Published October 2007 | Journal article | Version v1 | https://doi.org/10.1177/039139880703001002

Prometheus: From Legend to the Real Liver Support Therapy

Description

Background A large number of patients develop liver disease that may evolve into progressive chronic failure. Artificial liver support systems (e.g., MARS and Prometheus) are considered in the framework of the steady increase in the number of patients who could possibly benefit from these blood purification devices. Albumin dialysis and adsorption are now two integrated concepts. The present know-how enabling us to appropriately modify several intrinsic characteristics of the adsorbents - e.g., their chemical nature, the particle and pore size distribution, as well as a larger surface offered to adsorption - has helped in better fine-tuning liver support systems to improve adsorption kinetics and flow characteristics specifically for the intended clinical application. These properties together with an improved biocompatibility have made possible the development of adsorptive techniques for which clearances and total removal rates of target compound would be unthinkable with conventional hemodialysis or hemofiltration. Several adsorptive techniques are already available commercially for the treatment of sepsis and septic shock and of acute liver failure, but controlled studies with clinical end points are still lacking.

Additional details

Dates

Issued
October 2007

References

  1. La Greca, G., Brendolan, A., Ghezzi, P. M., De Smet, R., Tetta, C., Gervasio, R., & Ronco, C. (1998). The Concept of Sorbent in Hemodialysis. The International Journal of Artificial Organs, 21(6), 303–308. https://doi.org/10.1177/039139889802100604
  2. De Nitti, C., Giordano, R., Gervasio, R., Castellano, G., Podio, V., Sereni, L., Ghezzi, P. M., Ronco, C., Brendolan, A., Inguaggiato, P., Tonelli, M., La Greca, G., & Tetta, C. (2001). Choosing New Adsorbents for Endogenous Ultrapure Infusion Fluid: Performances, Safety and Flow Distribution. The International Journal of Artificial Organs, 24(11), 765–776. https://doi.org/10.1177/039139880102401102
  3. Winchester, J. F., Silberzweig, J., Ronco, C., Kuntsevich, V., Levine, D., Parker, T., Kellum, J. A., Salsberg, J. A., Quartararo, P., & Levin, N. W. (2004). Sorbents in Acute Renal Failure and End-Stage Renal Disease: Middle Molecule and Cytokine Removal. Blood Purification, 22(1), 73–77. https://doi.org/10.1159/000074926
  4. Tetta, C., Bellomo, R., Brendolan, A., Piccinni, P., Digito, A., Dan, M., Irone, M., Lonnemann, G., Moscato, D., Buades, J., La Greca, G., & Ronco, C. (1999). Use of adsorptive mechanisms in continuous renal replacement therapies in the critically ill. Kidney International, 56, S15–S19. https://doi.org/10.1046/j.1523-1755.56.s72.16.x
  5. Kellum, J. A., Song, M., & Venkataraman, R. (2004). Hemoadsorption removes tumor necrosis factor, interleukin-6, and interleukin-10, reduces nuclear factor-κB DNA binding, and improves short-term survival in lethal endotoxemia*. Critical Care Medicine, 32(3), 801–805. https://doi.org/10.1097/01.ccm.0000114997.39857.69
  6. Stange, J., Hassanein, T. I., Mehta, R., Mitzner, S. R., & Bartlett, R. H. (2002). The Molecular Adsorbents Recycling System as a Liver Support System Based on Albumin Dialysis: A Summary of Preclinical Investigations, Prospective, Randomized, Controlled Clinical Trial, and Clinical Experience from 19 Centers. Artificial Organs, 26(2), 103–110. https://doi.org/10.1046/j.1525-1594.2002.06822.x
  7. Strobl, W., Vogt, G., Mitteregger, R., Schönhofen, M., Gerner, F. J., & Falkenhagen, D. (1998). Das "Fractionated Plasma Separation and Adsorption System" (FPSA), ein neues membran- adsorptionsgestütztes adjunktives extrakorporales Blutreinigungssystem für das Leberversagen. Biomedizinische Technik/Biomedical Engineering, 43(s1), 168–169. https://doi.org/10.1515/bmte.1998.43.s1.168
  8. Falkenhagen, D., Strobl, W., Vogt, G., Schrefl, A., Linsberger, I., Gerner, F. J., & Schoenhofen, M. (1999). Fractionated Plasma Separation and Adsorption System: A Novel System for Blood Purification to Remove Albumin Bound Substances. Artificial Organs, 23(1), 81–86. https://doi.org/10.1046/j.1525-1594.1999.06292.x
  9. Krisper, P., & Stauber, R. E. (2007). Technology Insight: artificial extracorporeal liver support—how does Prometheus® compare with MARS®?. Nature Clinical Practice Nephrology, 3(5), 267–276. https://doi.org/10.1038/ncpneph0466
  10. Evenepoel, P., Laleman, W., Wilmer, A., Claes, K., Kuypers, D., Bammens, B., Nevens, F., & Vanrenterghem, Y. (2006). Prometheus Versus Molecular Adsorbents Recirculating System: Comparison of Efficiency in Two Different Liver Detoxification Devices. Artificial Organs, 30(4), 276–284. https://doi.org/10.1111/j.1525-1594.2006.00215.x
  11. Jalan, R., & Williams, R. (2002). Acute-on-Chronic Liver Failure: Pathophysiological Basis of Therapeutic Options. Blood Purification, 20(3), 252–261. https://doi.org/10.1159/000047017
  12. Evenepoel, P., Laleman, W., Wilmer, A., Claes, K., Maes, B., Kuypers, D., Bammens, B., Nevens, F., & Vanrenterghem, Y. (2005). Detoxifying Capacity and Kinetics of Prometheus<sup>®</sup> – A New Extracorporeal System for the Treatment of Liver Failure. Blood Purification, 23(5), 349–358. https://doi.org/10.1159/000086885
  13. Skwarek, A., Grodzicki, M., Nyckowski, P., Kotulski, M., Zieniewicz, K., Michalowicz, B., Patkowski, W., Grzelak, I., Paczkowska, A., Giercuszkiewicz, D., Sańko-Resmer, J., Pączek, L., & Krawczyk, M. (2006). The Use Prometheus FPSA System in the Treatment of Acute Liver Failure: Preliminary Results. Transplantation Proceedings, 38(1), 209–211. https://doi.org/10.1016/j.transproceed.2005.12.011
  14. Rifai, K., Ernst, T., Kretschmer, U., Hafer, C., Haller, H., Manns, M. P., & Fliser, D. (2005). The Prometheus<sup>®</sup> Device for Extracorporeal Support of Combined Liver and Renal Failure. Blood Purification, 23(4), 298–302. https://doi.org/10.1159/000086552
  15. Santoro, A., Mancini, E., Ferramosca, E., & Faenza, S. (2007). Liver Support Systems. In Contributions to Nephrology (pp. 396–404). KARGER. https://doi.org/10.1159/000102130
  16. Liu, J., Kjaergard, L. L., Als‐Nielsen, B., & Gluud, C. (2002). Artificial and bioartificial support systems for liver failure: a Cochrane Hepato‐Biliary Group Protocol. Liver, 22(5), 433–438. https://doi.org/10.1034/j.1600-0676.2002.01554.x
  17. Rifai, K., Hafer, C., Rosenau, J., Athmann, C., Haller, H., Peter Manns, M., & Fliser, D. (2006). Treatment of severe refractory pruritus with fractionated plasma separation and adsorption (Prometheus®). Scandinavian Journal of Gastroenterology, 41(10), 1212–1217. https://doi.org/10.1080/00365520600610154
  18. Meijers, B. K. I., Verhamme, P., Nevens, F., Hoylaerts, M. F., Bammens, B., Wilmer, A., Arnout, J., Vanrenterghem, Y., & Evenepoel, P. (2007). Major Coagulation Disturbances During Fractionated Plasma Separation and Adsorption. American Journal of Transplantation, 7(9), 2195–2199. https://doi.org/10.1111/j.1600-6143.2007.01909.x