Published July 17, 2015 | Journal article | Version v1 | https://doi.org/10.1007/s00402-015-2285-8

Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures

Additional details

Dates

Issued
July 17, 2015

References

  1. WU, C.-C., & SHIH, C.-H. (1992). Simultaneous Bilateral Femoral Shaft Fractures. The Journal of Trauma: Injury, Infection, and Critical Care, 32(3), 289–293. https://doi.org/10.1097/00005373-199203000-00004
  2. Citak, M., Suero, E. M., O’Loughlin, P. F., Arvani, M., Hüfner, T., Krettek, C., & Citak, M. (2010). Femoral malrotation following intramedullary nailing in bilateral femoral shaft fractures. Archives of Orthopaedic and Trauma Surgery, 131(6), 823–827. https://doi.org/10.1007/s00402-010-1245-6
  3. Wolinsky, P. R., McCarty, E., Shyr, Y., & Johnson, K. (1999). Reamed Intramedullary Nailing of the Femur. The Journal of Trauma: Injury, Infection, and Critical Care, 46(3), 392–399. https://doi.org/10.1097/00005373-199903000-00007
  4. Winquist, R. A., Hansen, S. T., & Clawson, D. K. (2001). Closed Intramedullary Nailing of Femoral Fractures. The Journal of Bone and Joint Surgery-American Volume, 83(12), 1912. https://doi.org/10.2106/00004623-200112000-00021
  5. Goldring, S. R., Clark, C. R., & Wright, T. M. (1993). The problem in total joint arthroplasty. The Journal of Bone & Joint Surgery, 75(6), 799–801. https://doi.org/10.2106/00004623-199306000-00001
  6. Jaarsma, R. L., Pakvis, D. F. M., Verdonschot, N., Biert, J., & van Kampen, A. (2004). Rotational Malalignment After Intramedullary Nailing of Femoral Fractures. Journal of Orthopaedic Trauma, 18(7), 403–409. https://doi.org/10.1097/00005131-200408000-00002
  7. Tornetta, P., Ritz, G., & Kantor, A. (1995). Femoral Torsion after Interlocked Nailing of Unstable Femoral Fractures. The Journal of Trauma: Injury, Infection, and Critical Care, 38(2), 213–219. https://doi.org/10.1097/00005373-199502000-00011
  8. Krettek, C., Miclau, T., Gru¨n, O., Schandelmaier, P., & Tscherne, H. (1998). Intraoperative control of axes, rotation and length in femoral and tibial fractures technical note. Injury, 29, 29–39. https://doi.org/10.1016/s0020-1383(98)95006-9
  9. Kuo TY, Skedros JG, Bloebaum RD (2003) Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference. Invest Radiol 38:221–229
  10. Jaarsma, R. L., Verdonschot, N., van der Venne, R., & van Kampen, A. (2005). Avoiding rotational malalignment after fractures of the femur by using the profile of the lesser trochanter: an in vitro study. Archives of Orthopaedic and Trauma Surgery, 125(3), 184–187. https://doi.org/10.1007/s00402-004-0790-2
  11. Citak, M., Citak, M., Kendoff, D., O’Loughlin, P. F., Tavassol, F., Jagodzinski, M., Krettek, C., & Hüfner, T. (2009). Estimation of pretraumatic femoral antetorsion in bilateral femoral shaft fractures. Skeletal Radiology, 38(12), 1183–1187. https://doi.org/10.1007/s00256-009-0748-0
  12. Stübig, T., Min, W., Arvani, M., Hawi, N., Krettek, C., & Citak, M. (2011). Accuracy of measurement of femoral anteversion in femoral shaft fractures using a computer imaging software: a cadaveric study. Archives of Orthopaedic and Trauma Surgery, 132(5), 613–616. https://doi.org/10.1007/s00402-011-1450-y
  13. Suero, E. M., Hüfner, T., Stübig, T., Krettek, C., & Citak, M. (2010). Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury, 41(6), 589–591. https://doi.org/10.1016/j.injury.2009.10.053
  14. Jend, H.-H. (1986). Die computertomographische Antetorsionswinkelbestimmung. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 144(04), 447–452. https://doi.org/10.1055/s-2008-1048820
  15. Hawi, N., Kabbani, A., O'Loughlin, P., Krettek, C., Citak, M., & Liodakis, E. (2012). Intraoperative measurement of femoral antetorsion using the anterior cortical angle method: a novel use for smartphones. The International Journal of Medical Robotics and Computer Assisted Surgery, 9(1), 29–35. https://doi.org/10.1002/rcs.1464
  16. Weil, Y. A., Gardner, M. J., Helfet, D. L., & Pearle, A. D. (2007). Computer Navigation Allows for Accurate Reduction of Femoral Fractures. Clinical Orthopaedics & Related Research, 460, 185–191. https://doi.org/10.1097/blo.0b013e31804d2355
  17. Kendoff, D., Citak, M., Gardner, M. J., Gösling, T., Krettek, C., & Hüfner, T. (2007). Navigated Femoral Nailing Using Noninvasive Registration of the Contralateral Intact Femur to Restore Anteversion. Technique and Clinical Use. Journal of Orthopaedic Trauma, 21(10), 725–730. https://doi.org/10.1097/bot.0b013e31812f69a9

Citations

  1. Brühschwein, A., Schmitz, B., Zöllner, M., Reese, S., & Meyer-Lindenberg, A. (2023). Three-dimensional computed tomographic angular measurements of the canine tibia using a bone-centered coordinate system. Frontiers in Veterinary Science, 10. https://doi.org/10.3389/fvets.2023.1154144
  2. Brühschwein, A., Schmitz, B., Zöllner, M., Reese, S., & Meyer-Lindenberg, A. (2022). Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning. Frontiers in Veterinary Science, 9. https://doi.org/10.3389/fvets.2022.1019215
  3. Orfeuvre, B., Tonetti, J., Kerschbaumer, G., Barthelemy, R., Moreau-Gaudry, A., & Boudissa, M. (2021). EOS stereographic assessment of femoral shaft malunion after intramedullary nailing. A prospective series of 48 patients at 9 months’ follow-up. Orthopaedics & Traumatology: Surgery & Research, 107(2), 102805. https://doi.org/10.1016/j.otsr.2021.102805
  4. Orfeuvre, B., Tonetti, J., Kerschbaumer, G., Barthelemy, R., Moreau-Gaudry, A., & Boudissa, M. (2021). Évaluation stéréoradiographique EOS des cals vicieux diaphysaires fémoraux après enclouage centromédullaire. À propos d'une série prospective continue de 48 patients à 9 mois de recul. Revue de Chirurgie Orthopédique et Traumatologique, 107(2), 218–223. https://doi.org/10.1016/j.rcot.2021.01.005
  5. Degen, N., Suero, E., Bogusch, M., Neuerburg, C., Manz, K. M., Becker, C. A., Befrui, N., Kammerlander, C., Böcker, W., & Zeckey, C. (2020). Intraoperative use of cortical step sign and diameter difference sign: Accuracy, inter-rater agreement and influence of surgical experience in subtrochanteric transverse fractures. Orthopaedics & Traumatology: Surgery & Research, 106(4), 639–644. https://doi.org/10.1016/j.otsr.2020.01.015
  6. Weidert, S., Wang, L., Landes, J., Sandner, P., Suero, E. M., Navab, N., Kammerlander, C., Euler, E., & von Der Heide, A. (2019). Video‐augmented fluoroscopy for distal interlocking of intramedullary nails decreased radiation exposure and surgical time in a bovine cadaveric setting. The International Journal of Medical Robotics and Computer Assisted Surgery, 15(4), Article e1995. https://doi.org/10.1002/rcs.1995
  7. Liodakis, E., Bruns, N., Macke, C., Krettek, C., & Omar, M. (2019). 3D-Druck-Template-gestützte Reposition von Frakturen der langen Röhrenknochen. Der Unfallchirurg, 122(4), 286–292. https://doi.org/10.1007/s00113-019-0627-7
  8. Krettek, C., & Bruns, N. (2019). Aktueller Stand und neue Entwicklungen des 3D-Drucks in der Unfallchirurgie. Der Unfallchirurg, 122(4), 256–269. https://doi.org/10.1007/s00113-019-0636-6
  9. Vanhove, F., Noppe, N., Fragomen, A. T., Hoekstra, H., Vanderschueren, G., & Metsemakers, W.-J. (2019). Standardization of torsional CT measurements of the lower limbs with threshold values for corrective osteotomy. Archives of Orthopaedic and Trauma Surgery, 139(6), 795–805. https://doi.org/10.1007/s00402-019-03139-1
  10. Zeckey, C., Bogusch, M., Borkovec, M., Becker, C. A., Neuerburg, C., Weidert, S., Suero, E. M., Böcker, W., Greiner, A., & Kammerlander, C. (2018). Radiographic cortical thickness parameters as predictors of rotational alignment in proximal femur fractures: A cadaveric study. Journal of Orthopaedic Research, 37(1), 69–76. https://doi.org/10.1002/jor.24166
  11. Omar, M., Zeller, A., Gellrich, N., Rana, M., Krettek, C., & Liodakis, E. (2017). Application of a customized 3D printed reduction aid after external fixation of the femur and tibia: Technical note. The International Journal of Medical Robotics and Computer Assisted Surgery, 13(4), Article e1803. https://doi.org/10.1002/rcs.1803
  12. Suero, E. M., Hartung, T., Westphal, R., Hawi, N., Liodakis, E., Citak, M., Krettek, C., & Stuebig, T. (2017). Improving the human–robot interface for telemanipulated robotic long bone fracture reduction: Joystick device vs. haptic manipulator. The International Journal of Medical Robotics and Computer Assisted Surgery, 14(1), Article e1863. https://doi.org/10.1002/rcs.1863
  13. Suero, E. M., Westphal, R., Citak, M., Stueber, V., Lueke, U., Krettek, C., & Stuebig, T. (2017). Repeatability and reproducibility of a telemanipulated fracture reduction system. Journal of Robotic Surgery, 12(3), 409–416. https://doi.org/10.1007/s11701-017-0749-2
  14. Ramme, A. J., Egol, J., Chang, G., Davidovitch, R. I., & Konda, S. (2017). Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?. Injury, 48(7), 1603–1608. https://doi.org/10.1016/j.injury.2017.03.041
  15. Memarzadeh, A., Tissingh, E. K., Hull, P., & Trompeter, A. (2017). Intramedullary nailing of femoral shaft fractures in adults. Orthopaedics and Trauma, 31(2), 86–92. https://doi.org/10.1016/j.mporth.2016.11.001