Perfusion cardiovascular magnetic resonance: Comparison of an advanced, high-resolution and a standard sequence
Authors/Creators
Additional details
Identifiers
Funding
-
British Heart Foundation
- RE/08/003
-
European Commission
- Personalised and intergrated cardiac care: \nPatient-specific Cardiovascular Modelling and Simulation for In Silico Disease Understanding and Management 224495
-
Wellcome Trust
- WT088641 ⁄Z ⁄ 09 ⁄ Z
-
British Heart Foundation
- True validation of quantitative myocardial perfusion magnetic resonance imaging FS/10/029/28253
-
Wellcome Trust
- King's College London Medical Engineering Centre. 088641/Z/09/Z
-
University of Southampton
-
Engineering and Physical Sciences Research Council
Dates
- Issued
-
January 2012
References
- Prognostic Value of Cardiac Magnetic Resonance Stress Tests: Adenosine Stress Perfusion and Dobutamine Stress Wall Motion Imaging https://doi.org/10.1161/circulationaha.106.652016
- Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., & de Bruyne, B. (2007). Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis. Journal of the American College of Cardiology, 49(21), 2105–2111. https://doi.org/10.1016/j.jacc.2007.01.087
- Fractional flow reserve versus angiography for guiding percutaneous coronary intervention https://doi.org/10.1056/nejmoa0807611
- Nandalur, K. R., Dwamena, B. A., Choudhri, A. F., Nandalur, M. R., & Carlos, R. C. (2007). Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease. Journal of the American College of Cardiology, 50(14), 1343–1353. https://doi.org/10.1016/j.jacc.2007.06.030
- MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial https://doi.org/10.1093/eurheartj/ehm617
- Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography https://doi.org/10.1161/01.cir.103.18.2230
- Comparison of Hybrid Echo-planar Imaging and FLASH Myocardial Perfusion Cardiovascular MR Imaging https://doi.org/10.1148/radiol.2351040360
- Lyne, J. C., Gatehouse, P. D., Assomull, R. G., Smith, G. C., Kellman, P., Firmin, D. N., & Pennell, D. J. (2007). Direct comparison of myocardial perfusion cardiovascular magnetic resonance sequences with parallel acquisition. Journal of Magnetic Resonance Imaging, 26(6), 1444–1451. https://doi.org/10.1002/jmri.21167
- Weber, S., Kronfeld, A., Kunz, R. P., Fiebich, M., Horstick, G., Kreitner, K., & Schreiber, W. G. (2007). Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE). Journal of Magnetic Resonance Imaging, 26(3), 569–579. https://doi.org/10.1002/jmri.21047
- Fenchel, M., Helber, U., Simonetti, O. P., Stauder, N. I., Kramer, U., Nguyen, C., Finn, J. P., Claussen, C. D., & Miller, S. (2004). Multislice first‐pass myocardial perfusion imaging: Comparison of saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) and SR‐TurboFLASH‐2D pulse sequences. Journal of Magnetic Resonance Imaging, 19(5), 555–563. https://doi.org/10.1002/jmri.20050
- Wang, Y., Moin, K., Akinboboye, O., & Reichek, N. (2005). Myocardial first pass perfusion: Steady‐state free precession versus spoiled gradient echo and segmented echo planar imaging. Magnetic Resonance in Medicine, 54(5), 1123–1129. https://doi.org/10.1002/mrm.20700
- Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999). SENSE: Sensitivity encoding for fast MRI. Magnetic Resonance in Medicine, 42(5), 952–962. https://doi.org/10.1002/(sici)1522-2594(199911)42:5%3C952::aid-mrm16%3E3.0.co;2-s
- Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods https://doi.org/10.1186/1532-429x-10-29
- Assessment of regional left ventricular function: accuracy and reproducibility of positioning standard short-axis sections in cardiac MR imaging https://doi.org/10.1148/radiol.2351040249
- Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance https://doi.org/10.1186/1532-429x-13-28
- Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association https://doi.org/10.1161/hc0402.102975
- Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial https://doi.org/10.1016/s0140-6736(11)61335-4
- Maredia, N., Radjenovic, A., Kozerke, S., Larghat, A., Greenwood, J. P., & Plein, S. (2010). Effect of improving spatial or temporal resolution on image quality and quantitative perfusion assessment with k‐t SENSE acceleration in first‐pass CMR myocardial perfusion imaging. Magnetic Resonance in Medicine, 64(6), 1616–1624. https://doi.org/10.1002/mrm.22493
- k-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: comparison with 1.5 T https://doi.org/10.1148/radiol.2492080017
- Manka, R., Vitanis, V., Boesiger, P., Flammer, A. J., Plein, S., & Kozerke, S. (2010). Clinical Feasibility of Accelerated, High Spatial Resolution Myocardial Perfusion Imaging. JACC: Cardiovascular Imaging, 3(7), 710–717. https://doi.org/10.1016/j.jcmg.2010.03.009
- Effects of missing dynamic images on myocardial perfusion reserve index calculation: comparison between an every heartbeat and an alternate heartbeat acquisition https://doi.org/10.1081/jcmr-120019420
- Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement https://doi.org/10.1081/jcmr-100107473
- Schreiber, W. G., Schmitt, M., Kalden, P., Mohrs, O. K., Kreitner, K., & Thelen, M. (2002). Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISP. Journal of Magnetic Resonance Imaging, 16(6), 641–652. https://doi.org/10.1002/jmri.10209
- Kellman, P., & McVeigh, E. R. (2005). Image reconstruction in SNR units: A general method for SNR measurement†. Magnetic Resonance in Medicine, 54(6), 1439–1447. https://doi.org/10.1002/mrm.20713
- Di Bella, E. V. R., Parker, D. L., & Sinusas, A. J. (2005). On the dark rim artifact in dynamic contrast‐enhanced MRI myocardial perfusion studies. Magnetic Resonance in Medicine, 54(5), 1295–1299. https://doi.org/10.1002/mrm.20666
1–25 of 26
Citations
- Adam, N., Mooiweer, R., Tyler, A., Kunze, K., Neji, R., Speier, P., Stäb, D., Ng, J., Kuriakose, S., Razavi, R., Nazir, M. S., Chiribiri, A., & Roujol, S. (2025). Three-dimensional motion corrected free-breathing simultaneous multislice-balanced steady state free precession myocardium perfusion imaging. Journal of Cardiovascular Magnetic Resonance, 27(2), 101897. https://doi.org/10.1016/j.jocmr.2025.101897
- https://doi.org/10.1186/s41824-019-0062-6
- Feisst, A., Kuetting, D. L. R., Dabir, D., Luetkens, J., Homsi, R., Schild, H. H., & Thomas, D. (2018). Influence of observer experience on cardiac magnetic resonance strain measurements using feature tracking and conventional tagging. IJC Heart & Vasculature, 18, 46–51. https://doi.org/10.1016/j.ijcha.2018.02.007
- https://doi.org/10.2196/medinform.9171
- https://doi.org/10.2196/preprints.9171
- https://doi.org/10.1097/rli.0000000000000274
- https://doi.org/10.1515/jim-2016-0069
- https://doi.org/10.1186/s12968-015-0124-2
- Sammut, E., Zarinabad, N., Vianello, P. F., & Chiribiri, A. (2014). Quantitative Assessment of Perfusion – Where Are We Now?. Current Cardiovascular Imaging Reports, 7(7). https://doi.org/10.1007/s12410-014-9278-9
- https://doi.org/10.2217/fca.14.18
- https://doi.org/10.1161/circimaging.112.000151