Functional Aspects of the Eustachian Tube by Means of 3D-Modeling
Authors/Creators
- 1. MHH, Hannover, Germany
- 2. HörSys GmbH, Hannover, Germany
Description
Histological and radiological data of an Eustachian tube from a blackface sheep This data repository is accompanying the publication "Functional aspects of the Eustachian tube by means of 3D-modeling" Robert Schuon, Josef Schwarzensteiner, Gerrit Paasche, Thomas Lenarz, Samuel John Published: August 12, 2021 https://doi.org/10.1371/journal.pone.0244909 This README.md describes the data set of one black face sheep Eustachian tube, cutted into histologic slices plus a dvt scan. For contacting the authors, please refer to the publication. We recommend to download 3DSlicer and load the .mrb file to get everything (histo and segmentation) merged, aligned and registered. But the raw data, measurements, raw segmentations are available, too. The work was part of the dissertation of Josef Schwarzensteiner. The "Testprobe001" is from the animal "Miss whooly 8". It contains histological cut images of the area of the Eustachian tube of a black face sheep and a CT scan of that sample. We made an effort to align the cut images correctly and provide the raw microscopic images, (raw_Testprobe001_block_I.zip and raw_Testprobe001_block_II.zip), including the retouched images (exposure normalization), the segmentations in ImageJ and the measured heights after cutting each slice. the aligned images (histological slices) and retouched versions thereof for both blocks (I and II) such that they stack up naturally → slices_aligned_block_I_and_II_retouched.zip the aligned labels (segmentations) of both blocks (I and II) such that they stack up naturally → labels_aligned_block_I_and_II.zip The full 3DSlicer scene including the histo cutslices aligned and the DVT registered onto each other based on the cannulas pierced through the specimen. 3DSlicer_fused_szene_all-in-one.mrb Note, the DVT was only available for one of the two blocks that made up the Testprobe001 specimen. 3D slicer scenes that contain the aligned volume data sets of microscopic images and DVT images. The plots are in plots_Testprobe001.zip. The file measurements_and_plotting.zip contains the measured heights of the lumen and the lengths of the cartilage as XLSX files and also generates plots. We used zip files because up to today zenodo does not support directory structures. For technical reasons in cutting the specimen, the "Testprobe001" was cut into two blocks that had to be combined digitally in order to form a coherent volume. We used the following software: read_roi v1.0 https://github.com/bnoi/read_ro to read .roi files from imagej → find it in read_roi.zip euclid3 own extension based on http://partiallydisassembled.net/euclid.html v0.01 → find it in euclid3.zip 3dSlicer The block was split into two parts "block I" and "block II". We only have a DVT from block II.
Additional details
Identifiers
Related works
- Is version of
- 10.5281/zenodo.5102631 (DOI)
Dates
- Issued
-
July 14, 2021