Published January 25, 2019 | Journal article | Version v1 | https://doi.org/10.1186/s12879-019-3717-9

Improving natural ventilation in hospital waiting and consulting rooms to reduce nosocomial tuberculosis transmission risk in a low resource setting

Additional details

Funding

Wellcome Trust
070005/Z/02/Z
Wellcome Trust
064672
ROR icon Wellcome Trust
The prevention of airborne TB transmission. 070005

Dates

Issued
January 25, 2019

References

  1. Menzies D, Fanning A, Yuan L, Fitzgerald M. Tuberculosis among health care workers. N Engl J Med. 1995;332(2):92–8. https://doi.org/10.1056/nejm199501123320206
  2. Joshi R, Reingold AL, Menzies D, Pai M. Tuberculosis among health-care workers in low- and middle-income countries: a systematic review. PLoS Med. 2006;3(12):e494. https://doi.org/10.1371/journal.pmed.0030494
  3. Story A, Murad S, Roberts W, Verheyen M, Hayward AC. Tuberculosis in London: the importance of homelessness, problem drug use and prison. Thorax. 2007;62(8):667–71. https://doi.org/10.1136/thx.2006.065409
  4. Nardell E, McInnis B, Thomas B, Weidhaas S. Exogenous reinfection with tuberculosis in a shelter for the homeless. N Engl J Med. 1986;315(25):1570–5. https://doi.org/10.1056/nejm198612183152502
  5. Ewer, K., Deeks, J., Alvarez, L., Bryant, G., Waller, S., Andersen, P., Monk, P., & Lalvani, A. (2003). Comparison of T-cell-based assay with tuberculin skin test for diagnosis of Mycobacterium tuberculosis infection in a school tuberculosis outbreak. The Lancet, 361(9364), 1168–1173. https://doi.org/10.1016/s0140-6736(03)12950-9
  6. Daley CL, Small PM, Schecter GF, Schoolnik GK, McAdam RA, Jacobs WR Jr, Hopewell PC. An outbreak of tuberculosis with accelerated progression among persons infected with the human immunodeficiency virus. An analysis using restriction-fragment-length polymorphisms. N Engl J Med. 1992;326(4):231–5. https://doi.org/10.1056/nejm199201233260404
  7. Bock NN, Jensen PA, Miller B, Nardell E. Tuberculosis infection control in resource-limited settings in the era of expanding HIV care and treatment. J Infect Dis. 2007;196(Suppl 1):S108–13. https://doi.org/10.1086/518661
  8. Escombe AR, Moore DA, Gilman RH, Pan W, Navincopa M, Ticona E, Martinez C, Caviedes L, Sheen P, Gonzalez A, et al. The infectiousness of tuberculosis patients coinfected with HIV. PLoS Med. 2008;5(9):e188. https://doi.org/10.1371/journal.pmed.0050188
  9. Andrews, J. R., Shah, N. S., Gandhi, N., Moll, T., Friedland, G., & Collaboration, T. F. C. and R. (TF C. (2007). Multidrug‐Resistant and Extensively Drug‐Resistant Tuberculosis: Implications for the HIV Epidemic and Antiretroviral Therapy Rollout in South Africa. The Journal of Infectious Diseases, 196(s3), S482–S490. https://doi.org/10.1086/521121
  10. Gandhi NR, Moll A, Sturm AW, Pawinski R, Govender T, Lalloo U, Zeller K, Andrews J, Friedland G. Extensively drug-resistant tuberculosis as a cause of death in patients co-infected with tuberculosis and HIV in a rural area of South Africa. Lancet. 2006;368(9547):1575–80. https://doi.org/10.1016/s0140-6736(06)69573-1
  11. Riley RL, Nardell EA. Clearing the air. The theory and application of ultraviolet air disinfection. Am Rev Respir Dis. 1989;139(5):1286–94. https://doi.org/10.1164/ajrccm/139.5.1286
  12. Escombe AR, Oeser CC, Gilman RH, Navincopa M, Ticona E, Pan W, Martinez C, Chacaltana J, Rodriguez R, Moore DA, et al. Natural ventilation for the prevention of airborne contagion. PLoS Med. 2007;4(2):e68. https://doi.org/10.1371/journal.pmed.0040068
  13. Jensen PA, Lambert LA, Iademarco MF, Ridzon R. Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care settings, 2005. MMWR Recomm Rep. 2005;54(RR-17):1–141.
  14. WHO: Policy on TB infection control in health-care facilities, Congregate settings and households Geneva: World Health Organisation; 2009.
  15. Rouillon A, Perdrizet S, Parrot R. Transmission of tubercle bacilli: the effects of chemotherapy. Tubercle. 1976;57(4):275–99. https://doi.org/10.1016/s0041-3879(76)80006-2
  16. Menzies R, Schwartzman K, Loo V, Pasztor J. Measuring ventilation of patient care areas in hospitals. Description of a new protocol. Am J Respir Crit Care Med. 1995;152(6 Pt 1):1992–9. https://doi.org/10.1164/ajrccm.152.6.8520767
  17. Nardell EA, Keegan J, Cheney SA, Etkind SC. Airborne infection. Theoretical limits of protection achievable by building ventilation. Am Rev Respir Dis. 1991;144(2):302–6. https://doi.org/10.1164/ajrccm/144.2.302
  18. Menzies D. Effect of treatment on contagiousness of patients with active pulmonary tuberculosis. Infect Control Hosp Epidemiol. 1997;18(8):582–6. https://doi.org/10.2307/30141272
  19. Riley RL, Mills CC, O'Grady F, Sultan LU, Wittstadt F, Shivpuri DN. Infectiousness of air from a tuberculosis ward. Ultraviolet irradiation of infected air: comparative infectiousness of different patients. Am Rev Respir Dis. 1962;85:511–25.
  20. Long R, Zielinski M, Kunimoto D, Manfreda J. The emergency department is a determinant point of contact of tuberculosis patients prior to diagnosis. Int J Tuberc Lung Dis. 2002;6(4):332–9.
  21. Redd JT, Susser E. Controlling tuberculosis in an urban emergency department: a rapid decision instrument for patient isolation. Am J Public Health. 1997;87(9):1543–7. https://doi.org/10.2105/ajph.87.9.1543
  22. Sokolove PE, Lee BS, Krawczyk JA, Banos PT, Gregson AL, Boyce DM, Lewis RJ. Implementation of an emergency department triage procedure for the detection and isolation of patients with active pulmonary tuberculosis. Ann Emerg Med. 2000;35(4):327–36. https://doi.org/10.1016/s0196-0644(00)70050-3
  23. Escombe AR, Huaroto L, Ticona E, Burgos M, Sanchez I, Carrasco L, Farfán E, Flores F, Moore DA. Tuberculosis transmission risk and infection control in a hospital emergency department in Lima, Peru. Int J Tuberc Lung Dis. 2010;14(9):1120–6.
  24. Basu, S., Andrews, J. R., Poolman, E. M., Gandhi, N. R., Shah, N. S., Moll, A., Moodley, P., Galvani, A. P., & Friedland, G. H. (2007). Prevention of nosocomial transmission of extensively drug-resistant tuberculosis in rural South African district hospitals: an epidemiological modelling study. The Lancet, 370(9597), 1500–1507. https://doi.org/10.1016/s0140-6736(07)61636-5
  25. Escombe AR, Moore DA, Gilman RH, Navincopa M, Ticona E, Mitchell B, Noakes C, Martinez C, Sheen P, Ramirez R, et al. Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission. PLoS Med. 2009;6(3):e43. https://doi.org/10.1371/journal.pmed.1000043

1–25 of 33

Citations

  1. https://doi.org/10.3390/diseases14020055
  2. https://doi.org/10.3390/ijerph23020248
  3. Firoozi, A. A., & Firoozi, A. A. (2025). Architectural Innovations for Infection Control in Healthcare Environments: Spatial Strategies, Material Selection, and Ventilation Systems. In Transformative Design in Healthcare (pp. 47–79). Springer Nature Switzerland. https://doi.org/10.1007/978-3-032-08019-6_3
  4. Liu, F., Zhang, L., Chen, Z., Ma, J., Dong, Q., & Qian, H. (2025). Patient movement and ventilation effects on respiratory aerosol dynamics in hospital corridors: A combined CFD and field study. Building and Environment, 281, Article 113225. https://doi.org/10.1016/j.buildenv.2025.113225
  5. Gholampour, M., Taghipour, M., Tahavvor, A., & Jafari, S. (2025). Retrofitting of building with double skin façade to improve indoor air quality, thermal comfort, and infection control in inpatient wards of a hospital in a semi-hot-arid climate. Energy and Buildings, 332, 115365. https://doi.org/10.1016/j.enbuild.2025.115365
  6. Sarkar, M. (2025). Tuberculosis infection prevention and control. Indian Journal of Tuberculosis, 72(3), 394–400. https://doi.org/10.1016/j.ijtb.2024.08.011
  7. Shi, Y., Li, Y., Wang, R., & Li, X. (2025). A framework for optimizing the indoor spatial layout of outpatient building focusing on respiratory infection control by improving natural ventilation. Journal of Building Engineering, 104, 112352. https://doi.org/10.1016/j.jobe.2025.112352
  8. Zheng, Q., Li, Z., Ding, L., & Peng, C. (2025). Performance-driven multi-objective optimization for nursing unit design. Journal of Building Engineering, 116, 114679. https://doi.org/10.1016/j.jobe.2025.114679
  9. Walter, K. S., Lemos, E. F., Cavalcante Aires Alves, A. P., Chaves Ferreira, G. F., Martins Coutinho, V. M., Mathema, B., Warren, J. L., Colijn, C., Cohen, T., Croda, J., & Andrews, J. R. (2025). Mycobacterium tuberculosis transmission dynamics within prisons: a population-based genomic study. The Lancet Regional Health - Americas, 52, 101262. https://doi.org/10.1016/j.lana.2025.101262
  10. Arthur, R. F., Styczynski, A., Srinivasan, K., Tandanpolie, A., Bemah, P., Bell, E., Andrews, J. R., Baer, T., & Salinas, J. L. (2025). Effectiveness and acceptability of ventilation modifications in healthcare facilities, Liberia 2022–2023. Antimicrobial Stewardship & Healthcare Epidemiology, 5(1). https://doi.org/10.1017/ash.2025.10077
  11. Mellon, G., Mahjoub, N., Metivier, F., Osinski, N., Gabassi, A., Delaugerre, C., Vanoli, E., Crawford, C., & Le Goff, J. (2025). Enhancing the control of respiratory virus spread: a comprehensive approach integrating airborne virus detection, aerological investigations, and airflow modeling for practical implementation. Infection Control & Hospital Epidemiology, 46(3), 256–265. https://doi.org/10.1017/ice.2024.217
  12. Zong, J., Chang, Y., Hu, Y., & Ai, Z. (2025). Aerosol dispersion and energy consumption in a mechanically heated and cooled multi-chair dental office with windows routinely opened. Physics of Fluids, 37(4). https://doi.org/10.1063/5.0264026
  13. da Silva Paula, V. M., de Moraes Bruna, C. Q., Ciofi Silva, C. L., de Souza Hajar, K., Eduardo Galvão, C., & Uchikawa Graziano, K. (2025). Fractional exhaled nitric oxide and respiratory symptoms in central sterile supply department workers exposed to different ventilation systems. International Journal of Environmental Health Research, 35(9), 2574–2583. https://doi.org/10.1080/09603123.2025.2452299
  14. https://doi.org/10.1177/10591478251318920
  15. https://doi.org/10.2478/aiht-2025-76-4013
  16. https://doi.org/10.3390/air3040030
  17. https://doi.org/10.3390/buildings15071019
  18. https://doi.org/10.3390/ecm2030036
  19. https://doi.org/10.64898/2025.12.24.25342956
  20. https://doi.org/10.7554/elife.99200
  21. https://doi.org/10.7554/elife.99200.2
  22. https://doi.org/10.7554/elife.99200.3
  23. https://doi.org/10.7554/elife.99200.4
  24. https://doi.org/10.7759/cureus.81838
  25. Al-Rikabi, I. J., Karam, J., Alsaad, H., Ghali, K., Ghaddar, N., & Voelker, C. (2024). The impact of mechanical and natural ventilation modes on the spread of indoor airborne contaminants: A review. Journal of Building Engineering, 85, Article 108715. https://doi.org/10.1016/j.jobe.2024.108715

1–25 of 78