Skip to main
Navigated percutaneous pelvic sacroiliac screw fixation: Experimental comparison of accuracy between fluoroscopy and Iso-C 3D navigation
Additional details
- Orthopedic Trauma Association Committee for Coding and Classification. (1996) Fracture and dislocation compendium J Orthop Trauma, 10, pp. V - IX.
- Pohlemann, T.(2001) Pelvic ring injuries: assessment and concepts of surgical management. In AO Principles of Fracture Management. ( pp. 391 - 413 ). Stuttgart : Thieme.
- Routt, M, Jr and Simonian, P and Swiontkowski, M. (1997) Stabilization of pelvic ring disruptions Orthop Clin North Am, 28, pp. 369 - 388.
- Tile, M. (1999) The management of unstable injuries of the pelvic ring [editorial; comment] J Bone Joint Surg Br, 81, pp. 941 - 943.
- Matta, J and Saucedo, T. (1989) Internal fixation of pelvic ring fractures Clin Orthop(242), pp. 83 - 97.
- Gorczyca, J and Conner, J.(1996) A beginner's experience with percutaneous iliosacral screws. In Surgery of the Pelvis and Acetabulum: The 3rd International Consensus. . Pittsburgh PA October
- Routt, M, Jr and Simonian, P and Mills, W. (1997) Iliosacral screw fixation: early complications of the percutaneous technique J Orthop Trauma, 11, pp. 584 - 589.
- Culemann, U and Pohlemann, T and Hüfner, T and Gänsslen, A. (2000) Dreidimensionale Bewegungsanalyse nach interner Stabilisierung von Beckenringfrakturen ‐ eine Computersimulation Unfallchirurg, 103, pp. 965 - 971.
- Hüfner, T and Pohlemann, T and Gänsslen, A and Geerling, J and Krettek, C and Tscherne, H. (1999) Computer assisted surgery (CAS) for correction of a malhealed pelvic ring fracture in a young female patient (abstract) Comput Aided Surg, 4, pp. 154.
- Hüfner, T and Geerling, J and Kfuri, M, Jr and Gänsslen, A and Citak, M and Kirchhoff, T and Sott, A and Krettek, C. (2003) Computer assisted pelvic surgery: registration based on a modified external fixator Comput Aided Surg, 8, pp. 192 - 197.
- Kahler, D and Zura, R and Mallik, K.(2000). Computer guided placement of iliosacral screws compared to standard fluoroscopic technique. Proceedings of the 5th Symposium on CAOS Computer Assisted Orthopaedic Surgery DavosSwitzerlandFebruary. In [ pp. ] . .
- Stockle, U and Konig, B and Dahne, M and Raschke, M and Haas, N. (2002) [Computer assisted pelvic and acetabular surgery. Clinical experiences and indications] Unfallchirurg, 105, pp. 886 - 892.
- Amiot, L and Poulin, F. (2004) Computed tomography-based navigation for hip, knee, and spine surgery Clin Orthop Rel Res(421), pp. 77 - 86.
- Laine, T and Mäkitalo, K and Schlenzka, D and Tallroth, K and Poussa, M and Alho, A. (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients Eur Spine J, 6, pp. 402 - 405.
- Hofstetter, R and Slomczykowski, M and Krettek, C and Köppen, G and Sati, M and Nolte, L-P. (2000) Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction Comput Aided Surg, 5, pp. 311 - 325.
- Euler, E and Heining, S and Riquarts, C and Mutschler, W. (2003) C-arm-based three-dimensional navigation: a preliminary feasibility study Comput Aided Surg, 8, pp. 35 - 41.
- Hufner, T and Gebhard, F and Grutzner, P and Messmer, P and Stockle, U and Krettek, C. (2004) Which navigation when? Injury, 35(Suppl 1), pp. S-A30 - 34.
- Matta, J. (1996) Regarding safe and effective placement of iliosacral screws J Orthop Trauma, 10, pp. 514.
- Suhm, N and Jacob, A and Nolte, L-P and Regazzoni, P and Messmer, P.(2001). Surgical navigation reduces radiation doses during closed intramedullary nailing. Proceedings of the 14th International Congress and Exhibition (CARS 2000) San FranciscoCA28 June-1 July2000. In Computer Assisted Radiology and Surgery.[ pp. 262 - 266] . .
- Hufner, T and Kfuri, M, Jr and Galanski, M and Bastian, L and Loss, M and Pohlemann, T and Krettek, C. (2004) New indications for computer-assisted surgery: tumor resection in the pelvis Clin Orthop(426), pp. 219 - 225.
- Mosheiff, R and Khoury, A and Weil, Y and Liebergall, M. (2004) First generation computerized fluoroscopic navigation in percutaneous pelvic surgery J Orthop Trauma, 18, pp. 106 - 111.
- Jacob, A and Regazzoni, P and Steinbrich, W and Messmer, P. (2000) The multifunctional therapy room of the future: image guidance, interdisciplinarity, integration and impact on patient pathways Eur Radiol, 10, pp. 1763 - 1769.
-
https://doi.org/10.3238/arztebl.2020.0793
-
Kendoff, D., Citak, M., Gardner, M. J., Stübig, T., Krettek, C., & Hüfner, T. (2007). Improved accuracy of navigated drilling using a drill alignment device. Journal of Orthopaedic Research, 25(7), 951–957.
https://doi.org/10.1002/jor.20383