Published January 2021 | Journal article | Version v1 | https://doi.org/10.1186/s40634-021-00357-8

CT based PSI blocks for osteotomies around the knee provide accurate results when intraoperative imaging is used

Description

AbstractPurposeCorrection osteotomies around the knee are common methods for the treatment of varus or valgus malalignment of the lower extremity. In recent years, patient specific instrumentation (PSI) guides were introduced in order to enhance the accuracy of these procedures. The purpose of this study was to determine the accuracy of CT based PSI guides for correction osteotomies around the knee of low volume osteotomy surgeons and to evaluate if CT based PSI blocks deliver a high degree of accuracy without using intraoperative fluoroscopy.MethodsTwo study arms with CT based PSI cutting blocks for osteotomies around the knee were conducted. Part one: A retrospective analysis of 19 osteotomies was made in order to evaluate the accuracy in the hands of a low volume surgeon on long‐leg radiographs. Part two: A cadaveric study with 8 knees was performed for the purpose of analyzing the accuracy without using intraoperative fluoroscopy on pre‐ and postoperative CT scans. Hip‐Knee‐Ankle angle (HKA), lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were analyzed. The mean absolute delta (∂) between the planned and postoperative parameters were calculated. The accuracy of both study arms were compared.ResultsPart one: The mean MPTA ∂, LDFA ∂ and HKA ∂ was 0.9°, 1.9° and 1.5°, respectively. Part two: The mean MPTA ∂ and LDFA ∂ was 3.5° and 2.2°, respectively. The mean ∂ of MPTA is significantly different between clinical patients with fluoroscopic control and cadaveric specimens without fluoroscopic control (P < 0.001). All surgeries were performed without complications such as a hinge fracture.ConclusionThe clinical use of PSI guides for osteotomies around the knee in the hands of low volume surgeons is a safe procedure. The PSI guides deliver a reliable accuracy under fluoroscopic control whereas their non‐use of intraoperative fluoroscopy leads to a lack of accuracy. The use of fluoroscopic control during PSI guided correction osteotomies is highly recommended.Level of evidenceIV – Retrospective and experimental Study

Files

s40634-021-00357-8.pdf

Files (1.5 MB)

Name Size Download all
md5:53f2f938b30bd6b34367ce45a8cc1211
1.5 MB Preview Download

Additional details

Dates

Issued
January 2021

References

  1. https://doi.org/10.1007/s00167%E2%80%90012%E2%80%902122%E2%80%903 https://doi.org/10.1007/s00167%E2%80%90012%E2%80%902122%E2%80%903
  2. Arnal-Burró, J., Pérez-Mañanes, R., Gallo-del-Valle, E., Igualada-Blazquez, C., Cuervas-Mons, M., & Vaquero-Martín, J. (2017). Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: Do it yourself. The Knee, 24(6), 1359–1368. https://doi.org/10.1016/j.knee.2017.04.016
  3. https://doi.org/10.1302/0301%E2%80%90620x.91b9.22058 https://doi.org/10.1302/0301%E2%80%90620x.91b9.22058
  4. Boonen, B., Kerens, B., Schotanus, M. G. M., Emans, P., Jong, B., & Kort, N. P. (2016). Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan. The Knee, 23(1), 20–24. https://doi.org/10.1016/j.knee.2015.08.008
  5. ChaoucheS JacquetC Fabre‐AubrespyM SharmaA ArgensonJN ParratteSet al. Patient‐specific cutting guides for open‐wedge high tibial osteotomy: safety and accuracy analysis of a hundred patients continuous cohort.Int Orthop(2019)10.1007/s00264‐019‐04372‐431273430
  6. https://doi.org/10.1007/s00167%E2%80%90019%E2%80%9005404%E2%80%907 https://doi.org/10.1007/s00167%E2%80%90019%E2%80%9005404%E2%80%907
  7. https://doi.org/10.1007/s00167%E2%80%90015%E2%80%903730%E2%80%905 https://doi.org/10.1007/s00167%E2%80%90015%E2%80%903730%E2%80%905
  8. https://doi.org/10.1055/a%E2%80%900582%E2%80%908040 https://doi.org/10.1055/a%E2%80%900582%E2%80%908040
  9. https://doi.org/10.1186/s13018%E2%80%90018%E2%80%900872%E2%80%904 https://doi.org/10.1186/s13018%E2%80%90018%E2%80%900872%E2%80%904
  10. https://doi.org/10.1007/s11420%E2%80%90016%E2%80%909516%E2%80%906 https://doi.org/10.1007/s11420%E2%80%90016%E2%80%909516%E2%80%906
  11. Gulagaci, F., Jacquet, C., Ehlinger, M., Sharma, A., Kley, K., Wilson, A., Parratte, S., & Ollivier, M. (2019). A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy. Knee Surgery, Sports Traumatology, Arthroscopy, 28(10), 3173–3182. https://doi.org/10.1007/s00167-019-05806-7
  12. https://doi.org/10.1007/s00167%E2%80%90006%E2%80%900035%E2%80%908 https://doi.org/10.1007/s00167%E2%80%90006%E2%80%900035%E2%80%908
  13. https://doi.org/10.1016/s0720%E2%80%90048x(03)00178%E2%80%905 https://doi.org/10.1016/s0720%E2%80%90048x(03)00178%E2%80%905
  14. JacquetC Chan‐Yu‐KinJ SharmaA ArgensonJN ParratteS OllivierMMore accurate correction using "patient‐specific" cutting guides in opening wedge distal femur varization osteotomies.Int Orthop(2018)10.1007/s00264‐018‐4207‐130413851
  15. JacquetC SharmaA FabreM EhlingerM ArgensonJN ParratteSet al. Patient‐specific high‐tibial osteotomy's 'cutting‐guides' decrease operating time and the number of fluoroscopic images taken after a Brief Learning Curve.Knee Surg Sports Traumatol Arthrosc(2019)10.1007/s00167‐019‐05637‐631773202
  16. https://doi.org/10.1007/s00167%E2%80%90017%E2%80%904526%E2%80%906 https://doi.org/10.1007/s00167%E2%80%90017%E2%80%904526%E2%80%906
  17. Kim, Y. C., Yang, J.-H., Kim, H. J., Tawonsawatruk, T., Chang, Y. S., Lee, J. S., Bhandare, N. N., Kim, K. S., Delgado, G. D. G., & Nha, K. W. (2018). Distal Femoral Varus Osteotomy for Valgus Arthritis of the Knees: Systematic Review of Open versus Closed Wedge Osteotomy. Knee Surgery and Related Research, 30(1), 3–16. https://doi.org/10.5792/ksrr.16.064
  18. Lee, D. K., Kim, K. K., Ham, C. U., Yun, S. T., Kim, B. K., & Oh, K. J. (2018). The Learning Curve for Biplane Medial Open Wedge High Tibial Osteotomy in 100 Consecutive Cases Assessed Using the Cumulative Summation Method. Knee Surgery and Related Research, 30(4), 303–310. https://doi.org/10.5792/ksrr.17.064
  19. https://doi.org/10.1007/s00167%E2%80%90002%E2%80%900334%E2%80%907 https://doi.org/10.1007/s00167%E2%80%90002%E2%80%900334%E2%80%907
  20. Mannan, A., & Smith, T. O. (2016). Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis. The Knee, 23(2), 186–190. https://doi.org/10.1016/j.knee.2015.08.006
  21. Munier, M., Donnez, M., Ollivier, M., Flecher, X., Chabrand, P., Argenson, J.-N., & Parratte, S. (2017). Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study. Orthopaedics & Traumatology: Surgery & Research, 103(2), 245–250. https://doi.org/10.1016/j.otsr.2016.11.020
  22. https://doi.org/10.1055/s%E2%80%900036%E2%80%901572412 https://doi.org/10.1055/s%E2%80%900036%E2%80%901572412
  23. https://doi.org/10.1007/s00167%E2%80%90016%E2%80%904302%E2%80%90z https://doi.org/10.1007/s00167%E2%80%90016%E2%80%904302%E2%80%90z
  24. https://doi.org/10.3928/0147%E2%80%907447%E2%80%9020051002%E2%80%9013 https://doi.org/10.3928/0147%E2%80%907447%E2%80%9020051002%E2%80%9013
  25. https://doi.org/10.1055/a%E2%80%900824%E2%80%907603 https://doi.org/10.1055/a%E2%80%900824%E2%80%907603

1–25 of 32