Published January 2012 | Journal article | Version v1 | https://doi.org/10.1186/1532-429x-14-34

Perfusion cardiovascular magnetic resonance: Comparison of an advanced, high-resolution and a standard sequence

Additional details

Funding

ROR icon British Heart Foundation
RE/08/003
ROR icon European Commission
Personalised and intergrated cardiac care: \nPatient-specific Cardiovascular Modelling and Simulation for In Silico Disease Understanding and Management 224495
ROR icon Wellcome Trust
WT088641 ⁄Z ⁄ 09 ⁄ Z
ROR icon British Heart Foundation
True validation of quantitative myocardial perfusion magnetic resonance imaging FS/10/029/28253
ROR icon Wellcome Trust
King's College London Medical Engineering Centre. 088641/Z/09/Z
ROR icon University of Southampton
ROR icon Engineering and Physical Sciences Research Council

Dates

Issued
January 2012

References

  1. Prognostic Value of Cardiac Magnetic Resonance Stress Tests: Adenosine Stress Perfusion and Dobutamine Stress Wall Motion Imaging https://doi.org/10.1161/circulationaha.106.652016
  2. Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., & de Bruyne, B. (2007). Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis. Journal of the American College of Cardiology, 49(21), 2105–2111. https://doi.org/10.1016/j.jacc.2007.01.087
  3. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention https://doi.org/10.1056/nejmoa0807611
  4. Nandalur, K. R., Dwamena, B. A., Choudhri, A. F., Nandalur, M. R., & Carlos, R. C. (2007). Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease. Journal of the American College of Cardiology, 50(14), 1343–1353. https://doi.org/10.1016/j.jacc.2007.06.030
  5. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial https://doi.org/10.1093/eurheartj/ehm617
  6. Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography https://doi.org/10.1161/01.cir.103.18.2230
  7. Comparison of Hybrid Echo-planar Imaging and FLASH Myocardial Perfusion Cardiovascular MR Imaging https://doi.org/10.1148/radiol.2351040360
  8. Lyne, J. C., Gatehouse, P. D., Assomull, R. G., Smith, G. C., Kellman, P., Firmin, D. N., & Pennell, D. J. (2007). Direct comparison of myocardial perfusion cardiovascular magnetic resonance sequences with parallel acquisition. Journal of Magnetic Resonance Imaging, 26(6), 1444–1451. https://doi.org/10.1002/jmri.21167
  9. Weber, S., Kronfeld, A., Kunz, R. P., Fiebich, M., Horstick, G., Kreitner, K., & Schreiber, W. G. (2007). Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE). Journal of Magnetic Resonance Imaging, 26(3), 569–579. https://doi.org/10.1002/jmri.21047
  10. Fenchel, M., Helber, U., Simonetti, O. P., Stauder, N. I., Kramer, U., Nguyen, C., Finn, J. P., Claussen, C. D., & Miller, S. (2004). Multislice first‐pass myocardial perfusion imaging: Comparison of saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) and SR‐TurboFLASH‐2D pulse sequences. Journal of Magnetic Resonance Imaging, 19(5), 555–563. https://doi.org/10.1002/jmri.20050
  11. Wang, Y., Moin, K., Akinboboye, O., & Reichek, N. (2005). Myocardial first pass perfusion: Steady‐state free precession versus spoiled gradient echo and segmented echo planar imaging. Magnetic Resonance in Medicine, 54(5), 1123–1129. https://doi.org/10.1002/mrm.20700
  12. Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999). SENSE: Sensitivity encoding for fast MRI. Magnetic Resonance in Medicine, 42(5), 952–962. https://doi.org/10.1002/(sici)1522-2594(199911)42:5%3C952::aid-mrm16%3E3.0.co;2-s
  13. Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods https://doi.org/10.1186/1532-429x-10-29
  14. Assessment of regional left ventricular function: accuracy and reproducibility of positioning standard short-axis sections in cardiac MR imaging https://doi.org/10.1148/radiol.2351040249
  15. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance https://doi.org/10.1186/1532-429x-13-28
  16. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association https://doi.org/10.1161/hc0402.102975
  17. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial https://doi.org/10.1016/s0140-6736(11)61335-4
  18. Maredia, N., Radjenovic, A., Kozerke, S., Larghat, A., Greenwood, J. P., & Plein, S. (2010). Effect of improving spatial or temporal resolution on image quality and quantitative perfusion assessment with k‐t SENSE acceleration in first‐pass CMR myocardial perfusion imaging. Magnetic Resonance in Medicine, 64(6), 1616–1624. https://doi.org/10.1002/mrm.22493
  19. k-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: comparison with 1.5 T https://doi.org/10.1148/radiol.2492080017
  20. Manka, R., Vitanis, V., Boesiger, P., Flammer, A. J., Plein, S., & Kozerke, S. (2010). Clinical Feasibility of Accelerated, High Spatial Resolution Myocardial Perfusion Imaging. JACC: Cardiovascular Imaging, 3(7), 710–717. https://doi.org/10.1016/j.jcmg.2010.03.009
  21. Effects of missing dynamic images on myocardial perfusion reserve index calculation: comparison between an every heartbeat and an alternate heartbeat acquisition https://doi.org/10.1081/jcmr-120019420
  22. Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement https://doi.org/10.1081/jcmr-100107473
  23. Schreiber, W. G., Schmitt, M., Kalden, P., Mohrs, O. K., Kreitner, K., & Thelen, M. (2002). Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISP. Journal of Magnetic Resonance Imaging, 16(6), 641–652. https://doi.org/10.1002/jmri.10209
  24. Kellman, P., & McVeigh, E. R. (2005). Image reconstruction in SNR units: A general method for SNR measurement†. Magnetic Resonance in Medicine, 54(6), 1439–1447. https://doi.org/10.1002/mrm.20713
  25. Di Bella, E. V. R., Parker, D. L., & Sinusas, A. J. (2005). On the dark rim artifact in dynamic contrast‐enhanced MRI myocardial perfusion studies. Magnetic Resonance in Medicine, 54(5), 1295–1299. https://doi.org/10.1002/mrm.20666

1–25 of 26