Published September 1998 | Journal article | Version v1 | https://doi.org/10.1002/jor.1100160508

Deformation of femoral nails with intramedullary insertion

Description

AbstractCurrent methods of distal interlocking of intramedullary femoral nails are dependent on image intensification. However, radiation exposure to the patient, the operating room staff, and the surgeon remains a concern. Proximally mounted, radiation‐free aiming systems for distal interlocking of femoral nails have reportedly failed because of nail deformation with insertion. To better understand this deformation, a threedimensional magnetic motion tracking system was used to determine the position of the distal interlocking hole following nail insertion. The amount and direction of deformation of commercially available smalldiameter implants (unslotted 9‐mm nails inserted without reaming) and large‐diameter implants (slotted 13‐mm nails inserted with reaming) from a single manufacturer were analyzed. Measurements of deformation (three translations and three angles), based on the center of the distal transverse locking hole, were performed on 10 paired intact human cadaveric femora before and after insertion. The technique produced the following results for the small and large‐diameter nails, respectively: lateral translations of 18.1 ± 10.0 mm (mean ± SD, range: 47.8 mm) and 21.5 ± 7.9 mm (range: 26.4 mm), dorsal translations of ‐3.1 ± 4.3 mm (range: 15.2 mm) and 0.4 ± 9.8 mm (range: 30.1 mm), and rotation about the longitudinal axes of −0.1 ± 0.2° (range: 0.7°) and 10.0 ±3.1° (range: 7.8°). This technique is useful for measuring insertion‐related femoral nail deformation. The data for the nails tested suggest that a simple aiming arm, mounted on the proximal end of the femoral nail alone, will not sufficiently provide accurate distal aiming.

Additional details

Dates

Issued
September 1998

Citations

  1. Ollagnon, S., Maszelin, B., Hamcha, H., Pries, P., Lacroix, R., Marty Diloy, T., & Vendeuvre, T. (2026). Updated literature review of distal locking techniques for long femoral nails: Advantages and disadvantages. Injury, 57(3), 113063. https://doi.org/10.1016/j.injury.2026.113063
  2. https://doi.org/10.70675/2254bc71z8cd4z4526zbc3bzfd330089f577
  3. Su, Y., Li, Z., Zhang, C., Ai, X., Wu, B., Wang, Q., Ren, C., Ma, T., & Li, M. (2025). Application of TINAVI orthopedic robot-assisted proximal interlocking screw placement for femoral retrograde intramedullary nails: a retrospective clinical study. Journal of Robotic Surgery, 19(1). https://doi.org/10.1007/s11701-025-02787-3
  4. https://doi.org/10.1177/09544119251357640
  5. Spyrou, I. G., Rozis, M., Varsamos, I., & Pneumaticos, S. G. (2025). Nail-Retaining Derotation Osteotomy for Subtrochanteric Fracture Malunion: A Case Report and Review of the Literature. Cureus. https://doi.org/10.7759/cureus.95506
  6. https://doi.org/10.1186/s41205-024-00221-2
  7. https://doi.org/10.1142/s0219519423500732
  8. https://doi.org/10.12677/acm.2023.132283
  9. Bonnevialle, P. (2022). Fractura de la diáfisis femoral del adulto. Técnicas quirúrgicas. EMC - Técnicas Quirúrgicas - Ortopedia y Traumatología, 14(2), 1–15. https://doi.org/10.1016/s2211-033x(22)46402-4
  10. https://doi.org/10.1097/bto.0000000000000593
  11. https://doi.org/10.3390/s22093205
  12. Allard, A., Letissier, H., Le Nen, D., Dubrana, F., & Di Francia, R. (2021). Evaluation of the accuracy of the Sureshot® electromagnetic targeting system in distal locking of long-nailed humeral diaphyseal fractures. Orthopaedics & Traumatology: Surgery & Research, 107(2), 102785. https://doi.org/10.1016/j.otsr.2020.102785
  13. Allard, A., Letissier, H., Le Nen, D., Dubrana, F., & Di Francia, R. (2021). Évaluation de la précision du système de visée électromagnétique Sureshot® dans le verrouillage distal de l’enclouage centromédullaire long des fractures humérales diaphysaires. Revue de Chirurgie Orthopédique et Traumatologique, 107(2), 225–229. https://doi.org/10.1016/j.rcot.2020.11.014
  14. Bonnevialle, P. (2021). Frattura della diafisi femorale nell’adulto. Tecniche chirurgiche. EMC - Tecniche Chirurgiche - Chirurgia Ortopedica, 17(2), 1–15. https://doi.org/10.1016/s2211-0801(21)00011-x
  15. Maleki, M., Tehrani, A. F., Aray, A., & Ranjbar, M. (2021). Intramedullary nail holes laser indicator, a non-invasive technique for interlocking of intramedullary nails. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-00382-8
  16. https://doi.org/10.2147/ijgm.s321005
  17. Hsu, W., Yu, C., Chang, C., Wu, D., Yu, T., & Tseng, C. (2020). Implementation and performance evaluation of a drilling assistive device for distal locking of intramedullary nails. The International Journal of Medical Robotics and Computer Assisted Surgery, 16(4). https://doi.org/10.1002/rcs.2110
  18. Yu, J., Song, H., Park, C.-. woo ., Park, I., & Joung, S. (2020). Fluoroscopic images-based aiming and targeting system with two line lasers for insertion guidance of interlocking screw. International Journal of Computer Assisted Radiology and Surgery, 15(6), 1001–1012. https://doi.org/10.1007/s11548-020-02196-x
  19. https://doi.org/10.1111/os.12785
  20. https://doi.org/10.5005/jp-journals-10080-1437
  21. Ma, L., Zhao, Z., Zhang, B., Jiang, W., Fu, L., Zhang, X., & Liao, H. (2018). Three‐dimensional augmented reality surgical navigation with hybrid optical and electromagnetic tracking for distal intramedullary nail interlocking. The International Journal of Medical Robotics and Computer Assisted Surgery, 14(4). https://doi.org/10.1002/rcs.1909
  22. https://doi.org/10.1155/2018/4530386
  23. Azim, F. A. A. (2017). Radiation-Independent Distal Locking Screw Insertion using Dual Nail Insertion Handle: Is It a Reliable Method?. Journal of Orthopaedics, Trauma and Rehabilitation, 22(1), 30–33. https://doi.org/10.1016/j.jotr.2016.04.001
  24. https://doi.org/10.1097/md.0000000000007450
  25. https://doi.org/10.1371/journal.pone.0174407

1–25 of 64