI using predefined sequence parameters. Methods Data sets of free breathing 2d FLASH lung MRI were acquired from 15 healthy subjects at 1.5T and 3T (Magnetom Avanto and Skyra, Siemens Healthcare, Erlangen, Germany) with a maximum period of 3 days in between. The processed functional parameters regional ventilation (RVent), perfusion (Q), quantified perfusion (QQuant), perfusion defect percentage (QDP), ventilation defect percentage (VDP) and ventilation-perfusion match (VQM) were compared for systematic differences. Signal- and contrast-to-noise ratio (SNR and CNR) of both acquisitions were analyzed. Results RVent, Q, VDP, SNR and CNR presented no significant differences between 1.5T and 3T. QQuant (1.5T vs. 3T, P = 0.04), and QDP (1.5T vs. 3T, P≤0.01) decreased significantly at 3T. Consequently, VQM increased significantly (1.5T vs. 3T, P≤0.01). Skewness and kurtosis of the Q-values increased significantly at 3T (P≤0.01). The mean Sørensen-Dice coefficients between both series were 0.91 for QDP and 0.94 for VDP. The Bland-Altman analysis of both series showed mean differences of 4.29% for QDP, 1.23% for VDP and -5.15% for VQM. Using the above-mentioned parameters for three-day repeatability at two different scanners and field strengths, the retrospective power calculation showed, that a sample size of 15 can detect differences of 3.7% for QDP, of 2.9% for VDP and differences of 2.6% for VQM. Conclusion Significant differences in QDP may be related to field inhomogeneities, which is expressed by increasing skewness and kurtosis at 3T. QQuant reveals only poor reproducibility between 1.5T and 3T. RVent, Q, VDP, SNR and CNR were not altered significantly at the used sequence parameters. Healthy participants with minimal defects present high spatial agreement of QDP and VDP.
Additional details
Identifiers
- OpenAlex
- W3118186393
- PMID
- 33378373
- URL
- https://dx.plos.org/10.1371/journal.pone.0244638
Funding
-
British Heart Foundation
- POLARIS: Pulmonary, Lung and Respiratory Imaging Sheffield (Joint funding with MRC) SP/14/6/31350
-
Medical Research Council
- MR/M008894/1
-
National Institute for Health and Care Research
- Translating novel pulmonary MR imaging methods in to clinical practice NIHR-RP-R3-12-027
-
Cystic Fibrosis Foundation
-
German Center for Lung Research
Dates
- Issued
-
December 30, 2020
References
- Forum of International Respiratory Societies. The Global Impact of Respiratory Disease—Second Edition. Sheffield; 2017.
- World Health Organization. World health statistics 2008. Geneva; 2008.
- Ebert, M., Grossmann, T., Heil, W., Otten, E. W., Surkau, R., Thelen, M., Leduc, M., Bachert, P., Knopp, M. V., & Schad, L. R. (1996). Nuclear magnetic resonance imaging with hyperpolarised helium-3. The Lancet, 347(9011), 1297–1299. https://doi.org/10.1016/s0140-6736(96)90940-x
- Kauczor, H.-U. (2003). Hyperpolarized Helium-3 Gas Magnetic Resonance Imaging of the Lung. Topics in Magnetic Resonance Imaging, 14(3), 223–230. https://doi.org/10.1097/00002142-200306000-00002
- Couch, M. J., Ball, I. K., Li, T., Fox, M. S., Biman, B., & Albert, M. S. (2018). 19F MRI of the Lungs Using Inert Fluorinated Gases: Challenges and New Developments. Journal of Magnetic Resonance Imaging, 49(2), 343–354. https://doi.org/10.1002/jmri.26292
- Hopkins, S. R., Wielpütz, M. O., & Kauczor, H.-U. (2012). Imaging lung perfusion. Journal of Applied Physiology, 113(2), 328–339. https://doi.org/10.1152/japplphysiol.00320.2012
- Cha, M. J., Kang, D. Y., Lee, W., Yoon, S. H., Choi, Y. H., Byun, J. S., Lee, J., Kim, Y.-H., Choo, K. S., Cho, B. S., Jeon, K. N., Jung, J.-W., & Kang, H.-R. (2019). Hypersensitivity Reactions to Iodinated Contrast Media: A Multicenter Study of 196 081 Patients. Radiology, 293(1), 117–124. https://doi.org/10.1148/radiol.2019190485
- Grobner, T. (2006). Gadolinium – a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?. Nephrology Dialysis Transplantation, 21(4), 1104–1108. https://doi.org/10.1093/ndt/gfk062
- Enright, P. L., Beck, K. C., & Sherrill, D. L. (2004). Repeatability of Spirometry in 18,000 Adult Patients. American Journal of Respiratory and Critical Care Medicine, 169(2), 235–238. https://doi.org/10.1164/rccm.200204-347oc
- Zapke, M., Topf, H.-G., Zenker, M., Kuth, R., Deimling, M., Kreisler, P., Rauh, M., Chefd'hotel, C., Geiger, B., & Rupprecht, T. (2006). Magnetic resonance lung function – a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial. Respiratory Research, 7(1). https://doi.org/10.1186/1465-9921-7-106
- Bankier, A. A., O'Donnell, C. R., Mai, V. M., Storey, P., De Maertelaer, V., Edelman, R. R., & Chen, Q. (2004). Impact of lung volume on MR signal intensity changes of the lung parenchyma. Journal of Magnetic Resonance Imaging, 20(6), 961–966. https://doi.org/10.1002/jmri.20198
- Voskrebenzev, A., Gutberlet, M., Klimeš, F., Kaireit, T. F., Schönfeld, C., Rotärmel, A., Wacker, F., & Vogel‐Claussen, J. (2017). Feasibility of quantitative regional ventilation and perfusion mapping with phase‐resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magnetic Resonance in Medicine, 79(4), 2306–2314. https://doi.org/10.1002/mrm.26893
- Kaireit, T. F., Gutberlet, M., Voskrebenzev, A., Freise, J., Welte, T., Hohlfeld, J. M., Wacker, F., & Vogel‐Claussen, J. (2017). Comparison of quantitative regional ventilation‐weighted fourier decomposition MRI with dynamic fluorinated gas washout MRI and lung function testing in COPD patients. Journal of Magnetic Resonance Imaging, 47(6), 1534–1541. https://doi.org/10.1002/jmri.25902
- Voskrebenzev, A., Greer, M., Gutberlet, M., Schönfeld, C., Renne, J., Hinrichs, J., Kaireit, T., Welte, T., Wacker, F., Gottlieb, J., & Vogel-Claussen, J. (2018). Detection of chronic lung allograft dysfunction using ventilation-weighted Fourier decomposition MRI. American Journal of Transplantation, 18(8), 2050–2060. https://doi.org/10.1111/ajt.14759
- Schoenfeld, C., Cebotari, S., Hinrichs, J., Renne, J., Kaireit, T., Olsson, K. M., Voskrebenzev, A., Gutberlet, M., Hoeper, M. M., Welte, T., Haverich, A., Wacker, F., & Vogel-Claussen, J. (2016). MR Imaging–derived Regional Pulmonary Parenchymal Perfusion and Cardiac Function for Monitoring Patients with Chronic Thromboembolic Pulmonary Hypertension before and after Pulmonary Endarterectomy. Radiology, 279(3), 925–934. https://doi.org/10.1148/radiol.2015150765
- Veldhoen, S., Weng, A. M., Knapp, J., Kunz, A. S., Stäb, D., Wirth, C., Segerer, F., Hebestreit, H., Malzahn, U., Köstler, H., & Bley, T. A. (2017). Self-gated Non–Contrast-enhanced Functional Lung MR Imaging for Quantitative Ventilation Assessment in Patients with Cystic Fibrosis. Radiology, 283(1), 242–251. https://doi.org/10.1148/radiol.2016160355
- Vogel-Claussen, J., Schönfeld, C.-O., Kaireit, T. F., Voskrebenzev, A., Czerner, C. P., Renne, J., Tillmann, H.-C., Berschneider, K., Hiltl, S., Bauersachs, J., Welte, T., & Hohlfeld, J. M. (2019). Effect of Indacaterol/Glycopyrronium on Pulmonary Perfusion and Ventilation in Hyperinflated Patients with Chronic Obstructive Pulmonary Disease (CLAIM). A Double-Blind, Randomized, Crossover Trial. American Journal of Respiratory and Critical Care Medicine, 199(9), 1086–1096. https://doi.org/10.1164/rccm.201805-0995oc
- Klimeš, F., Voskrebenzev, A., Gutberlet, M., Kern, A., Behrendt, L., Kaireit, T. F., Czerner, C., Renne, J., Wacker, F., & Vogel‐Claussen, J. (2019). Free‐breathing quantification of regional ventilation derived by phase‐resolved functional lung (PREFUL) MRI. NMR in Biomedicine, 32(6), Article e4088. https://doi.org/10.1002/nbm.4088
- Effect of intravenously injected gadolinium-based contrast agents on functional lung parameters derived by PREFUL MRI
- Soher, B. J., Dale, B. M., & Merkle, E. M. (2007). A Review of MR Physics: 3T versus 1.5T. Magnetic Resonance Imaging Clinics of North America, 15(3), 277–290. https://doi.org/10.1016/j.mric.2007.06.002
- Barth, M. M., Smith, M. P., Pedrosa, I., Lenkinski, R. E., & Rofsky, N. M. (2007). Body MR Imaging at 3.0 T: Understanding the Opportunities and Challenges. RadioGraphics, 27(5), 1445–1462. https://doi.org/10.1148/rg.275065204
- Kauczor, H.-U., & Kreitner, K.-F. (2000). Contrast-enhanced MRI of the lung. European Journal of Radiology, 34(3), 196–207. https://doi.org/10.1016/s0720-048x(00)00199-6
- Mulkern, R., Haker, S., Mamata, H., Lee, E., Mitsouras, D., Oshio, K., Balasubramanian, M., & Hatabu, H. (2014). Lung parenchymal signal intensity in MRI: A technical review with educational aspirations regarding reversible versus irreversible transverse relaxation effects in common pulse sequences. Concepts in Magnetic Resonance Part A, 43A(2), 29–53. https://doi.org/10.1002/cmr.a.21297
- Bauman, G., Pusterla, O., & Bieri, O. (2018). Functional lung imaging with transient spoiled gradient echo. Magnetic Resonance in Medicine, 81(3), 1915–1923. https://doi.org/10.1002/mrm.27535
- Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011). A reproducible evaluation of ANTs similarity metric performance in brain image registration. NeuroImage, 54(3), 2033–2044. https://doi.org/10.1016/j.neuroimage.2010.09.025
1–25 of 47
Citations
- Kroschke, J., Huber, Y., Kerber, B., Lohezic, M., & Frauenfelder, T. (2026). Impact of a deep-learning image reconstruction algorithm on ventilation and perfusion parameters derived by phase-resolved functional lung (PREFUL) magnetic resonance imaging (MRI) in a prospective healthy cohort. Clinical Radiology, 94, 107248. https://doi.org/10.1016/j.crad.2026.107248
- Tan, L., Wagner, A. L., Heiss, R., Bayerl, N., Zschüntzsch, J., Regensburger, A. P., Alves, F., Türk, M., Schmidt, S., Grimm, R., Vorgerd, M., Schlaffke, L., Vogt-Wolz, H., Claßen, M., Stoecklein, B., Buehler, A., Woelfle, J., Uder, M., Hahn, A., … Knieling, F. (2026). Mapping lung function in late-onset Pompe disease using label-free functional MRI. iScience, 29(3), 115136. https://doi.org/10.1016/j.isci.2026.115136
- Yamamoto, S., & Sakamaki, F. (2026). Current perspectives on imaging modalities in the diagnosis and management of pulmonary hypertension. Respiratory Investigation, 64(2), 101389. https://doi.org/10.1016/j.resinv.2026.101389
- https://doi.org/10.1038/s43856-025-01365-w
- https://doi.org/10.1186/s12880-026-02519-5
- https://doi.org/10.1186/s12890-026-04562-y
- https://doi.org/10.1093/bjr/tqaf249
- https://doi.org/10.1186/s12931-025-03372-w
- https://doi.org/10.14814/phy2.70423
- https://doi.org/10.3389/fphy.2025.1611544
- Peggs, Z. J. T., Brooke, J. P., Bolton, C. E., Hall, I. P., Francis, S. T., & Gowland, P. A. (2024). Free‐Breathing Functional Pulmonary Proton MRI: A Novel Approach Using Voxel‐Wise Lung Ventilation (VOLVE) Assessment in Healthy Volunteers and Patients With Chronic Obstructive Pulmonary Disease. Journal of Magnetic Resonance Imaging, 61(2), 663–675. https://doi.org/10.1002/jmri.29444
- Moher Alsady, T., Ruschepaul, J., Voskrebenzev, A., Klimes, F., Poehler, G. H., & Vogel‐Claussen, J. (2024). Estimating ventilation correlation coefficients in the lungs using PREFUL‐MRI in chronic obstructive pulmonary disease patients and healthy adults. Magnetic Resonance in Medicine, 91(5), 2142–2152. https://doi.org/10.1002/mrm.29982
- Behrendt, L., Gutberlet, M., Voskrebenzev, A., Klimeš, F., Obert, A. J., Kern, A. L., Horstmann, D., Wernz, M. M., Müller, R. A., Wacker, F., & Vogel‐Claussen, J. (2024). Influence of echo time on pulmonary ventilation and perfusion derived by phase‐resolved functional lung (PREFUL) MRI using multi‐echo ultrashort echo time acquisition. NMR in Biomedicine, 37(12), Article e5270. https://doi.org/10.1002/nbm.5270
- Taran, T. V., Pavlova, O. S., Gulyaev, M. V., Dmitriev, D. S., Pistrak, A. G., Ryabikov, K. N., Tarasov, V. P., & Pirogov, Y. A. (2024). Automated Image Registration and Perfusion Sorting Algorithms for PREFUL MRI. Applied Magnetic Resonance, 55(8), 741–752. https://doi.org/10.1007/s00723-024-01684-6
- https://doi.org/10.3389/fonc.2024.1429837
- https://doi.org/10.3791/66380
- https://doi.org/10.1148/radiol.221250
- https://doi.org/10.1148/radiol.221958
- https://doi.org/10.1371/journal.pone.0288744
- https://doi.org/10.3389/fmed.2023.1060940
- https://doi.org/10.3389/fmed.2023.1256925
- Ilicak, E., Ozdemir, S., Schad, L. R., Weis, M., Schoenberg, S. O., Zöllner, F. G., & Zapp, J. (2022). Phase‐cycled balanced SSFP imaging for non‐contrast‐enhanced functional lung imaging. Magnetic Resonance in Medicine, 88(4), 1764–1774. https://doi.org/10.1002/mrm.29302
- Behrendt, L., Smith, L. J., Voskrebenzev, A., Klimeš, F., Kaireit, T. F., Pöhler, G. H., Kern, A. L., Gonzalez, C. C., Dittrich, A., Marshall, H., Schütz, K., Hughes, P. J. C., Ciet, P., Tiddens, H. A. W. M., Wild, J. M., & Vogel‐Claussen, J. (2022). A dual center and dual vendor comparison study of automated perfusion‐weighted phase‐resolved functional lung magnetic resonance imaging with dynamic contrast‐enhanced magnetic resonance imaging in patients with cystic fibrosis. Pulmonary Circulation, 12(2), Article e12054. https://doi.org/10.1002/pul2.12054
- Gräfe, D., Prenzel, F., & Hirsch, F. W. (2022). Chest magnetic resonance imaging in cystic fibrosis: technique and clinical benefits. Pediatric Radiology, 53(4), 640–648. https://doi.org/10.1007/s00247-022-05539-9
- https://doi.org/10.1097/rli.0000000000000892
1–25 of 26