Concordance of HbA1c , creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self‐collected capillary blood samples sent by mail
Authors/Creators
- 1. Department of General Practice University Medical Center Göttingen Germany
- 2. Department of Clinical Chemistry and Interdisciplinary UMG Laboratory University Medical Center Göttingen Göttingen Germany
- 3. Department of Rheumatology and Immunology Hannover Medical School Hannover Germany
-
4.
German Center for Infection Research
-
5.
Medizinische Hochschule Hannover
- 6. Interdisciplinary UMG‐Laboratories and Department of Hematology and Medical Oncology University Medical Center Göttingen Göttingen Germany
-
7.
Michigan State University
- 8. Department of Pediatric Pneumology, Allergology, and Neonatology Hannover Medical School Hannover Germany
-
9.
German Center for Lung Research
Description
ABSTRACT Introduction/Aims Self‐collected capillary blood sampling with postal shipment may improve access to routine monitoring of HbA1c, creatinine, and lipid parameters, but evidence on concordance with venous samples under real‐world transport conditions remains limited. This study evaluated the concordance of HbA1c, creatinine, and lipid parameters between self‐collected mailed capillary samples, mailed venous samples, and courier‐transported venous samples. Material and Methods In this cross‐sectional study, participants scheduled for a blood draw in a general practice office self‐collected a capillary blood sample using the Tasso+ device and provided additional venous blood samples. One venous sample was sent by mail (VMS) with the capillary blood sample (CMS). The other venous sample was couriered directly to the laboratory (VCS). HbA1c, creatinine, LDL, HDL, and total cholesterol were measured. Results Samples of 105 participants were analyzed. High concordance was observed between CMS and VCS for HbA1c (absolute mean bias = 0.028%, relative mean bias = 0.463%, concordance correlation coefficient [CCC] = 0.999) and creatinine (absolute mean bias = 0.037 mg/dL, relative mean bias = 4.815%, CCC = 0.972). VMS showed high agreement with VCS for HbA1c (absolute mean bias = 0.028%, relative mean bias = 0.450%, CCC = 0.998) and creatinine (absolute mean bias = 0.026 mg/dL, relative mean bias = 3.320%, CCC = 0.990). Lipid parameters demonstrated good concordance for CMS and VMS compared to VCS, with relative bias values ranging from 3.0% to 5.7% and CCCs >0.95. Conclusions Self‐collected mailed capillary blood samples provide comparable HbA1c, creatinine, and lipid parameters to venous samples, even when sent by standard mail. Capillary self‐sampling is a reliable method for remote monitoring of these parameters in diabetes management and screening.
Additional details
Identifiers
- OpenAlex
- W7164900237
- PMID
- 42301151
- URL
- https://onlinelibrary.wiley.com/doi/10.1111/jdi.70359
Funding
- European Social Fund Plus
- ZAM 5‐87006761
Dates
- Issued
-
June 16, 2026
References
- Committee, A. D. A. P. P., ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Cusi, K., Ekhlaspour, L., Fleming, T. K., Hilliard, M. E., Johnson, E. L., Khunti, K., Lingvay, I., Matfin, G., McCoy, R. G., Napoli, N., Perry, M. L., Pilla, S. J., Polsky, S., … Gabbay, R. A. (2023). 4. Comprehensive Medical Evaluation and Assessment of Comorbidities: Standards of Care in Diabetes—2024. Diabetes Care, 47(Supplement_1), S52–S76. https://doi.org/10.2337/dc24-s004
- Nephrology, . the I. D. S. and . the I. S. of ., Pugliese, G., Penno, G., Natali, A., Barutta, F., Di Paolo, S., Reboldi, G., Gesualdo, L., & De Nicola, L. (2019). Diabetic kidney disease: new clinical and therapeutic issues. Joint position statement of the Italian Diabetes Society and the Italian Society of Nephrology on “The natural history of diabetic kidney disease and treatment of hyperglycemia in patients with type 2 diabetes and impaired renal function”. Journal of Nephrology, 33(1), 9–35. https://doi.org/10.1007/s40620-019-00650-x
- Radcliffe, N. J., Seah, J., Clarke, M., MacIsaac, R. J., Jerums, G., & Ekinci, E. I. (2016). Clinical predictive factors in diabetic kidney disease progression. Journal of Diabetes Investigation, 8(1), 6–18. https://doi.org/10.1111/jdi.12533
- Committee, A. D. A. P. P., ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Das, S. R., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., Kosiborod, M. N., Lingvay, I., Matfin, G., McCoy, R. G., Perry, M. L., Pilla, S. J., Polsky, S., Prahalad, P., … Gabbay, R. A. (2023). 10. Cardiovascular Disease and Risk Management: Standards of Care in Diabetes—2024. Diabetes Care, 47(Supplement_1), S179–S218. https://doi.org/10.2337/dc24-s010
- Marx, N., Federici, M., Schütt, K., Müller-Wieland, D., Ajjan, R. A., Antunes, M. J., Christodorescu, R. M., Crawford, C., Di Angelantonio, E., Eliasson, B., Espinola-Klein, C., Fauchier, L., Halle, M., Herrington, W. G., Kautzky-Willer, A., Lambrinou, E., Lesiak, M., Lettino, M., McGuire, D. K., … Zeppenfeld, K. (2023). 2023 ESC Guidelines for the management of cardiovascular disease in patients with diabetes. European Heart Journal, 44(39), 4043–4140. https://doi.org/10.1093/eurheartj/ehad192
- Committee, A. D. A. P. P., ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., Lingvay, I., Matfin, G., McCoy, R. G., Perry, M. L., Pilla, S. J., Polsky, S., Prahalad, P., Pratley, R. E., Segal, A. R., … Gabbay, R. A. (2023). 11. Chronic Kidney Disease and Risk Management: Standards of Care in Diabetes—2024. Diabetes Care, 47(Supplement_1), S219–S230. https://doi.org/10.2337/dc24-s011
- Liebl, A., Mata, M., & Eschwège, E. (2002). Evaluation of risk factors for development of complications in Type II diabetes in Europe. Diabetologia, 45(S1), S23–S28. https://doi.org/10.1007/s00125-002-0863-0
- Karter, A. J., Parker, M. M., Moffet, H. H., Ahmed, A. T., Ferrara, A., Liu, J. Y., & Selby, J. V. (2004). Missed Appointments and Poor Glycemic Control. Medical Care, 42(2), 110–115. https://doi.org/10.1097/01.mlr.0000109023.64650.73
- Consolazio, D., & Russo, A. G. (2025). Blood sugar, social struggles: Biomarkers of socioeconomic, gender, and ethnic health disparities in type 2 diabetes care. Social Science & Medicine, 383, 118435. https://doi.org/10.1016/j.socscimed.2025.118435
- Davila, E. P., Florez, H., Trepka, M. J., Fleming, L. E., Niyonsenga, T., Lee, D. J., & Parkash, J. (2011). Long work hours is associated with suboptimal glycemic control among US workers with diabetes. American Journal of Industrial Medicine, 54(5), 375–383. https://doi.org/10.1002/ajim.20923
- Committee, A. D. A. P. P., ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Ebekozien, O., Echouffo-Tcheugui, J. B., Ekhlaspour, L., Garg, R., Khunti, K., Lal, R., Lingvay, I., Matfin, G., Pandya, N., Pekas, E. J., Pilla, S. J., … Bannuru, R. R. (2024). 1. Improving Care and Promoting Health in Populations: Standards of Care in Diabetes—2025. Diabetes Care, 48(Supplement_1), S14–S26. https://doi.org/10.2337/dc25-s001
- Holman, H., Müller, F., Bhangu, N., Kottutt, J., & Alshaarawy, O. (2023). Impact of limited English proficiency on the control of diabetes and associated cardiovascular risk factors. The National Health and Nutrition Examination Survey, 2003–2018. Preventive Medicine, 167, 107394. https://doi.org/10.1016/j.ypmed.2022.107394
- Levy, N. K., Park, A., Solis, D., Hu, L., Langford, A. T., Wang, B., & Rogers, E. S. (2022). Social Determinants of Health and Diabetes-Related Distress in Patients With Insulin-Dependent Type 2 Diabetes: Cross-sectional, Mixed Methods Approach. JMIR Formative Research, 6(10), e40164. https://doi.org/10.2196/40164
- Brewster, S., Bartholomew, J., Holt, R. I. G., & Price, H. (2020). Non‐attendance at diabetes outpatient appointments: a systematic review. Diabetic Medicine, 37(9), 1427–1442. https://doi.org/10.1111/dme.14241
- Schnell, O., Crocker, J. B., & Weng, J. (2016). Impact of HbA1c Testing at Point of Care on Diabetes Management. Journal of Diabetes Science and Technology, 11(3), 611–617. https://doi.org/10.1177/1932296816678263
- Groenendijk, W. N., Griffin, T. P., Islam, M. N., Blake, L., Wall, D., Bell, M., & O'Shea, P. M. (2022). Remote capillary blood collection for HbA1c measurement during the COVID‐19 pandemic: A laboratory and patient perspective. Diabetic Medicine, 39(8). https://doi.org/10.1111/dme.14897
- Schmetzer, C., Vogt, E., Stellar, L., Godonou, E.-T., Liphardt, A.-M., Muehlensiepen, F., Vuillerme, N., Hueber, A. J., Kleyer, A., Krönke, G., Schett, G., Simon, D., & Knitza, J. (2022). Self-collection of capillary blood and saliva to determine COVID-19 vaccine immunogenicity in patients with immune-mediated inflammatory diseases and health professionals. Frontiers in Public Health, 10. https://doi.org/10.3389/fpubh.2022.994770
- https://doi.org/10.1136/rmdopen%E2%80%902022%E2%80%90002641 https://doi.org/10.1136/rmdopen%E2%80%902022%E2%80%90002641
- Woods, K., Douketis, J. D., Schnurr, T., Kinnon, K., Powers, P., & Crowther, M. A. (2004). Patient preferences for capillary vs. venous INR determination in an anticoagulation clinic: a randomized controlled trial. Thrombosis Research, 114(3), 161–165. https://doi.org/10.1016/j.thromres.2004.05.013
- Serafin, A., Malinowski, M., & Prażmowska-Wilanowska, A. (2020). Blood volume and pain perception during finger prick capillary blood sampling: are all safety lancets equal?. Postgraduate Medicine, 132(3), 288–295. https://doi.org/10.1080/00325481.2020.1717160
- Collier, B. B., Brandon, W. C., Chappell, M. R., Iacovetti, G., Tokunaga, N., Schaff, U. Y., Sommer, G. J., & Grant, R. P. (2025). Comparing capillary blood collection technologies: assessing patient experience, device performance, & clinical accuracy. Bioanalysis, 17(21), 1329–1336. https://doi.org/10.1080/17576180.2025.2580284
- Kurstjens, S., den Besten, M. J., van Dartel, D. A. M., van Gend, M. C. C., Meerts, L., & Hoedemakers, R. M. J. (2023). Validation of the Hem-Col capillary blood collection system for routine laboratory analyses. Scandinavian Journal of Clinical and Laboratory Investigation, 83(8), 604–607. https://doi.org/10.1080/00365513.2024.2301779
- Nathan, D. M., Krause-Steinrauf, H., Braffett, B. H., Arends, V. L., Younes, N., McGee, P., Lund, C., Johnson, M., Lorenzi, G., Gao, X., Steffes, M. W., Lachin, J. M., Group, . the G. R., Group, . the D. R., & Moser, O. (2021). Comparison of central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studies. PLOS ONE, 16(11), e0257154. https://doi.org/10.1371/journal.pone.0257154
- Larsen, M. lytken . (1986). Evaluation of a new capillary blood collection system for laboratory assay of glycated haemoglobin. Scandinavian Journal of Clinical and Laboratory Investigation, 46(4), 315–317. https://doi.org/10.3109/00365518609083676
- Beck, R. W., Bocchino, L. E., Lum, J. W., Kollman, C., Barnes-Lomen, V., Sulik, M., Haller, M. J., Bode, B., Cernich, J. T., Killeen, A. A., Garg, U., Liljenquist, D., Adams, J. G., Clements, M., Gabrielson, D., Johnson, T., & Clements, M. A. (2021). An Evaluation of Two Capillary Sample Collection Kits for Laboratory Measurement of HbA1c. Diabetes Technology & Therapeutics, 23(8), 537–545. https://doi.org/10.1089/dia.2021.0023
1–25 of 51
Citations
- Schröder, D., Kuhnke, L., Hoffmeister, L., Schuchardt, C., Hummers, E., Behrens, G. M. N., Stölting, A., Stankov, M., Dopfer-Jablonka, A., Happle, C., & Müller, F. (2027). Capillary self-blood collection for centralized testing – a pan-European cross-sectional pilot study. Clinica Chimica Acta, 594, Article 122911. https://doi.org/10.1016/j.cca.2026.122911
- Woolley, T., Rutter, E., Fitzgerald, L., & Young, N. (2026). Large-scale analysis of lipoprotein(a) levels in a UK-wide population, including analyte stability and comparability between capillary and venous samples: A feasibility study for home self-testing for personalized cardiovascular risk management. Journal of Patient Centricity, 1(2). https://doi.org/10.57264/jpc-2026-0013