Intraventricular Migration of an ICD Patch
Authors/Creators
Description
A 42‐year‐old man presented with fever and weight loss 12 months after ICD replacement. After unsuccessful search for an infected focus and a specific antibiotic treatment ICD pocket was explored and Staphylococcus epidermidis was cultured. Following generator explanation fever recurred and at a second operation one ICD patch was found to have perforated in the right ventricular cavity. Explanation of the patches was performed on cardiopulmo‐nary bypass, the patient survived the operation and infection was eradicated.
Additional details
Identifiers
Dates
- Issued
-
November 1990
References
- Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A. (1985). Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation, 71(2), 289–296. https://doi.org/10.1161/01.cir.71.2.289
- Olinger, G. N., Chapman, P. D., Troup, P. J., & Hossein Almassi, G. (1988). Stratified application of the automatic implantable cardioverter defibrillator. The Journal of Thoracic and Cardiovascular Surgery, 96(1), 141–149. https://doi.org/10.1016/s0022-5223(19)35307-3
- Influence of bacterial adherence to mtravascular catheters on in vitro antibiotic susceptibility
- KELLY, P. A., WALLACE, S., TUCKER, B., HURVITZ, R. J., ILVENTO, J., MIRABEL, G. S., & CANNOM, D. S. (1988). Postoperative Infection with the Automatic Implantable Cardioverter Defibrillator: Clinical Presentation and Use of the Gallium Scan in Diagnosis. Pacing and Clinical Electrophysiology, 11(8), 1220–1225. https://doi.org/10.1111/j.1540-8159.1988.tb03975.x
- Almassi, G. H., Olinger, G. N., Troup, P. J., Chapman, P. D., & Goodman, L. R. (1988). Delayed infection of the automatic implantable cardioverter-defibrillator. The Journal of Thoracic and Cardiovascular Surgery, 95(5), 908–911. https://doi.org/10.1016/s0022-5223(19)35705-8
- Siclari, F., Uhlschmind, G., Zwicky, P., & Turina, M. (1986). Intracolonic Migration of a Pacemaker Generator. The Thoracic and Cardiovascular Surgeon, 34(05), 338–339. https://doi.org/10.1055/s-2007-1022167
Citations
- Salih, A. M., Pshtiwan, L. R., Ali, H. O., Hassan, S. H., Jwamer, V. I., Latif, S., Hama, J. I., & kakamad, F. H. (2024). Unusual migration of implantable cardioverter defibrillator that clinically mimicking breast cancer: A case report. Radiology Case Reports, 19(2), 631–635. https://doi.org/10.1016/j.radcr.2023.11.018
- Schubmehl, H. B., Sun, H. H., Donington, J. S., Smith, D. E., & Grossi, E. A. (2017). An Old Solution for a New Problem: Eloesser Flap Management of Infected Defibrillator Patches. The Annals of Thoracic Surgery, 103(6), e497–e498. https://doi.org/10.1016/j.athoracsur.2016.11.049
- https://doi.org/10.1111/j.1540-8159.2004.00667.x
- Chilukuri, S., Herlihy, J. P., Massumkhani, G. A., Duncan, J. M., & Frazier, O. H. (2001). Implantable cardioverter defibrillator patch erosion in a heart transplant patient. The Annals of Thoracic Surgery, 72(1), 261–263. https://doi.org/10.1016/s0003-4975(00)02566-2
- https://doi.org/10.1111/j.1540-8159.1998.tb00038.x
- https://doi.org/10.1111/j.1540-8159.1998.tb01060.x
- https://doi.org/10.1378/chest.113.1.252
- Mulero, E., Karanam, R. N., & Krol, R. (1997). Migration of implantable cardioverter-defibrillator patch into the right atrium. The Journal of Thoracic and Cardiovascular Surgery, 113(5), 951–952. https://doi.org/10.1016/s0022-5223(97)70270-8
- Verheyden, C. N., Grothaus, P. C., & Lynch, D. J. (1996). Implantable Cardioverter-Defibrillator: Another Device to Cover. Plastic & Reconstructive Surgery, 97(Supplement), 944–951. https://doi.org/10.1097/00006534-199604001-00009
- https://doi.org/10.1111/j.1540-8159.1995.tb06977.x
- https://doi.org/10.1136/hrt.73.1.20
- Cox, J. N. (1994). Pathology of Cardiac Pacemakers and Central Catheters. In Current Topics in Pathology (pp. 199–271). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-76846-0_6
- Pfeiffer, D., Jung, W., Fehske, W., Korte, T., Manz, M., Moosdorf, R., & Lüderitz, B. (1994). Complications of pacemaker-defibrillator devices: Diagnosis and management. American Heart Journal, 127(4), 1073–1080. https://doi.org/10.1016/0002-8703(94)90090-6
- Vyhmeister, E. E., Razzouk, A. J., Van Arsdell, G. S., Torres, V. I., Gundry, S. R., & Bailey, L. L. (1994). Simple approach for extrapericardial placement of defibrillator patches via median sternotomy. The Annals of Thoracic Surgery, 57(5), 1341–1342. https://doi.org/10.1016/0003-4975(94)91397-8
- https://doi.org/10.1111/j.1540-8159.1994.tb02375.x
- https://doi.org/10.1111/j.1540-8167.1994.tb01135.x
- Birnbaum, P. L., Lichtenstein, S. V., Noble, W. H., Guslits, B. G., Kenney, B. D., Soutter, D. I., Panos, A. L., Dorian, P., & Newman, D. (1992). Bronchoenteric fistula from an infected internal cardioverter defibrillator. The Annals of Thoracic Surgery, 54(5), 987–988. https://doi.org/10.1016/0003-4975(92)90670-y
- Karwande, S. V., & Rowles, J. R. (1992). Bilateral anterior thoracotomy for automatic implantable cardioverter defibrillator placement in patients with previous sternotomy. The Annals of Thoracic Surgery, 54(4), 791–793. https://doi.org/10.1016/0003-4975(92)91037-a
- https://doi.org/10.1111/j.1540-8159.1992.tb05157.x