Published June 2020 | Journal article | Version v1 | https://doi.org/10.1093/raddos/ncaa070

COMPARISON OF EXPERIMENTAL AND NUMERICAL METHODS OF PATIENT DOSE ESTIMATIONS IN CT USING ANTHROPOMORPHIC MODELS

  • 1. Institute of Radiation Medicine, Helmholtz Zentrum München–German Research Center for Environmental Health, 85764 Neuherberg, Germany
  • 2. Lehrstuhl für Experimentelle Physik IV, Technische Universität Dortmund, 44227 Dortmund, Germany
  • 3. Medizinischer und beruflicher Strahlenschutz, Bundesamt für Strahlenschutz, 85764 Neuherberg, Germany
  • 4. Hirslanden AG, 8152 Glattpark, Switzerland
  • 5. ROR icon Medizinische Hochschule Hannover
  • 6. ROR icon Helmholtz Munich

Description

AbstractThe common methods for patient dose estimations in computed tomography (CT) are thermoluminescence dosemeter (TLD) measurements or the usage of software packages based on Monte Carlo simulations like CT-Expo or the newer CTVoxDos, which uses the ICRP Reference Adult Male (ICRP 110). Organ (OD) and effective doses of a CT protocol of the upper abdomen are compared. Compared to CTVoxDos, ODs inferred by TLD measurement using an anthropomorphic phantom differ by $\mathbf{(19\pm 16)\,\%}$ inside the primary radiation field, $\mathbf{(14\pm 2)\,\%}$ for partially primary irradiated organs and $\mathbf{(34\pm 38)\,\%}$ in the scattered radiation field. ODs estimated by CT-Expo show a mean deviation of $\mathbf{(16\pm 9)\,\%}$ (primary irradiated) and $\mathbf{(28\pm 31)\,\%}$ (scatter irradiated) from ODs estimated by CTVoxDos.

Additional details

Dates

Issued
June 2020

References

  1. Umweltradioaktivität und Strahlenbelastung
  2. ORNL-4168. Oak Ridge National Laboratory
  3. Zankl, M., Veit, R., Williams, G., Schneider, K., Fendel, H., Petoussi, N., & Drexler, G. (1988). The construction of computer tomographic phantoms and their application in radiology and radiation protection. Radiation and Environmental Biophysics, 27(2), 153–164. https://doi.org/10.1007/bf01214605
  4. Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994). Computerized three‐dimensional segmented human anatomy. Medical Physics, 21(2), 299–302. https://doi.org/10.1118/1.597290
  5. VIP-MAN: an image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations
  6. Zankl, M., & Wittmann, A. (2001). The adult male voxel model ”Golem" segmented from whole-body CT patient data. Radiation and Environmental Biophysics, 40(2), 153–162. https://doi.org/10.1007/s004110100094
  7. Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2001). The GSF family of voxel phantoms. Physics in Medicine and Biology, 47(1), 89–106. https://doi.org/10.1088/0031-9155/47/1/307
  8. Basic Anatomical and Physiological Data for use in Radiological Protection
  9. Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D. (2002). Organ dose conversion coefficients for external photon irradiation of male and female voxel models. Physics in Medicine and Biology, 47(14), 2367–2385. https://doi.org/10.1088/0031-9155/47/14/301
  10. Kramer, R., Vieira, J. W., Khoury, H. J., & Lima, F. de A. (2004). MAX meets ADAM: a dosimetric comparison between a voxel-based and a mathematical model for external exposure to photons. Physics in Medicine and Biology, 49(6), 887–910. https://doi.org/10.1088/0031-9155/49/6/002
  11. Liu, H., Gu, J., Caracappa, P. F., & Xu, X. G. (2010). Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures. Physics in Medicine and Biology, 55(5), 1441–1451. https://doi.org/10.1088/0031-9155/55/5/012
  12. Lee, C., Kim, K. P., Long, D., Fisher, R., Tien, C., Simon, S. L., Bouville, A., & Bolch, W. E. (2011). Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations. Medical Physics, 38(3), 1196–1206. https://doi.org/10.1118/1.3544658
  13. Zhang, Y., Li, X., Paul Segars, W., & Samei, E. (2012). Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols. Medical Physics, 39(6Part1), 3404–3423. https://doi.org/10.1118/1.4718710
  14. Kalender, W. A., Schmidt, B., Zankl, M., & Schmidt, M. (1999). A PC program for estimating organ dose and effective dose values in computed tomography. European Radiology, 9(3), 555–562. https://doi.org/10.1007/s003300050709
  15. Stamm, G., & Nagel, H. D. (2002). CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 174(12), 1570–1576. https://doi.org/10.1055/s-2002-35937
  16. CT patient dosimetry calculator Excel spreadsheet
  17. Annals ICRP
  18. Schlattl, H., Zankl, M., Becker, J., & Hoeschen, C. (2010). Dose conversion coefficients for CT examinations of adults with automatic tube current modulation. Physics in Medicine and Biology, 55(20), 6243–6261. https://doi.org/10.1088/0031-9155/55/20/013
  19. Schlattl, H., Zankl, M., Becker, J., & Hoeschen, C. (2012). Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation. Physics in Medicine and Biology, 57(20), 6309–6326. https://doi.org/10.1088/0031-9155/57/20/6309
  20. NRCC Report PIRS-701
  21. Turner, A. C., Zankl, M., DeMarco, J. J., Cagnon, C. H., Zhang, D., Angel, E., Cody, D. D., Stevens, D. M., McCollough, C. H., & McNitt-Gray, M. F. (2010). The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners. Medical Physics, 37(4), 1816–1825. https://doi.org/10.1118/1.3368596
  22. ICRP Publication 103
  23. Lechel, U., Becker, C., Langenfeld-Jäger, G., & Brix, G. (2008). Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation. European Radiology, 19(4), 1027–1034. https://doi.org/10.1007/s00330-008-1204-6
  24. SLAC National Accelerator Laboratory (SLAC), M. P. C. (United S., Nelson, W., (SC), U. O. of S., Hirayama, H., & Rogers, D. (1985). The EGS4 Code System. In SLAC National Accelerator Laboratory (SLAC), Menlo Park, CA (United States). Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/1453993
  25. Turner, A. C., Zhang, D., Kim, H. J., DeMarco, J. J., Cagnon, C. H., Angel, E., Cody, D. D., Stevens, D. M., Primak, A. N., McCollough, C. H., & McNitt‐Gray, M. F. (2009). A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. Medical Physics, 36(6Part1), 2154–2164. https://doi.org/10.1118/1.3117683

1–25 of 28