Published 2013 | Book chapter | Version v1 | https://doi.org/10.1533/9780857097293.342

Applications: use of magnesium in medical applications

Authors/Creators

Additional details

Dates

Issued
2013

References

  1. First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12-month results
  2. In Vivo
  3. Biodegradable magnesium-alloy stent: current situation in research
  4. Clark, G. C. F., & Williams, D. F. (1982). The effects of proteins on metallic corrosion. Journal of Biomedical Materials Research, 16(2), 125–134. https://doi.org/10.1002/jbm.820160205
  5. Biomaterials and corrosion
  6. Eliezer, A., & Witte, F. (2010). Corrosion Behavior of Magnesium Alloys in Biomedical Environments. Advanced Materials Research, 95, 17–20. https://doi.org/10.4028/www.scientific.net/amr.95.17
  7. The role of biological environments on magnesium alloys as biomaterials
  8. Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., Ilsley, C., Böse, D., Koolen, J., Lüscher, T. F., Weissman, N., & Waksman, R. (2007). Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. The Lancet, 369(9576), 1869–1875. https://doi.org/10.1016/s0140-6736(07)60853-8
  9. Heffernan, E. J., Hayes, M. M., Alkubaidan, F. O., Clarkson, P. W., & Munk, P. L. (2008). Aggressive angiomyxoma of the thigh. Skeletal Radiology, 37(7), 673–678. https://doi.org/10.1007/s00256-008-0465-0
  10. Heublein, B., Rohde, R., Kaese, V., Niemeyer, M., Hartung, W., & Haverich, A. (2003). Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?. Heart, 89(6), 651–656. https://doi.org/10.1136/heart.89.6.651
  11. A new ligature?
  12. L'utilisation du magnésium comme matériel perdu dans l'ostéosynthèse
  13. Diffusion coefficients and solubility coefficients for gases in biological fluids and tissues: A review
  14. Mantovani, D., & Witte, F. (2010). Editorial. Acta Biomaterialia, 6(5), 1679–1679. https://doi.org/10.1016/j.actbio.2010.02.029
  15. Mueller, W., Fernández Lorenzo de Mele, M., Nascimento, M. L., & Zeddies, M. (2008). Degradation of magnesium and its alloys: Dependence on the composition of the synthetic biological media. Journal of Biomedical Materials Research Part A, 90A(2), 487–495. https://doi.org/10.1002/jbm.a.32106
  16. Mueller, W.-D., Lucia Nascimento, M., & Lorenzo de Mele, M. F. (2010). Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications☆. Acta Biomaterialia, 6(5), 1749–1755. https://doi.org/10.1016/j.actbio.2009.12.048
  17. Neumann, A. W., Hum, O. S., Francis, D. W., Zingg, W., & Van Oss, C. J. (1980). Kinetic and thermodynamic aspects of platelet adhesion from suspension to various substrates. Journal of Biomedical Materials Research, 14(4), 499–509. https://doi.org/10.1002/jbm.820140416
  18. Peuster, M., Fink, C., Wohlsein, P., Bruegmann, M., Günther, A., Kaese, V., Niemeyer, M., Haferkamp, H., & Schnakenburg, C. v . (2003). Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity. Biomaterials, 24(3), 393–399. https://doi.org/10.1016/s0142-9612(02)00352-6
  19. Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001). A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal—results 6–18 months after implantation into New Zealand white rabbits. Heart, 86(5), 563–569. https://doi.org/10.1136/heart.86.5.563
  20. Piiper, J., Canfield, R. E., & Rahn, H. (1962). Absorption of various inert gases from subcutaneous gas pockets in rats. Journal of Applied Physiology, 17(2), 268–274. https://doi.org/10.1152/jappl.1962.17.2.268
  21. Rettig, R., & Virtanen, S. (2008). Composition of corrosion layers on a magnesium rare‐earth alloy in simulated body fluids. Journal of Biomedical Materials Research Part A, 88A(2), 359–369. https://doi.org/10.1002/jbm.a.31887
  22. Rudee, M. L., & Price, T. M. (1985). The initial stages of adsorption of plasma derived proteins on artificial surfaces in a controlled flow environment. Journal of Biomedical Materials Research, 19(1), 57–66. https://doi.org/10.1002/jbm.820190106
  23. SEELIG, M. G. (1924). A STUDY OF MAGNESIUM WIRE AS AN ABSORBABLE SUTURE AND LIGATURE MATERIAL. Archives of Surgery, 8(2), 669. https://doi.org/10.1001/archsurg.1924.01120050210011
  24. Corrosion resistance of magnesium alloys
  25. Song, G. L., & Atrens, A. (1999). Corrosion Mechanisms of Magnesium Alloys. Advanced Engineering Materials, 1(1), 11–33. https://doi.org/10.1002/(sici)1527-2648(199909)1:1%3C11::aid-adem11%3E3.0.co;2-n

1–25 of 40