Published 2010 | Journal article | Version v1 | https://doi.org/10.1155/2010/978594

Investigation of Balance Function Using Dynamic Posturography under Electrical-Acoustic Stimulation in Cochlear Implant Recipients

Description

Introduction. The purpose of the present study is to investigate the effect of electrical-acoustic stimulation on vestibular function in CI patients by using the EquiTest and to help answer the question of whether electrically stimulating the inner ear using a cochlear implant influences the balance system in any way.Material and Methods. A test population () was selected at random from among the cochlear implant recipients. Dynamic posturography (using the EquiTest) was performed with the device switched off an switched on.Results. In summary, it can be said that an activated cochlear implant affects the function of the vestibular system and may, to an extent, even lead to a stabilization of balance function under the static conditions of dynamic posturography, but nevertheless also to a significant destabilization. Significant improvements in vestibular function were seen mainly in equilibrium scores under conditions 4 and 5, the composite equilibrium score, and the vestibular components as revealed by sensory analysis.Conclusions. Only under the static conditions are significantly poorer scores achieved when stimulation is applied. It may be that the explanation for any symptoms of dizziness lies precisely in the fact that they occur in supposedly noncritical situations, since, when the cochlear implant makes increased demands on the balance system, induced disturbances can be centrally suppressed.

Additional details

Dates

Issued
2010

References

  1. Cohen, N. L., & Hoffman, R. A. (1991). Complications of Cochlear Implant Surgery in Adults and Children. Annals of Otology, Rhinology & Laryngology, 100(9), 708–711. https://doi.org/10.1177/000348949110000903
  2. Van Den Broek, P., Huygen, P. L. M., Mens, L. H. M., Admiraal, R. J. C., & Spies, T. (1993). Vestibular Function in Cochlear Implant Patients. Acta Oto-Laryngologica, 113(3), 263–265. https://doi.org/10.3109/00016489309135806
  3. Kubo, T., Yamamoto, K.-. ichi ., Iwaki, T., Doi, K., & Tamura, M. (2001). Different forms of dizziness occurring after cochlear implant. European Archives of Oto-Rhino-Laryngology, 258(1), 9–12. https://doi.org/10.1007/pl00007519
  4. ITO, J. (1998). Influence of the Multichannel Cochlear Implant on Vestibular Function. Otolaryngology–Head and Neck Surgery, 118(6), 900–902. https://doi.org/10.1016/s0194-5998(98)70295-5
  5. Bance, M. L., O'Driscoll, M., Giles, E., & Ramsden, R. T. (1998). Vestibular Stimulation by Multichannel Cochlear Implants. The Laryngoscope, 108(2), 291–294. https://doi.org/10.1097/00005537-199802000-00025
  6. Nashner, L., Black, F., & Wall, C. (1982). Adaptation to altered support and visual conditions during stance: patients with vestibular deficits. The Journal of Neuroscience, 2(5), 536–544. https://doi.org/10.1523/jneurosci.02-05-00536.1982
  7. Huygen, P. L. M., Van Den Broek, P., Mens, L. H. M., Spies, T. H., & Admiraal, R. J. C. (1994). Does Intracochlear Implantation Jeopardize Vestibular Function?. Annals of Otology, Rhinology & Laryngology, 103(8), 609–614. https://doi.org/10.1177/000348949410300805
  8. Rossi, G., Solero, P., Rolando, M., & Bisetti, M. S. (1998). Vestibular Function and Cochlear Implant. ORL, 60(2), 85–87. https://doi.org/10.1159/000027570
  9. Coats, A. C. (1973). Effect of Varying Stimulus Parameters on the Galvanic Body-Sway Response. Annals of Otology, Rhinology & Laryngology, 82(1), 96–102. https://doi.org/10.1177/000348947308200119
  10. Moore, D. M., Hoffman, L. F., Beykirch, K., Honrubia, V., & Baloh, R. W. (1991). The electrically evoked vestibulo‐ocular reflex: I. normal subjects. Otolaryngology–Head and Neck Surgery, 104(2), 219–224. https://doi.org/10.1177/019459989110400210
  11. Hartmann, R., Topp, G., & Klinke, R. (1984). Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea. Hearing Research, 13(1), 47–62. https://doi.org/10.1016/0378-5955(84)90094-7
  12. Bordure, P., Desmadryl, G., Uziel, A., & Sans, A. (1989). Short latency vestibular potentials evoked by electrical round window stimulation in the guinea pig. Electroencephalography and Clinical Neurophysiology, 73(5), 464–469. https://doi.org/10.1016/0013-4694(89)90096-5

Citations

  1. Tashiro, H., Popovic, M. B., Dobrev, I., & Terasawa, Y. (2025). Artificial organs, tissues, and support systems. In Biomechatronics (pp. 211–239). Elsevier. https://doi.org/10.1016/b978-0-443-13862-1.00009-6
  2. Wang, R., Xu, K., Luo, J., Chao, X., Hu, F., Zhang, D., Chen, Y., Li, Y., Fan, Z., Wang, H., & Xu, L. (2024). Vestibular function and hearing preservation in children following a minimally invasive cochlear implantation. European Archives of Oto-Rhino-Laryngology, 281(8), 4029–4038. https://doi.org/10.1007/s00405-024-08504-4
  3. Hosseinzadeh, F., Asghari, A., Moradi‐Lakeh, M., Farhadi, M., Daneshi, A., Mohseni, M., & Mohammadi, S. S. (2020). Balance function after cochlear implant and inner ear anomaly: Comparison of dynamic posturography. Laryngoscope Investigative Otolaryngology, 5(3), 529–535. https://doi.org/10.1002/lio2.394
  4. Carpenter, M. G., & Campos, J. L. (2020). The Effects of Hearing Loss on Balance: A Critical Review. Ear & Hearing, 41(Supplement 1), 107S–119S. https://doi.org/10.1097/aud.0000000000000929
  5. Louza, J., Rösel, C., Gürkov, R., Krause, E., & Ihler, F. (2019). Influence of Cochlear Implantation on Postural Control and Risk of Falls. Audiology and Neurotology, 24(5), 245–252. https://doi.org/10.1159/000503165
  6. Hänsel, T., Gauger, U., Bernhard, N., Behzadi, N., Romo Ventura, M. E., Hofmann, V., Olze, H., Knopke, S., Todt, I., & Coordes, A. (2018). Meta‐analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation. The Laryngoscope, 128(9), 2110–2123. https://doi.org/10.1002/lary.27071
  7. Louza, J., Klappert, C. L., Ledderose, G., Gürkov, R., & Krause, E. (2018). Cochlear Implant Surgery and the Risk of Falls in an Adult Population. Otology & Neurotology, 39(2), e74–e79. https://doi.org/10.1097/mao.0000000000001656
  8. Gao, Y., Zhang, Q., Yan, J., Niu, X., Han, P., Yuan, H., Hu, J., Liu, B., & Xu, M. (2017). Sudden onset of static equilibrium dysfunction in patients receiving a cochlear implant. Medicine, 96(44), e8465. https://doi.org/10.1097/md.0000000000008465
  9. Rah, Y. C., Park, J. H., Park, J. H., Choi, B. Y., & Koo, J.-W. (2016). Dizziness and vestibular function before and after cochlear implantation. European Archives of Oto-Rhino-Laryngology, 273(11), 3615–3621. https://doi.org/10.1007/s00405-016-3988-3
  10. Parietti-Winkler, C., Lion, A., Montaut-Verient, B., Grosjean, R., & Gauchard, G. C. (2015). Effects of Unilateral Cochlear Implantation on Balance Control and Sensory Organization in Adult Patients with Profound Hearing Loss. BioMed Research International, 2015, 1–7. https://doi.org/10.1155/2015/621845
  11. Santos, T. G. T., Venosa, A. R., & Sampaio, A. L. L. (2015). Association between Hearing Loss and Vestibular Disorders: A Review of the Interference of Hearing in the Balance. International Journal of Otolaryngology and Head & Neck Surgery, 04(03), 173–179. https://doi.org/10.4236/ijohns.2015.43030
  12. Galeano, D., Brunetti, F., Torricelli, D., Piazza, S., & Pons, J. L. (2014). A Tool for Balance Control Training Using Muscle Synergies and Multimodal Interfaces. BioMed Research International, 2014, 1–13. https://doi.org/10.1155/2014/565370