Ridge augmentation—The new field of computerized guided surgery: A technical note for minimal‐invasive bone splitting
Description
AbstractDifferent instrumentation procedures of the alveolar ridge expansion technique (ARST) with or without Guided Bone Regeneration have proven to be effective for successful implant placement in cases of alveolar bone width between 3mm and 6mm. Conventional bone splitting techniques require flap arising. This technical note demonstrates a method for flapless guided bone splitting. For this purpose, a newly developed surgical guide with internal irrigation channels was used.Using CAD‐CAM additive technology, a narrow slot along the field of interest and a pin of a cooling pipe was designed and implemented in a surgical guide template. The bone split was performed flapless through the surgical guide while the cooling pipe was connected to it.During surgery, the piezo‐driven instrument was moved within that slot, and the irrigation solution was directly rinsing it at point of entry through the irrigation channel. This procedure was performed on a 3.3 mm wide alveolar ridge achieving over 3 mm of bone gain.The described method combines several positive aspects. The micro‐invasive flapless surgical procedure might improve postoperative healing. Additionally, sufficient cooling of the bone might lead to less thermal affection of bone cells and less resorption of the cortical bone. However, systematic studies are needed to confirm the observations of the presented case report.
Additional details
Identifiers
- OpenAlex
- W3138833627
- PMID
- 33936701
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/ccr3.4046
Dates
- Issued
-
March 20, 2021
References
- Tolstunov, L., & Hicke, B. (2013). Horizontal Augmentation Through the Ridge-Split Procedure: A Predictable Surgical Modality in Implant Reconstruction. Journal of Oral Implantology, 39(1), 59–68. https://doi.org/10.1563/aaid-joi-d-12-00112
- Khairnar, M. S., Khairnar, D., & Bakshi, K. (2014). Modified ridge splitting and bone expansion osteotomy for placement of dental implant in esthetic zone. Contemporary Clinical Dentistry, 5(1), 110–114. https://doi.org/10.4103/0976-237x.128684
- Jawbone enlargement using immediate implant placement associated with a split‐crest technique and guided tissue regeneration
- Mestas, G., Alarcón, M., & Chambrone, L. (2016). Long-Term Survival Rates of Titanium Implants Placed in Expanded Alveolar Ridges Using Split Crest Procedures: A Systematic Review. The International Journal of Oral & Maxillofacial Implants, 591–599. https://doi.org/10.11607/jomi.4453
- Jensen, O. T., Cullum, D. R., & Baer, D. (2009). Marginal Bone Stability Using 3 Different Flap Approaches for Alveolar Split Expansion for Dental Implants—A 1-Year Clinical Study. Journal of Oral and Maxillofacial Surgery, 67(9), 1921–1930. https://doi.org/10.1016/j.joms.2009.04.017
- Jha, N., Choi, E. H., Kaushik, N. K., Ryu, J. J., & Mishra, Y. K. (2017). Types of devices used in ridge split procedure for alveolar bone expansion: A systematic review. PLOS ONE, 12(7), e0180342. https://doi.org/10.1371/journal.pone.0180342
- González-García, R., Monje, F., & Moreno, C. (2011). Alveolar split osteotomy for the treatment of the severe narrow ridge maxillary atrophy: a modified technique. International Journal of Oral and Maxillofacial Surgery, 40(1), 57–64. https://doi.org/10.1016/j.ijom.2010.03.030
- Reliability of bimaxillary surgical planning with the 3‐D orthognathic surgery simulator
- Schneider, M., Tzscharnke, O., Pilling, E., Lauer, G., & Eckelt, U. (2005). Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia. Journal of Cranio-Maxillofacial Surgery, 33(1), 8–12. https://doi.org/10.1016/j.jcms.2004.05.010
- Tonin, R. H., Iwaki Filho, L., Yamashita, A. L., Ferraz, F. W. da S., Tolentino, E. de S., Previdelli, I. T. dos S., Brum, B., & Iwaki, L. C. V. (2020). Accuracy of 3D virtual surgical planning for maxillary positioning and orientation in orthognathic surgery. Orthodontics & Craniofacial Research, 23(2), 229–236. https://doi.org/10.1111/ocr.12363
- Hu, P., Li, J., Du, W., Ji, H., Xu, C., & Luo, E. (2019). The Drilling Guiding Templates and Pre-Bent Titanium Plates Improves the Operation Accuracy of Orthognathic Surgery With Computer-Aided Design and Computer-Aided Manufacturing Occlusal Splints for Patients With Facial Asymmetry. Journal of Craniofacial Surgery, 30(7), 2144–2148. https://doi.org/10.1097/scs.0000000000005656
- Seeberger, R., Scherfler, S., Freier, K., & Thiele, O. (2011). Use of stereolithographic cutting guides in corrective (wedge) Lefort I osteotomy. British Journal of Oral and Maxillofacial Surgery, 49(5), e20–e21. https://doi.org/10.1016/j.bjoms.2010.09.010
- Sukegawa, S., Kanno, T., & Furuki, Y. (2018). Application of computer-assisted navigation systems in oral and maxillofacial surgery. Japanese Dental Science Review, 54(3), 139–149. https://doi.org/10.1016/j.jdsr.2018.03.005
- Li, B., Zhang, L., Sun, H., Yuan, J., Shen, S. G. F., & Wang, X. (2013). A novel method of computer aided orthognathic surgery using individual CAD/CAM templates: a combination of osteotomy and repositioning guides. British Journal of Oral and Maxillofacial Surgery, 51(8), e239–e244. https://doi.org/10.1016/j.bjoms.2013.03.007
- Computer‐aided design and computer‐aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom‐made implants: Which indications in orthognathic surgery?
- Alevizakos, V., Mitov, G., Stoetzer, M., & von See, C. (2019). A retrospective study of the accuracy of template-guided versus freehand implant placement: A nonradiologic method. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 128(3), 220–226. https://doi.org/10.1016/j.oooo.2019.01.009
- Effect of flapless surgery on pain experienced in implant placement using an image‐guided system
- Nickenig, H.-J., Wichmann, M., Hamel, J., Schlegel, K. A., & Eitner, S. (2010). Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method – a combined in vivo – in vitro technique using cone-beam CT (Part II). Journal of Cranio-Maxillofacial Surgery, 38(7), 488–493. https://doi.org/10.1016/j.jcms.2009.10.023
- Vermeulen, J. (2017). The Accuracy of Implant Placement by Experienced Surgeons: Guided vs Freehand Approach in a Simulated Plastic Model. The International Journal of Oral & Maxillofacial Implants, 32(3), 617–624. https://doi.org/10.11607/jomi.5065
- Liu, Y., Wu, J., Zhang, J., Peng, W., & Liao, W. (2016). Numerical and Experimental Analyses on the Temperature Distribution in the Dental Implant Preparation Area when Using a Surgical Guide. Journal of Prosthodontics, 27(1), 42–51. https://doi.org/10.1111/jopr.12488
- Lamazza, L., Garreffa, G., Laurito, D., Lollobrigida, M., Palmieri, L., & De Biase, A. (2016). Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone. BioMed Research International, 2016, 1–7. https://doi.org/10.1155/2016/6473680
- Matys, J., Flieger, R., & Dominiak, M. (2016). Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study. BioMed Research International, 2016, 1–8. https://doi.org/10.1155/2016/9654975
- Pellegrino, G., Bellini, P., Cavallini, P. F., Ferri, A., Zacchino, A., Taraschi, V., Marchetti, C., & Consolo, U. (2020). Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study. International Journal of Environmental Research and Public Health, 17(6), 2153. https://doi.org/10.3390/ijerph17062153
- Block, M. S., & Emery, R. W. (2016). Static or Dynamic Navigation for Implant Placement—Choosing the Method of Guidance. Journal of Oral and Maxillofacial Surgery, 74(2), 269–277. https://doi.org/10.1016/j.joms.2015.09.022
- Chiapasco, M., Abati, S., Romeo, E., & Vogel, G. (1999). Clinical outcome of autogenous bone blocks or guided bone regeneration with e‐PTFE membranes for the reconstruction of narrow edentulous ridges. Clinical Oral Implants Research, 10(4), 278–288. https://doi.org/10.1034/j.1600-0501.1999.100404.x
1–25 of 45
Citations
- https://doi.org/10.1111/cid.13363
- https://doi.org/10.1111/clr.14267
- Alevizakos, V., Mitov, G., Schiller, M., Bergmann, A.-L., Theis, L., & von See, C. (2023). Comparison of temperature changes in different irrigation methods used in guided piezosurgery: in vitro study. Oral and Maxillofacial Surgery, 28(2), 653–658. https://doi.org/10.1007/s10006-023-01183-1
- https://doi.org/10.1111/prd.12527